Doc. Title
Author
Page of Pages
ST300/340 OPERATION MANUAL
– LATAM
HG.Park
18 of 146
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.41
26 May. 2015
Suntech International Ltd.
Confidential Document
IN3_TYPE
‘0’ ~ ‘15’
In case of 300V, 300R, 300A, 300F, 300H, 300C, 300K :
0 = Falling Edge.
1 = Rising Edge.
2 = Both Edge (Falling & Rising).
3 = Panic Button.
4 = Call1 Button.
5 = Call 2 Button.
6 = ADC.
7 = Anti-Theft Button.
11 = Door Sensor.
13 = Disable Immobilizer if it’s activated by Jammer
Detector.
15 = Anti-Theft Button 2.
Default = ‘2’.
Only the device that includes voice option (audio circuit) can
be set to
‘Call1 Button’ or ‘Call2 Button’.
In case of 300P
14 = TPS (works only on ST300P, fixed to the input2)
In case of 300A , 300H
17 = Hmeter (For more detail, please refer to
“Note” written
on the bottom of this table.
Others :
Same as IN1_TYPE.
Default = ‘2’.
IN1_CHAT
String
100ms
Input1 chattering time:
Range: 0 ~ 9999.
Default = 3 sec.
If 0, Input1 is not checked.
You should set this value to
‘1’, if Input1 Type is set to ‘Use
Coin Machine
’.
IN2_CHAT
String
100ms
Input2 chattering time:
Range: 0 ~ 9999.
Default = 2 sec.
If
‘0’, the input2 is not checked.
IN3_CHAT
String
100ms
Input3 chattering time:
Range: 0 ~ 9999.
Default = 2 sec.
If
‘0’, the input3 should not be set.