Description / Overview

The HeatMax™  RF  dial  thermostat  is  an
electronic  thermostat  designed  for  use
with  warm  water  underfloor  heating
systems.

��

  Comfort  operating  mode  (Day  time

use)

��

  Reduced  operating  mode  (Night

setback)

��

  Automatic 

Night 

setback  (in

conjunction with HeatMax™ RF night
set back timer module)

��

  Maximum 

and 

minimum

temperature  settings  limited  by
movable pins

How it works

The  HeatMax™  RF  dial  thermostat  is  a
state of the art, silent thermostat  with a
clear readable dial that lets you control the
way you like your home heated.

If the room air temperature is below the
current  set  temperature,  it  “calls  for
heat”,and  this  output  is  sent  to  the  UFH
wiring  centre,  which  controls  the  pump
and the boiler.

Similarly, once the room has been heated
and the  set temperature is  reached,  this
output  ends  and  the  corresponding
heating  zone  valve  will  close.  If  all
thermostats  on  the  system  are  satisfied,
both the pump and boiler will shut down.

An LED indicator tells you the thermostats
status.

Installation

Tools required

1.

Phillips Screwdriver (for cover removal
or replacement)

2.

Slotted  Screwdriver  with  a  2.5mm  or
3.0mm  blade  (for  receiver  terminal
connections)

3.

Screwdriver  to  suit  mounting  screws
(not supplied)

Step by step guide

1.

Remove battery protection strips

2.

Configure  thermostat  with  receiver
(see section following)

3.

Note position of dial before removing.
Gently  lever  off  the  dial  of  the
thermostat from its shaft

4.

Using  the  Phillips  screwdriver  undo
the screw located in the central hole

5.

The  two  parts  of  the  thermostat  can
now be separated

6.

Mount the backing plate on the wall at
your selected thermostat position

7.

Replace the face of the thermostat on
to the mounting plate and secure with
the screw

8.

Replace the dial on to the shaft in the
original  position  and  press  gently  to
the face of the thermostat.

NOTE:

Ensure that the thermostat

✓ 

 Is not higher than 1.5m from

the floor

✓ 

 Is at least 200mm away from

the edge of a door

✓ 

 Not in direct sunlight

✓ 

 Not next to a window

✓ 

 Not over a heat source

Set-up / Commissioning

Radio Configuration Mode

Install and wire in the receiver, set the RF
Initiation  mode.  (You  have  30  seconds  to
execute the next step)

To  assign  a  HeatMax™  RF  dial  thermostat
to the receiver put the switch from the

OFF position to the 

Comfort position.

The  HeatMax™ RF dial thermostat will send
a  configuration  address  by  radio  signal  to
the receiver.

Verify  that  radio  signals  are  correctly
received. On the receiver the Green LED will
blink at each radio signal received from the
thermostat.

When the thermostat is configured. Set
the receiver to Auto mode.

Calibration of thermostat:

This  is  only  to  be  carried  out  if
recalibration 

is 

required. 

The

thermostats 

are 

set 

during

manufacturing.

Remove the dial and divide parts (2) &
(3)

Put  the  bottom  part  (2)  back  on  the
shaft

Turn the part (2) until you have the led
shining  in  limit  position.  (Check  with
external thermometer)

Then  put  the  dial  (3)  back  in  correct
position

Pins  (1)  can  be  used  to  set  the
minimum 

and 

maximum

temperature  using  the  holes  around
(2)

NOTE:

✓ 

 While setting the thermostat

should be near the receiver

3