7
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUALINSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
2.4. Electric heating element /option/
All buffer tanks are equipped with
Outlet connection 1 ½“ for electric heating
element:
3000W
/230
V
; 4500
W
/230
V
;
6000W
/230
V
; 7500
W
/400
V.
The connection of the electric
heating element to the electric
power supply must be done by a
qualified electricians.
When connect the heating
element to the electric network,
make sure that it is properly
grounded.
In the table of technical parameters
is specified location for installation of
electric heating element.
Buffer tank
Capacity, L
Connection
Length
L, mm
Current,
W
Voltage,
V
150 ÷ 5000
1
1/2”
210
3000
230
300 ÷ 5000
1
1/2”
320
4500
230
400 ÷ 5000
1
1/2”
410
6000
230
500 ÷ 5000
1
1/2”
590
7500
230/400
Содержание P 1500
Страница 2: ...2 INSTALLATION and OPERATION MANUALINSTALLATION and OPERATION MANUAL ...
Страница 8: ...8 INSTALLATION and OPERATION MANUALINSTALLATION and OPERATION MANUAL CONNECTIONS SCHEMES ...
Страница 9: ...9 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ...
Страница 13: ...13 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ...
Страница 36: ...36 INSTALLATION and OPERATION MANUALINSTALLATION and OPERATION MANUAL 8 SHEMES t 65 C ...
Страница 37: ...37 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ...
Страница 38: ...38 INSTALLATION and OPERATION MANUALINSTALLATION and OPERATION MANUAL ...
Страница 43: ...INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ...
Страница 44: ...ISO 9001 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg ...