Sunsystem SWP 2N 300 Скачать руководство пользователя страница 4

4

ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ

ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ

 

     

INSTALLATION and OPERATION MANUAL

                     

     INSTALLATION and OPERATION MANUAL

protective equipment

i

Use only original SUNSYSTEM 

parts.

1.1. Requirements to  SWP installation 

room

When choosing a room for tank installation 

observe the following requirements:
- to have a drainage channel. Some 

maintenance procedures require draining 

of all water from the tank.
- Thermal insulation of the room. This 

provides efficiency of the appliance and 

prevents the water from freezing.

1.2. Requirements for installation.

- The length of connecting pipes between 

the water tank and consumer must be as 

short as possible.

- Before connecting the water tank  to the 

installation,  check  all  screw  connections 

(plug and etc.). In very rare cases - during 

transportation,  loading  and  unloading 

operations -  the screw connections may 

be loosen.

-  Before  commissioning,  check  the 

installation for leaks

- Do not exceed the working pressure of 3 

bar for buffer tank and 6 bar for hygienic 

stainless steel coil.
- If there is a risk of freezing of water in 

the tank - drain the tank completely or let 

the water tank works continuously. 

       

           Dear Customers,

             We strongly hope that the appliance 

you have bought from us will contribute 

to creating comfort at you homes and 

decreasing the energy expenditure.

This manual contains important 

information for the safe and correct 

installation,  start-up  and  trouble-free 

operation and maintenance of the water 

heater.

The water heater can be used for 

producing of domestic hot water (DHW) 

only in the manner described in this 

manual.

The application and any other was the 

area of   operation is not recommended by 

the manufacturer and is not responsible 

for the occurrence of defects or failures. 

1. INSTRUCTIONS TO INSTALLER

The preparation, installation 

and commissioning must be 

performed by an authorized 

installer / service.

During  installation  and  operation,  the 

country specific requirements and 

regulations must be observed:

• local construction regulations on 

installation of water tank; weight of the 

boiler to comply with the stability of the 

floor of the room where it will be installed.

• regulations and norms concerning 

the fitting of theinstallation with safety 

devices.

• safety during installation - personal 

Содержание SWP 2N 300

Страница 1: ...serie SWP 150 200 300 400 500 L WATER HEATERS FOR HEAT PUMP SYSTEMS INSTALLATION and OPERATION MANUAL Version 0 3 3 SWP N with one coil SWP 2N with two coils SWP NL with one coil ...

Страница 2: ...2 ТЕХНИЧЕСКИ ПАСПОРТ ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ INSTALLATION and OPERATION MANUAL ...

Страница 3: ...TALLER 4 1 1 Requirements to water tank installation room 4 1 2 Requirements for installation 4 2 DESCRIPTION ON SWP 5 3 CONNECTING OF RELIEF VALVE TO WATER TANK 12 4 TECHNICAL PARAMETERS 14 4 1 SWP NL with one coil 14 4 2 SWP N with one coil 16 4 3 SWP 2N with two coils 18 5 TRANSPORT AND PACKAGING 20 6 WARRANTY 20 7 RECYCLING 23 ...

Страница 4: ...ing of water in the tank drain the tank completely or let the water tank works continuously Dear Customers We strongly hope that the appliance you have bought from us will contribute to creating comfort at you homes and decreasing the energy expenditure This manual contains important information for the safe and correct installation start up and trouble free operation and maintenance of the water ...

Страница 5: ...satedbyitssmallerdiameter heat exchanger coil with increased surface Easy installation Suitable for solar water heating space heating and heat pump systems with large number of consumers 2 1 High efficiency insulation and outer casing The quality of the insulation of a water heater is a key factor for its heat conservation capability and energy efficiency All water heaters SWP series have a high e...

Страница 6: ...s When connect the heating element to the electric network make sure that it is properly grounded Wiring diagrams Water tank L Connection Lenght L mm Current W Voltage V 150 1 1 2 210 3000 230 400 200 1 1 2 210 3000 230 400 300 1 1 2 320 4500 230 400 400 1 1 2 410 6000 230 400 500 1 1 2 590 7500 230 400 In the table of technical parameters is specified location for installation of electric heating...

Страница 7: ...ТЕХНИЧЕСКИ ПАСПОРТ ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 7 INSTALLATION and OPERATION MANUAL 2 4 Thermometer ...

Страница 8: ... connection size mm Anode length mm Anode Pcs 150 1 1 4 230 1 200 1 1 4 300 1 300 1 1 4 400 1 400 500 1 1 4 600 1 2 6 Inspection opening Large and convenient inspection opening located in the lower part of the tank gives access for maintenance and cleaning The opening is closed by an enameled flange cover which may have a sleeve for fitting electric heater if necessary Water tank Capacity L Flange...

Страница 9: ... 60730 2 9 CONFORMITY TO REGULATIONS This product complies with Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EC TECHNICAL CHARACTERISTICS Temperature range regulation 0 C 90 C limit 90 C 110 C Tolerance Regulation 5k limit 15 k 6 k depends on the type Temperature differential Regulation 6 2 k 4 1 k depends on the type Limit 25 8 k 15 8 k depends on the type Automa...

