Doc. Title
Author
Page of Pages
ST300/340 OPERATION MANUAL
– LATAM
HG.Park
79 of 146
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.41
26 May. 2015
Suntech International Ltd.
Confidential Document
ST300P
ST300F
HDR
HDR
DEV_ID
DEV_ID
MODEL
MODEL
SW_VER
SW_VER
DATE
DATE
TIME
TIME
CELL
CELL
LAT
LAT
LON
LON
SPD
SPD
CRS
CRS
SATT
SATT
FIX
FIX
DIST
DIST
PWR_VOLT
PWR_VOLT
I/O
I/O
ALERT_ID
ALERT_ID
H_METER
H_METER
BCK_VOLT
BCK_VOLT
MSG_TYPE
MSG_TYPE
TPS_IN
ADC
TPS_OUT
FUEL1
FUEL2
6-4-1. Normal
Field
Marks
Meaning
HDR
“ST300ALT” Alert report header.
DEV_ID
9 char
Device ID.
MODEL
2 char
Device Model (According to table model).
SW_VER
3 char
Software Version.
DATE
8 char
GPS date (yyyymmdd).
TIME
8 char
GPS time (hh:mm:ss).
CELL
String
Location Code ID(3 digits hex) + Serving Cell BSIC(2 digits decimal).
LAT
String
Latitude (+/-xx.xxxxxx).
LON
String
Longitude (+/-xxx.xxxxxx).
SPD
String
Speed in km/h.
CRS
String
Course over ground in degree.
SATT
String
Number of satellites.
FIX
‘1’ or ‘0’
GPS is fixed (1); GPS is not fixed (0).
DIST
String
Traveled distance in meter.
PWR_VOLT
String
Voltage value of main power.
I/O
6 char
Current I/O status of inputs and outputs
Ig Input 2 + Input 3 + Out1 + Out2.
Ignition:
‘1’ (ON), ‘0’ (OFF).
Input1 ~ Input3:
‘1’ (Ground, Shorted), ‘0’ (Opened).
Out1 ~ Out2:
‘1’ (Active), ‘0’ (Inactive).