background image

Version  20150101

Version  20150101

W series - 1640 mm×992 mm×35 mm

Module

Optimum

Operating

Voltage

(Vmp) at

STC, (V dc)

Optimum

Operating

Current
(Imp) at

STC, (A dc)

Open

Circuit

Voltage
(Voc) at

STC, (V dc)

Short

Circuit

Current

(Isc) at

STC, (A dc)

Maximum

Power

(Pmax) at

STC, 

(Watts)

Maximum

System

Voltage

(IEC/UL)

Maximum

Series

Fuse

Rating

STP260-20/Wd

30.9

8.42

37.7

8.89

260

1000/600

20

STP255-20/Wd

30.8

8.28

37.6

8.76

255

1000/600

20

STP250-20/Wd

30.7

8.15

37.4

8.63

250

1000/600

20

STP245-20/Wd

30.5

8.04

37.3

8.52

245

1000/600

20

STP240-20/Wd

30.2 

7.95

37.2

8.43

240

1000/600

20

STP265S-20/Wd

31.0

8.55

37.8

9.01

265

1000/600

20

STP260S-20/Wd

30.9

8.42

37.7

8.89

260

1000/600

20

STP255S-20/Wd

30.8

8.28

37.6

8.76

255

1000/600

20

STP250S-20/Wd

30.7

8.15

37.4

8.63

250

1000/600

20

STP245S-20/Wd

30.5

8.04

37.3

8.52

245

1000/600

20

STP240S-20/Wd

30.2

7.95

37.2

8.43

240

1000/600

20

STP265S-20/Wdb

31.0

8.55

37.8

9.01

265

1000/600

20

STP260S-20/Wdb

30.9

8.42

37.7

8.89

260

1000/600

20

STP255S-20/Wdb

30.8

8.28

37.6

8.76

255

1000/600

20

STP250S-20/Wdb

30.7

8.15

37.4

8.63

250

1000/600

20

STP245S-20/Wdb

30.5

8.04

37.3

8.52

245

1000/600

20

STP240S-20/Wdb

30.2

7.95

37.2

8.43

240

1000/600

20

STP235S-20/Wdb

30.2

7.79

37.0

8.35

235

1000/600

20

STP260-20/Wds

30.9

8.42

37.7

8.89

260

1000/600

20

STP255-20/Wds

30.8

8.28

37.6

8.76

255

1000/600

20

STP250-20/Wds

30.7

8.15

37.4

8.63

250

1000/600

20

STP245-20/Wds

30.5

8.04

37.3

8.52

245

1000/600

20

STP240-20/Wds

30.2

7.95

37.2

8.43

240

1000/600

20

STP265-20/Wem

31.0

8.56

37.8

9.02

265

1000/600

20

STP260-20/Wem

30.9

8.42

37.7

8.89

260

1000/600

20

STP255-20/Wem

30.8

8.28

37.6

8.76

255

1000/600

20

STP250-20/Wem

30.7

8.15

37.4

8.63

250

1000/600

20

STP275S-20/Wem

31.1

8.85

38.5

9.34

275

1000/600

20

STP270S-20/Wem

30.8

8.77

38.3

9.28

270

1000/600

20

STP265S-20/Wem

30.5

8.69

38.1

9.22

265

1000/600

20

STP260S-20/Wem

30.2

8.61

37.9

9.17

260

1000/600

20

No.17

No.16

No.17

V series  - 1956 mm×992 mm×40 mm 

Module

Optimum

Operating

Voltage

(Vmp) at

STC, (V dc)

Optimum

Operating

Current

(Imp) at

STC, (A dc)

Open

Circuit

Voltage

(Voc) at

STC, (V dc)

Short

Circuit

Current

(Isc) at

STC, (A dc)

Maximum

Power

(Pmax) at

STC, 

(Watts)

Maximum

System

Voltage

(IEC/UL)

