background image

 

- 3 - 

Steady on 

-Indicates a fault condition e.g. RF signal not being received 

 

Red LED 

Slowly pulsing 

-Indicates a valid install code has been received 

 

Green LED 

Steady on 

-Indicates a demand for heat 

 

Green LED 

Off 

 

- i.e. Heating satisfied 

 

Checking the hard wired circuit 

1.  Apply power to the TLX 1206 receiver. Ensure any Separate programmer in the heating circuit is calling for heat. The Red LED 

should be OFF 

2.  Press the TEST button. The Green LED should come on. Check that the boiler and/or motorised valve have operated. Remember 

to allow adequate time for the valve to open. Press TEST button again. The Green LED should go out, closing any valve and 
switching off the boiler. 
 
Note: TEST mode will automatically switch off after 15 minutes. 
 

Checking the RF circuit 
 

ENSURE THE RED AND GREEN LIGHTS ON THE RECEIVER ARE OFF PRIOR TO INSTALLING CODE 
 

1.  Press and hold the + and – buttons on the TLX 7506 for at least 3 seconds. The TLX 7506 will then transmit its unique digital 

security code every 10 secs. for the next 5 mins. The display will show flashing ‘ ] ]‘ while this is happening. 

2.  Within the 5 minute period, go to the TLX 1206 rf receiver. Press and hold the INSTALL button and then press the TEST  

button whie the install button is held. This will clear out any previously installed codes. The RED LED will pulse slowly for 3 
seconds to indicate this has been done. 

3.  Next, place the receiver in INSTALL mode by pressing and holding the INSTALL button (for at least 10 secs) The RED LED  

will come on and stay on until a valid INSTALL code has been received. When this happens, the RED LED will start  pulsing 
slowly and the INSTALL  button can be released. The RED LED will pulse for a further 3 seconds and then go off. The 
INSTALL code has been successfully received. 

4.  Go to the thermostat transmitter and press any key to stop the transmission. The display will stop transmitting ‘] ] ‘ and return 

to normal. 

5.  The TLX 1206 RF receiver will now only respond to radio signals with the installed code. I.E. from the TLX 7506 thermostat 

just installed. Even if the power is removed from the receiver it will not  forget the installed code. 

6.  Check that the TLX 7506 and the TLX 1206 are  

Communicating with each other by adjusting the TLX 7506 Set Point below and then above the actual temperature, thus 
generating a radio signal requesting the heat to come on or go off and check that the boiler responds as expected. The RED 
LED on the receiver will flash for 3 seconds each time a radio signal is received. This will happen every time the TLX 7506 
thermostat calls for the heating to be switched on or off. 

7.  The TLX 7506 thermostat also sends a radio signal  

Every 5 minutes to make sure that the TLX 1206 receiver knows what state it should be in. Therefore every 5 minutes the 
RED LED will flash for 3 seconds. If the TLX 1206 does not receive regular RF signals, the RED LED will come on indicating 
that a fault condition has occurred and the heating system will be switched OFF. 
 

NOTE. If more than one Radio Controlled Digital Room thermostat system is fitted within the same property, it is 
important that the above procedure is used to install each Room Thermostat in turn so that they are correctly 
matched to the relevant Receivers. 
 

        
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

N      L      1      2      3      4  

Com  On  Off 

Schematic for  
TLX 1206 

Содержание TLX 7506

Страница 1: ...a temperature that is reasonable for the whole house If you do have TRVs you can choose a slightly higher setting to make sure that even the coldest room is comfortable then prevent any overheating in other rooms by adjusting the TRVs Room thermostats need a free flow of air to sense the temperature so they must not be covered by curtains or blocked by furniture Nearby electric fires televisions w...

Страница 2: ...ce the batteries the following procedure should be carried out The thermostat should be isolated from the mains before proceeding 1 Remove the unit from the wall plate by sliding upwards and gently pulling away from the wall Slacken the retaining screw on the unit and open by hinging upwards along the top of the unit 2 Carefully remove batteries from the battery compartment and fit two new AA alka...

Страница 3: ...s been received When this happens the RED LED will start pulsing slowly and the INSTALL button can be released The RED LED will pulse for a further 3 seconds and then go off The INSTALL code has been successfully received 4 Go to the thermostat transmitter and press any key to stop the transmission The display will stop transmitting and return to normal 5 The TLX 1206 RF receiver will now only res...

Страница 4: ...e display will revert back to actual temperature To change the SET POINT I e the temperature requested press and hold the SET button and at the same time press or to increase or decrease the temperature setting The display will continue to show the SET POINT until the SET button is released The display will then show actual temperature When the TLX 7506 instructs your heating system to switch on A...