Version 20150101
Version 20150101
No.5
2. Barcode: each individual module has a unique serial number. The serial number has
18 digits. The 15th and the 16th digits are the week code, and the 17th and the 18th
digits are the year code. For example, STP xxxxxxxxxxxxxx2414 means the module was
assembled and tested in the 24th week of 2014. Each module has only one bar code. It
is permanently attached to the interior of the module and is visible from the top front
of the module. This bar code is inserted prior to laminating.
Typical serial number barcode label
Do not remove any labels. Removing a label will make the Suntech warranty void.
3. Sorting label: four different marks are shown on this sticker. "QC Pass" assures that
the module has passed the quality control examination. "HIPOT" means that it has
passed the insulation test. Finally modules are sorted out according to their output
current, referred as a corresponding symbol "Ix" attached, in which x takes the value
1, 2 or 3(I3 marks physically the highest current). To get optimal performance out of a
string of modules it is recommended to connect only modules of the same "Ix" class (for
example only I2 modules) in one given string. The function of the "Barcode" please refer
to the "Barcode" instruction mentioned above.
Sorting label
Purpose of this guide
Product identification
•
Never open electrical connections or unplug connectors while the circuit is under
load.
•
Contact with electrically charged parts of the modules, such as terminals, can
result in burns, sparks and lethal shock whether or not the module is connected.
•
Do not touch the PV module unnecessarily during installation. The glass surface
and the frame may be hot; there is a risk of burns and electric shock.
•
Do not work in the rain, snow or in windy conditions.
•
Avoid exposing cables and connectors to direct sunlight and scratches or cuts in
order to prevent insulation degradation.
•
Use only insulated tools that are approved for working on electrical installations.
•
Keep children well away from the system while transporting and installing
mechanical and electrical components.
•
Completely cover the module with an opaque material during installation to
prevent electricity from being generated.
•
Do not wear metallic rings, watchbands, earrings, nose rings, lip rings or other
metallic objects while installing or troubleshooting photovoltaic systems.
•
Follow the safety regulations(eg. safety rules for working on electrical power
plant stations) of your regions and for all other system components, including wires
and cables, connectors, charging regulators, inverters, storage batteries, rechargeable
batteries, etc.
•
Under normal conditions, a photovoltaic module is likely to experience conditions
that produce more current and/or voltage than reported at standard test conditions.
Accordingly, the values of Isc and Voc marked on this module should be multiplied by a
factor of 1.25 when determining component voltage ratings, conductor current ratings,
minimum factor of fuse sizes, and size of controls connected to the PV output.
•
Only use same connectors to connect modules to form a string, or connect to
another device. Removing the connectors will void the warranty.
Fire Safety
•
Consult your local authority for guidelines and requirements for building or
structural fire safety.
•
Roof constructions and installations may affect the fire safety of a building;
improper installation may create hazards in the event of a fire.
•
Use components such as ground fault circuit breakers and fuses as required by
local authority.
•
Do not use modules near equipment or in places where flammable gases may be
generated.
•
The modules have been rated Fire Class C, and are suitable for mounting on to a
Class A roof.
No.4
Each module has three labels providing the following information:
1. Nameplate: describes the product type; rated power, rated current, rated voltage,
open circuit voltage, short circuit current, all as measured under standard test
conditions; weight, dimensions etc.; the maximum system voltage is 600 volts or 1000
volts depending on the product family DC for UL standard and 1000 volts DC for IEC
standard. Depending on the products some are UL/IEC listed to 1 000 volts while other
UL products are 600 volts. Check your nameplate or contact your local representative
for details.
Installation safety
Содержание STP185S-16/Tem