Maximum

Series

Fuse

Rating

STP310-24/Ve

36.5

8.50

44.9

8.96

310

1000/600

20

STP305-24/Ve

36.2

8.43

44.7

8.89

305

1000/600

20

STP300-24/Ve

35.9

8.36

44.5

8.83

300 

1000/600

20

STP295-24/Ve

35.6

8.29

44.3

8.74

295

1000/600

20

STP290-24/Ve

35.4

8.20

44.1

8.65

290

1000/600

20

STP310-24/Vd

36.5

8.50

45.4

8.85

310

1000/600

20

STP305-24/Vd

36.3

8.41

45.3

8.74

305

1000/600

20

STP300-24/Vd

36.1

8.32

45.2

8.65

300

1000/600

20

STP295-24/Vd

35.7

8.27

45.1

8.57

295

1000/600

20

STP290-24/Vd

35.6

8.15

45.0

8.42

290

1000/600

20

STP285-24/Vd

35.4

8.06

44.9

8.37

285

1000/600

20

STP280-24/Vd

35.2

7.95

44.8

8.33

280

1000/600

20

STP275-24/Vd

35.1

7.84

44.7

8.26

275

1000/600

20

STP270-24/Vd

35.0

7.71

44.5

8.20

270

1000/600

20

STP260-24/Vd

34.8

7.47

44.0

8.09

260

1000/600

20

STP315-24/Vem

36.8

8.56

45.1

9.02

315

1000/600

20

STP310-24/Vem

36.5

8.50

44.9

8.96

310

1000/600

20

STP305-24/Vem

36.2

8.43

44.7

8.89

305

1000/600

20

STP300-24/Vem

35.9

8.36

44.5

8.83

300

1000/600

20

No.20

Содержание STP185S-16/Tem

Страница 1: ......

Страница 2: ... General installation Installation method Attachment guidelines 11 Electrical Installation General installation Grounding 14 Maintenance No 1 Global Installation Guide for Suntech Power Photovoltaic Module Version 20150101 Please read carefully This document is binding for any warranty case Any installed PV system less than 500m from coastline please refer to the Near coast installation manual ...

Страница 3: ...d to as module Wuxi Suntech Power Co Ltd referred to as Suntech Installers must read and understand this guide prior to installation For any questions please contact Suntech s Global Quality Customer Support department or our local representatives for more detailed information Installers must follow all safety precautions as described in this guide as well as local requirement and regulations by l...

Страница 4: ...ling mechanical and electrical components Completely cover the module with an opaque material during installation to prevent electricity from being generated Do not wear metallic rings watchbands earrings nose rings lip rings or other metallic objects while installing or troubleshooting photovoltaic systems Follow the safety regulations eg safety rules for working on electrical power plant station...

Страница 5: ... of 10 cm between the roof plane and the frame of the module is generally recommended Always observe the instructions and safety precautions included with the module support frames No 6 This installation manual is applicable for all pv system of 500 m or more away from the coastline If you need to install your system less than 500m from the coast line please refer to Near coast installation manual...

Страница 6: ...es W series V series module No 9 2400 Pa Load 2400 Pa Wind Load 2400 Pa Snow Load 3800 Pa Load 3800 Pa Wind Load 3800 Pa Snow Load 5400 Pa Load 5400 Pa Snow Load 3800 Pa Wind Load Mounting system Clamping system Attachment to the long frame Length Use four clamps Use four clamps Use six clamps Clamping system Attachment to the short frame Use four clamps on short frame Use four clamps on the short...

Страница 7: ... void the warranty It is not recommended to use modules with different configurations grounding wiring in the same system Excessive cables must be organized or fixed in an adequate way e g attached to the mounting structure by using non metallic cable ties Solar cables connectors and juction boxes should not be exposed to water exposure and snow and rain or water submersion for a long period of ti...

Страница 8: ...al hand over to the owner including an installation protocol is required Provide a clear documentation of the system to the owner consisting of following minimum data such as user guide system layout data sheets performance expectations electrical system data e g a copy of the installation test report following minimum requirements of IEC 62446 IEC 60364 6 Grounding For grounding and bonding requi...

Страница 9: ...ix months to verify that they are clean secure undamaged and free of corrosion Or else the warranty may be voided In the event of a ground fault condition NEVER wash or spray modules with water until ground fault has been identified corrected by an authorized solar inverter service technician and the inverter is fully operational This can cause electrocution or a serious safety issue If any proble...

Страница 10: ... 1000 600 20 STP265 20 Wem 31 0 8 56 37 8 9 02 265 1000 600 20 STP260 20 Wem 30 9 8 42 37 7 8 89 260 1000 600 20 STP255 20 Wem 30 8 8 28 37 6 8 76 255 1000 600 20 STP250 20 Wem 30 7 8 15 37 4 8 63 250 1000 600 20 STP275S 20 Wem 31 1 8 85 38 5 9 34 275 1000 600 20 STP270S 20 Wem 30 8 8 77 38 3 9 28 270 1000 600 20 STP265S 20 Wem 30 5 8 69 38 1 9 22 265 1000 600 20 STP260S 20 Wem 30 2 8 61 37 9 9 17...

Отзывы: