When using the GBL-4DBT grounding lug, assemble the grounding lug to
aluminum frame using stainless steel M5 screw and hardware as shown above.The
star washer is fitted directly under the grounding lug and makes electrical contact
by penetrating the anodized coating of the aluminum frame; the screw assembly a
future fitted with a flat washer, then a split lock washer finally a nut to secure the entire
assembley (see the picture above). Recommended M5 screw assembly torque is 1.5N-m.
Next insert the ground wire (10-12 AWG exposed copper wire is recommended) to the
feet of the lug, and screw down the slotted screw. Be carerful not to damage the wire
core.
•
For more information, please contact supplier: ILSCO, http://www.ilsco.com
To ensure optimum module performance, Suntech recommends the following
maintenance measures:
•
Clean the module minimum once a year or more often when required depending
of the pollution. Remove all organic from the surface. Module with soiling or
contamination may reduce the power generation of the system. Always use clean
water and a soft non-abrasive sponge or cloth for cleaning. A mild, non-abrasive
cleaning agent may be used to remove stubborn dirt.
•
Uncontrolled pollution is voiding the warranty or not cleaning the modules in time
voids the warranty.
•
Check the electrical, grounding and mechanical connections every six months to
verify that they are clean, secure,undamaged and free of corrosion. Or else the warranty
may be voided.
•
In the event of a ground fault condition, NEVER wash or spray modules with water
until ground fault has been identified, corrected by an authorized solar inverter service
technician and the inverter is fully operational. This can cause electrocution or a serious
safety issue.
•
If any problem arises, consult a professional solar service providers for suggestions.
•
Caution: observe solar manufacturers' maintenance instructions for all components
used in the system, such as support frames, charging regulators, inverters, batteries etc.
Maintenance
No.14
No.15
Wuxi Suntech Power Co., Ltd.
Address: No.9 Xinhua Road, New District Wuxi, China 214028
Customer Service Hot Line: +86 400 8888 009 Fax: +86 510 8534 3321
E-mail: [email protected]
Or please contact our local representatives, details at www.suntech-power.com
No.16
No.15
T series - 1324 mm×992 mm×35 mm
Module
Optimum
Operating
Voltage
(Vmp) at
STC, (V dc)
Optimum
Operating
Current
(Imp) at
STC, (A dc)
Open
Circuit
Voltage
(Voc) at
STC, (V dc)
Short
Circuit
Current
(Isc) at
STC, (A dc)
Maximum
Power
(Pmax) at
STC,
(Watts)
Maximum
System
Voltage
(IEC/UL)
Maximum
Series
Fuse
Rating
STP225S-16/Tem
25.2
8.93
31.4
9.41
225
1000/600
20
STP220S-16/Tem
24.9
8.84
31.1
9.34
220
1000/600
20
STP215S-16/Tem
24.6
8.75
30.8
9.28
215
1000/600
20
STP210S-16/Tem
24.3
8.65
30.5
9.22
210
1000/600
20
STP205S-16/Tem
24.0
8.55
30.2
9.16
205
1000/600
20
STP200S-16/Tem
23.7
8.45
29.5
9.01
200
1000/600
20
STP185S-16/Tem
22.8
8.12
29.1
8.92
185
1000/600
20