7
EN
TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL
Chromium content
mg / kg
2)
≤ 10
≤ 10
≤ 10
Arsenic content
mg / kg
2)
≤ 1,0
≤ 1,0
≤ 1,0
Cadmium content
mg / kg
2)
≤ 0,5
≤ 0,5
≤ 0,5
Mercury content
mg / kg
2)
≤ 0,1
≤ 0,1
≤ 0,1
Lead content
mg / kg
2)
≤ 10
≤ 10
≤ 10
Nickel content
mg / kg
2)
≤ 10
≤ 10
≤ 10
Zinc content
mg / kg
2)
≤ 100
≤ 100
≤ 100
1)
not more than 1% of the pellets may be longer than 40 mm, max. length 45 mm;
2)
dry weight;
3)
particles <3.15 mm, particulate matter, before handing over the goods;
4)
measurements with Ligno-Tester limit value ≥ 97,7% by weight.
4. TRANSPORTATION OF THE BOILER
We recommend to transport the heating boiler to the
installation site in its packaging placed on the pallet.
During transport and installation, depending on the
weight, suitable safety devices should be used in
accordance with Directive 2006/42/EC.
When transporting items weighing more than 30 kg,
the use of pallet jack, fork truck or other hoisting
devices is a must.
Product must be in original packaging following
the instructions on the label - to be protected from
adverse weather conditions (snow, rain and dust)
from the shocks, and other activities likely to cause
damage. In case of malfunction of the fan or the
motor drive (noise, friction) or failure of high-tech
elements such as broken controller-screen, contact
your nearest authorized service center for repairs
and maintenance.
The boiler is securely fastened with fasteners to a
wooden pallet.
Important: When installing the boiler, the
wooden pallet onto which the boiler is
placed must be removed by unscrewing
the bolted connections using flat ring
wrench S13.
Diagram 5. Indications dimensions /see
page 58/
Table 4. Overall dimensions of Set Pellet boiler PelleBurn, Pellet burner Pell and Fuel Hopper FH 500-V2
PelleBurn
15
25
40
A1, mm
Pellet boiler, burner and pallet
710
710
810
A2, mm
Auger, box
120
120
120
A3, mm
Fuel Hopper, box
840
840
840
B1, mm
Pellet boiler, burner and pallet
1100
1100
1320
B2, mm
Auger, box
260
260
260
B3, mm
Fuel Hopper, box
810
810
810
C, mm
Pellet boiler, burner and pallet
125
125
125
D1, mm
Pellet boiler, burner and pallet
1430
1630
1775
D2, mm
Auger, box
1700
1700
1700
D3, mm
Fuel Hopper, box
1220
1220
1220
Weight, kg
Pellet boiler, burner and pallet
232
275
387
Auger, box
10
10
10
Fuel Hopper, box
73
73
73
5. DELIVERY OF THE BOILER
•
Inspect the integrity of the packaging upon
delivery.
• Check whether all components have been
delivered to you.
Boiler consignment package includes:
1) Pellet boiler PelleBurn with pellet burner Pell
2) Auger
3) Fuel hopper FH 500-V2 (option)
4) Safety valve 3 bar.
5) Fire irons
6) Technical passport. Installation and operation
manual
7) Service booklet and Warranty card
If any of the above items are missing, contact your
supplier.
Содержание Burnit PelleBurn 15
Страница 58: ...58 Diagrams Schemes Schémas 1 3 2 4 5 ...
Страница 59: ...59 Diagrams Schemes Schémas 5 1 6 45o ...
Страница 61: ...61 Diagrams Schemes Schémas 9 10 CHPUMP RT room thermostat TTOP TBOTTOM CHPUMP ...
Страница 64: ...64 Diagrams Schemes Schémas 11 T TOP T BOTTOM CHPUMP DHW sensor CHPUMP DHWPUMP TTOP TBOTTOM 12 ...
Страница 65: ...65 Diagrams Schemes Schémas 23 23 1 U H D V W1 Z O Т F P M W2 D K W F P L J B L A N B ...
Страница 66: ...66 Diagrams Schemes Schémas 24 25 26 27 ...
Страница 67: ......