background image

 

 

7.  [TIMER]  

Programmable time switch with start and residual time 

 

Starting time: This function is used to switch on the TRANSFORM unit automatically when the time 
entered has expired. Proceed as follows: 

 

a) Press [TIMER] switch in Stand-by (TRANSFORM unit is connected but not in operation), to enter the 
required number of hours after which the TRANSFORM unit is to start. 
b) Select the required function (cooling, heating, dehumification) and set the required temperature. 

 

c) When the set number of hours has expired, theTRANSFORM unit starts automatically.  
 
If you press the [POWER] switch before the time has expired, the time programming is deleted, the 
TRANSFORM unit switches on and can be operated in the required operating mode. 

 
 

Residual time: This function is used to automatically deactivate the TRANSFORM unit when the time 
entered has expired. Proceed as follows: 
a) Press the [TIMER] switch during operation and enter the required number of hours after which the 
TRANSFORM unit is to switch off. 
b) After the flashing of the number of hours on the LED has stopped, you can select the required 
function (cooling, heating, dehumification) and the required temperature. 

 

c) When the set number of hours has expired, the TRANSFORM unit switches on automatically. 
 
If you press the [POWER] switch before the time has expired, the Timer programming is deleted and 
the TRANSFORM unit switches off. 
 

8.  [SLEEP]  

Using this key you can set the sleep function of the TRANSFORM unit. The microprocessor integrated 
in the TRANSFORM unit will raise the pre-set temperature by 2°C per hour up to a maximum of 4°C 
after 2 hours and maintain this temperature until the set time has expired.  

 

If you use the sleep function, first set the time switch to the set hours as described in the functions  
Residual time or Starting time. Then press the [TIMER] switch until the required hours appear on the 
display. After the hour display, the display switches automatically to the previous set temperature 
display. To change the temperature, press the switch [TEMP+] or [TEMP-]. With each press on the 
switch, the temperature increases or decreases by 1°C. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Klimatronic Transform 10500

Страница 1: ...Instruction Manual ...

Страница 2: ...60L day 70L day NOISE 50dB A 51 dB A 52dB A 53dB A 54dB A AIR CIRCULATION m h 360 400 420 450 450 COOLING AGENT R410a R410a R410a R410a R410a REMOTE CONTROL INCLUSIVE INCLUSIVE INCLUSIVE INCLUSIVE INCLUSIVE TIME SWITCH 0 24 STD 0 24 STD 0 24 STD 0 24 STD 0 24 STD DIMENSIONS mm WXDXH 300x480x630 300x480x630 300x505x778 300x505x778 300x505x778 NET WEIGHT 24 kg 25 kg 28 kg 29 5 kg 30 5 kg All figures...

Страница 3: ...n damage the power cable 7 Since the TRANSFORM unit emits hot air please observe a sufficient minimum safety distance to each wall Fig 1 8 Despite the splash water protection you should not operate the TRANSFORM unit in moist areas such as e g swimming baths or similar areas 9 The colour of the TRANSFORM unit can change slightly due to direct solar radiation 10 The TRANSFORM unit is equipped with ...

Страница 4: ...SFORM unit on a horizontal surface to ensure no water leaks out 4 The TRANSFORM unit must not be operated in an area with explosive and caustic substances 5 Clean the air filter regularly A contaminated air filter reduces capacity 6 Please wait at least 5 minutes after switching off the TRANSFORM unit before switching it back on to ensure the compressor is not damaged 7 The TRANSFORM unit is desig...

Страница 5: ...om temperature by 1 C respectively up to a minimum temperature of 15 C 5 LED DISPLAY The display shows the required target temperature in operation By pressing the TEMP or TEMP switch the current ambient temperature is briefly displayed When pressing the TIMER switch the number of hours is briefly shown until activation or deactivation In the dehumification function dH or HP upside down is shown i...

Страница 6: ...which the TRANSFORM unit is to switch off b After the flashing of the number of hours on the LED has stopped you can select the required function cooling heating dehumification and the required temperature c When the set number of hours has expired the TRANSFORM unit switches on automatically If you press the POWER switch before the time has expired the Timer programming is deleted and the TRANSFO...

Страница 7: ... entry of warm air into the room Set the function to COOLING Set the target temperature using the temperature control The settable temperature range is between 17 C and 30 C target temperature The TRANSFORM unit must only be used in an ambient temperature of maximum 32 C Note After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for 3 ...

Страница 8: ... a room temperature of more than 23 C or less than 7 C The TRANSFORM unit can also be operated with heating function if the outside temperature is lower than 7 C However you must then ensure that the TRANSFORM unit is operated inside and the room temperature is at least 7 C HEATING IN INDOOR OPERATION The TRANSFORM unit is in the room to be heated Connect the air hose and the air outlet grid to th...

Страница 9: ...it you can also control the TRANSFORM unit from inside using the remote control Note After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for 3 minutes Cooling effect may require a further 10 minutes Further information is available under the part Troubleshooting DEHUMIDIFICATION Humidity is extracted from the air collected in the wat...

Страница 10: ...en switching on the TRANSFORM unit I sense a smell What should I do Production related cause or incorrect storage of unit at e g dusty areas Odour development can arise on first use and after a longer period of non use by storing in unsuitable areas e g dusty areas Run the unit for a day The smell will disappear after a while In the case of intensive odour development air the room Can I operate th...

Страница 11: ... cooling agent lines too high or too low Temporary error on measuring output temperature Please switch the TRANSFORM unit off and start it again after approx 30 minutes If the error occurs continuously the TRANSFORM unit requires specialist inspection E3 Incorrect signal This error message in the cooling function refers to too high ambient temperatures and in the heating function to too low ambien...

Страница 12: ...nection elements for the air hose TF Comfort S Control Kit 4250058312037 Sensor controlled adapter for a wall or window boring with air lamellas integrated operating panel and a LCD remote control for convenient and automatic control of the TRANSFORM in outdoor operation TF Air Transfer Kit 4250058312044 Extension of the TRANSFORM with a second air hose The system can then e g air condition the li...

Страница 13: ... NOTE CONCERNING PROTECTION OF ENVIRONMENT This product must not be disposed of via normal household waste after its service life but must be taken to a collection station for the recycling of electrical and electronic devices The symbol on the product the operating instructions or the packaging indicate such disposal procedures The materials are recycable in accordance with their respective symbo...

Отзывы: