For this purpose the claimant shall fill out 

a claim form; the latter shall be accompa

-

nied by the document proving the pur-

chase of the water heater (invoice) with 

the date of purchase in it.

b) After receiving the claim form, NES Ltd. 

considers it and makes decision whether 

the claim has grounds, and whether the 

defect is within the scope of the warranty 

set forth in this  certificate for limited war

-

ranty;  after  which  informs  the  customer 

as to its decision and the steps he shall do.

c) The return of a product cannot be done 

without  written  authorization  issued  by 

the Quality Department. The return pro-

cedure shall be according to RMA (Return 

Material Authorization).

d)  If  on  customer’s  request,  and  when 

there is reason for urgency, the customer 

demands  immediate replacement of the 

product he has claimed warranty for, be

-

fore making the decision as to the claim, 

said request shall be accompanied by a 

Purchase  requisition  from  the  Commer

-

cial Department. After decision for satis

-

faction of the claim has been made, the 

Purchase  requisition  mentioned  above 

will be annulled by issuing a receipt for 

returned goods; with this receipt the 

customer can purchase another product 

with the same price in case the claim has 

proved grounded.

e) NES Ltd. reserves the right to make in 

situ reports from the claims they have re-

ceived for the purpose of checking every 

aspect  that  might  be  useful  for  better 

consideration of warranty claims; for this 

reason the customer shall not make any 

5) Freeze, flood, natural disasters or third 

party actions as well as any interventions 

into normal functioning conditions of wa

-

ter heaters and the control of NES Ltd. 

The customer as well should monitor the 

anticorrosion system (magnesium anodе). 

He should periodically check the mag-

nesium anode and replace it depending 

on  the  geographic  location  at  intervals 

depending  on  the  type  of  water  (soft  of 

hard) of the region where the water heat-

er is being used.

b)  The  warranty  certificate  is  considered 

void for water heaters whose serial iden-

tification number has been modified, re

-

moved or blurred, or cannot be expressly 

attested.

c) Damages in the appearance of products 

shall not be considered as defects except 

for those ones which cause losses during 

operation  or  change  technical  character

-

istics  of  water  heaters  set  forth  in  bro

-

chures.

d) NES Ltd. preserves the right, in case of 

replacement, to deliver another model of 

water  heater  in  order  to  fulfill  approved 

warranty claims when the original model 

is not being manufactured.

6.3. Claiming warranty

Every customer who has purchased a wa-

ter  heater  from  NES  Ltd.,  and  who  has 

good reasons to lay a warranty claim, shall 

proceed as follows:

a) Immediately notify in writing:

    1) The installer, or the company that has 

sold the water heater to him, or

    2) The distributor firm, or

        3)  The  commercial  representative  of 

NES Ltd. in the region. 

Содержание SWP 2N 300

Страница 1: ...serie SWP 150 200 300 400 500 L WATER HEATERS FOR HEAT PUMP SYSTEMS INSTALLATION and OPERATION MANUAL Version 0 3 3 SWP N with one coil SWP 2N with two coils SWP NL with one coil ...

Страница 2: ...2 ТЕХНИЧЕСКИ ПАСПОРТ ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ INSTALLATION and OPERATION MANUAL ...

Страница 3: ...TALLER 4 1 1 Requirements to water tank installation room 4 1 2 Requirements for installation 4 2 DESCRIPTION ON SWP 5 3 CONNECTING OF RELIEF VALVE TO WATER TANK 12 4 TECHNICAL PARAMETERS 14 4 1 SWP NL with one coil 14 4 2 SWP N with one coil 16 4 3 SWP 2N with two coils 18 5 TRANSPORT AND PACKAGING 20 6 WARRANTY 20 7 RECYCLING 23 ...

Страница 4: ...ing of water in the tank drain the tank completely or let the water tank works continuously Dear Customers We strongly hope that the appliance you have bought from us will contribute to creating comfort at you homes and decreasing the energy expenditure This manual contains important information for the safe and correct installation start up and trouble free operation and maintenance of the water ...

Страница 5: ...satedbyitssmallerdiameter heat exchanger coil with increased surface Easy installation Suitable for solar water heating space heating and heat pump systems with large number of consumers 2 1 High efficiency insulation and outer casing The quality of the insulation of a water heater is a key factor for its heat conservation capability and energy efficiency All water heaters SWP series have a high e...

Страница 6: ...s When connect the heating element to the electric network make sure that it is properly grounded Wiring diagrams Water tank L Connection Lenght L mm Current W Voltage V 150 1 1 2 210 3000 230 400 200 1 1 2 210 3000 230 400 300 1 1 2 320 4500 230 400 400 1 1 2 410 6000 230 400 500 1 1 2 590 7500 230 400 In the table of technical parameters is specified location for installation of electric heating...

Страница 7: ...ТЕХНИЧЕСКИ ПАСПОРТ ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 7 INSTALLATION and OPERATION MANUAL 2 4 Thermometer ...

Страница 8: ... connection size mm Anode length mm Anode Pcs 150 1 1 4 230 1 200 1 1 4 300 1 300 1 1 4 400 1 400 500 1 1 4 600 1 2 6 Inspection opening Large and convenient inspection opening located in the lower part of the tank gives access for maintenance and cleaning The opening is closed by an enameled flange cover which may have a sleeve for fitting electric heater if necessary Water tank Capacity L Flange...

Страница 9: ... 60730 2 9 CONFORMITY TO REGULATIONS This product complies with Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EC TECHNICAL CHARACTERISTICS Temperature range regulation 0 C 90 C limit 90 C 110 C Tolerance Regulation 5k limit 15 k 6 k depends on the type Temperature differential Regulation 6 2 k 4 1 k depends on the type Limit 25 8 k 15 8 k depends on the type Automa...

Страница 10: ...al circuit breaker or switch on contacts Switch on action 2B Place of installation normal Type of wire M20 x 1 5 WARNING All installation operations including manual adjustments must be fulfilled by a qualified specialist following all safety conditions INSTALLATION AND CONNECTION Safety instructions Before connecting the thermostat make sure that THE UNIT TO BE THERMALLY CONTROLLED water heater p...

Страница 11: ...ature rises TERMINAL C common contact THERMOSTAT TERMINAL 1 opens the circuit when the temperature rises TERMINAL 2 closes the circuit when the temperature rises TERMINAL C common contact sheme 7 TEMPERATURE ADJUSTMENT see Scheme 8 A Reset button only for TLSC B Knob for temperature adjustmentct sheme 8 2 8 Screws with rubber head Included at standard water tank package Screws with rubber heads ar...

Страница 12: ...ly 2 Check return valve 3 Tee 4 Safety relief pressure valve 5 Cold water inlet water tank 6 Stopcock drainage Stop Shut off valves should never be installed between a safety relief valve and the tank It is recommended once a year to check the operation of the safety valve 3 CONNECTING OF SAFETY RELIEF VALVE TO WATER TANK ...

Страница 13: ...ТЕХНИЧЕСКИ ПАСПОРТ ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 13 INSTALLATION and OPERATION MANUAL ...

Страница 14: ...14 ТЕХНИЧЕСКИ ПАСПОРТ ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ INSTALLATION and OPERATION MANUAL 4 TECHNICAL PARAMETERS to serie SWP 4 1 SWP NL with one coil ...

Страница 15: ...ure coils S1 bar 0 C 16 110 16 110 16 110 Test pressure coils S1 bar 25 25 25 Coils capacity S1 L 20 4 23 6 28 3 Coils Heat exchange surface S1 m2 3 3 3 9 4 6 Inlet Outlet Lower coi S1 S1i S1o mm Rp1 1476 228 1390 260 1626 250 Prolonged power acc to DIN 4708 10 C 80 C 45 C S1 kW m3 h 90 2 21 115 2 70 130 3 19 NL power coefficient at 60 C S1 NL 60 C 11 14 18 Pressure drop Δp S1 Δp mbar 230 379 569 ...

Страница 16: ...16 ТЕХНИЧЕСКИ ПАСПОРТ ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ INSTALLATION and OPERATION MANUAL 4 2 SWP N with one coil ...

Страница 17: ...0 C 16 110 16 110 16 110 16 110 16 110 Test pressure coils S1 bar 25 25 25 25 25 Coils capacity S1 L 8 6 11 7 14 8 17 2 20 Coils Heat exchange surface S1 m2 1 4 1 9 2 3 2 8 3 3 Inlet Outlet Lower coi S1 S1i S1o mm Rp1 872 182 1122 182 1155 215 1210 270 1350 270 Prolonged power acc to DIN 4708 10 C 80 C 45 C S1 kW m3 h 40 4 0 99 51 1 25 62 1 52 75 1 84 84 2 06 NL power coefficient at 60 C S1 NL 60 ...

Страница 18: ...18 ТЕХНИЧЕСКИ ПАСПОРТ ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ INSTALLATION and OPERATION MANUAL 4 3 SWP 2N with two coils ...

Страница 19: ... 25 25 Coils capacity S1 S2 L 6 5 16 1 10 18 9 11 8 26 Coils Heat exchange surface S1 S2 m2 1 2 2 7 1 5 3 2 1 8 4 36 Inlet Outlet Lower coi S1 S1i S1o mm Rp3 4 435 215 562 240 606 240 Inlet Outlet Upper coi S2 S2i S2o mm Rp3 4 1105 587 1195 665 1446 726 Prolonged power acc to DIN 4708 10 C 80 C 45 C S1 S2 kW m3 h 53 1 30 75 1 84 62 1 52 82 2 01 72 1 77 94 2 31 NL power coefficient at 60 C S1 S2 NL...

Страница 20: ...during warranty period of respective product im mediately after any defects have been de termined except for in case of noticeable defects at the moment of purchase in safety equipment must be used in accordance with Directive 2006 42 EC When transporting items weighing more than 30 kg the use of pallet jack fork truck or other hoisting devices is a must Capacity of Water tank L 150 200 300 400 50...

Страница 21: ...eports from the claims they have re ceived for the purpose of checking every aspect that might be useful for better consideration of warranty claims for this reason the customer shall not make any 5 Freeze flood natural disasters or third party actions as well as any interventions into normal functioning conditions of wa ter heaters and the control of NES Ltd The customer as well should monitor th...

Страница 22: ...to be claimed ex cluded is any liability for indirect damages such as loss of data at information appli cations loss of production thermal vari ations at the service etc which do not violate the applicable regulations of any country concerning product liability c Abovementioned warranty limi tations will be applied in any cases and when they do not violate the regulations in any country concerning...

Страница 23: ... electrical and electronic equip ment waste disposal thereof is required separately from the normal flow of solid household waste Obsolete equipment shall be collected separately from oth er recyclable waste containing materials with adverse effect on health and envi ronment Expired appliances must be collected sep arately from other recyclable waste con taining substances hazardous to health and ...

Страница 24: ...ISO 9001 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg ...