![SunTech ST300 Series Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/suntech/st300-series/st300-series_operation-manual_1400856046.webp)
Doc. Title
Author
Page of Pages
ST300/340 OPERATION MANUAL
– LATAM
HG.Park
46 of 146
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.41
26 May. 2015
Suntech International Ltd.
Confidential Document
4-16-1-2. How to set Polygon Position (Sequential Command - Middle)
Field
Marks
Value
Meaning
HDR
“ST300PLG”
Command type
DEV_ID
String
Device ID
VER
“02”
Protocol Version
CMD_NO
‘2’ ~
Sequential number of a series of commands
TOTAL_CMD_NO
Total number of the series of commands
GROUP_ID
‘1’ ~ ‘10’
Polygon group ID
LONGITUDE1
Longitude
LATITUDE1
Latitude
LONGITUDE2
Longitude
LATITUDE2
Latitude
…
…
LONGITUDE5
Longitude
LATITUDEN5
Latitude
4-16-1-3. How to set Polygon Group Enable/Disable (Sequential Command - Last)
Field
Marks
Value
Meaning
HDR
“ST300PLG”
Command type
DEV_ID
String
Device ID
VER
“02”
Protocol Version
CMD_NO
‘1’ ~
Sequential number of a series of commands
TOTAL_CMD_NO
Total number of the series of commands
GROUP_ID
‘1’ ~ ‘10’
Polygon group ID
ENABLE
‘0’ or ‘1’
Enable of the polygonal geo-fence group
<Note> :
This command can be sent independently to change enable/disable state.
In this case, both CMD_NO and TOTAL_CMD_NO is
‘1’
[command] ST300PLG;850000;02;
1;1
;1;0