Страница 10: ...al circuit breaker or switch on contacts Switch on action 2B Place of installation normal Type of wire M20 x 1 5 WARNING All installation operations including manual adjustments must be fulfilled by a qualified specialist following all safety conditions INSTALLATION AND CONNECTION Safety instructions Before connecting the thermostat make sure that THE UNIT TO BE THERMALLY CONTROLLED water heater p...

Страница 11: ...ature rises TERMINAL C common contact THERMOSTAT TERMINAL 1 opens the circuit when the temperature rises TERMINAL 2 closes the circuit when the temperature rises TERMINAL C common contact sheme 7 TEMPERATURE ADJUSTMENT see Scheme 8 A Reset button only for TLSC B Knob for temperature adjustmentct sheme 8 2 8 Screws with rubber head Included at standard water tank package Screws with rubber heads ar...

Страница 12: ...ly 2 Check return valve 3 Tee 4 Safety relief pressure valve 5 Cold water inlet water tank 6 Stopcock drainage Stop Shut off valves should never be installed between a safety relief valve and the tank It is recommended once a year to check the operation of the safety valve 3 CONNECTING OF SAFETY RELIEF VALVE TO WATER TANK ...

Страница 13: ...ТЕХНИЧЕСКИ ПАСПОРТ ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 13 INSTALLATION and OPERATION MANUAL ...

Страница 14: ...14 ТЕХНИЧЕСКИ ПАСПОРТ ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ INSTALLATION and OPERATION MANUAL 4 TECHNICAL PARAMETERS to serie SWP 4 1 SWP NL with one coil ...

Страница 15: ...ure coils S1 bar 0 C 16 110 16 110 16 110 Test pressure coils S1 bar 25 25 25 Coils capacity S1 L 20 4 23 6 28 3 Coils Heat exchange surface S1 m2 3 3 3 9 4 6 Inlet Outlet Lower coi S1 S1i S1o mm Rp1 1476 228 1390 260 1626 250 Prolonged power acc to DIN 4708 10 C 80 C 45 C S1 kW m3 h 90 2 21 115 2 70 130 3 19 NL power coefficient at 60 C S1 NL 60 C 11 14 18 Pressure drop Δp S1 Δp mbar 230 379 569 ...

Страница 16: ...16 ТЕХНИЧЕСКИ ПАСПОРТ ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ INSTALLATION and OPERATION MANUAL 4 2 SWP N with one coil ...

Страница 17: ...0 C 16 110 16 110 16 110 16 110 16 110 Test pressure coils S1 bar 25 25 25 25 25 Coils capacity S1 L 8 6 11 7 14 8 17 2 20 Coils Heat exchange surface S1 m2 1 4 1 9 2 3 2 8 3 3 Inlet Outlet Lower coi S1 S1i S1o mm Rp1 872 182 1122 182 1155 215 1210 270 1350 270 Prolonged power acc to DIN 4708 10 C 80 C 45 C S1 kW m3 h 40 4 0 99 51 1 25 62 1 52 75 1 84 84 2 06 NL power coefficient at 60 C S1 NL 60 ...

Страница 18: ...18 ТЕХНИЧЕСКИ ПАСПОРТ ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ INSTALLATION and OPERATION MANUAL 4 3 SWP 2N with two coils ...

Страница 19: ... 25 25 Coils capacity S1 S2 L 6 5 16 1 10 18 9 11 8 26 Coils Heat exchange surface S1 S2 m2 1 2 2 7 1 5 3 2 1 8 4 36 Inlet Outlet Lower coi S1 S1i S1o mm Rp3 4 435 215 562 240 606 240 Inlet Outlet Upper coi S2 S2i S2o mm Rp3 4 1105 587 1195 665 1446 726 Prolonged power acc to DIN 4708 10 C 80 C 45 C S1 S2 kW m3 h 53 1 30 75 1 84 62 1 52 82 2 01 72 1 77 94 2 31 NL power coefficient at 60 C S1 S2 NL...

Страница 20: ...during warranty period of respective product im mediately after any defects have been de termined except for in case of noticeable defects at the moment of purchase in safety equipment must be used in accordance with Directive 2006 42 EC When transporting items weighing more than 30 kg the use of pallet jack fork truck or other hoisting devices is a must Capacity of Water tank L 150 200 300 400 50...

Страница 21: ...eports from the claims they have re ceived for the purpose of checking every aspect that might be useful for better consideration of warranty claims for this reason the customer shall not make any 5 Freeze flood natural disasters or third party actions as well as any interventions into normal functioning conditions of wa ter heaters and the control of NES Ltd The customer as well should monitor th...

Страница 22: ...to be claimed ex cluded is any liability for indirect damages such as loss of data at information appli cations loss of production thermal vari ations at the service etc which do not violate the applicable regulations of any country concerning product liability c Abovementioned warranty limi tations will be applied in any cases and when they do not violate the regulations in any country concerning...

Страница 23: ... electrical and electronic equip ment waste disposal thereof is required separately from the normal flow of solid household waste Obsolete equipment shall be collected separately from oth er recyclable waste containing materials with adverse effect on health and envi ronment Expired appliances must be collected sep arately from other recyclable waste con taining substances hazardous to health and ...

Страница 24: ...ISO 9001 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg ...

Отзывы: