3
EN
TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL
1. EXPLANATION OF SYMBOLS AND SAFETY
INSTRUCTIONS
1.1. Explanation of symbols
CAUTION!
- Important recommendation or
warning concerning safety conditions during
installation and operation of boiler.
DANGER!
- fault or improper use may cause
injury or be hazardous to life of humans or
animals.
FIRE HAZARD!
- fault or improper installation
and operation may cause fire.
INFORMATION
– Important information on
the proper operation of the product.
1.2. Requirements to boiler installation room
This manual contains important information for the
safe and correct installation, start-up and trouble-
free operation and maintenance of the boiler.
The Pellet boiler can be used for heating rooms only
in the manner described in this manual.
The application and any other was the area of
operation is not recommended by the manufacturer
and is not responsible for the occurrence of defects
or failures.
Note the boiler type data on the factory rating label
and the technical data provided in chapter 13 in
order to ensure proper operation of the product.
1.2.1. Instructions to boiler installer
During installation and operation, the country-
specific requirements and regulations must be
observed:
• Local construction regulations on installation,
air supply and exhaust gas extraction as well as
chimney connection.
• Regulations and norms concerning the fitting of the
heating installation with safety devices.
• Required installation of a smoke detector in the
boiler room.
i
Use only original BURNiT parts
WARNING! Installation and setup of the
boiler should be done by an authorized
specialist / service shop and must follow
the safety instructions and rules of
operation.
It is mandatory to assure a backup power
generator of corresponding rated power!
(see table 1)
DANGER of intoxication, suffocation.
Inadequate inflow of fresh air to the
boiler room may result in dangerous leak
of exhaust gases during boiler operation.
- Make sure the air inlets and exhaust gas
outlets are not clogged or closed.
- If faults are not remedied immediately, the
boiler must not be operated.
- The user must be provided with written
instructions on the fault and the hazard it
entails.
!
DANGER of fire when burning flammable
materials or liquids.
-
Flammable materials/liquids must not be
left in close proximity of the burner and
heating boiler.
-
Instruct system user of the allowed
minimum clearances from surrounding
objects.
Customer must undergo boiler operation/
maintenance training by authorized
installer/service shop.
Table 1.
Electricity consumption of the boiler
Maximum electrical input
780 W
Electrical input at nominal heat output
80 W
Electrical input at minimum heat output
60 W
1.2.2. Instructions to installation user
$
DANGER of intoxication or explosion
Toxic gases may be discharged when
burning waste, plastics, liquids.
- Use only the fuels indicated in this manual.
- In case of danger of explosion, ignition or
discharge of exhaust gases in the room,
stop the pellet burner from operation.
CAUTION! Danger of injury / damage of
system due to incompetent operation.
- The boiler must be serviced only by persons
familiar with the operation manual.
- As user, you are only allowed to start the
boiler up, adjust the temperature of the
boiler, shut the boiler down and clean it.
- Unattended children must not be allowed
access to premises with running boiler
inside.
It is mandatory to assure a backup power
generator of corresponding rated power!
(see table 1)
Содержание Burnit PelleBurn 15
Страница 58: ...58 Diagrams Schemes Schémas 1 3 2 4 5 ...
Страница 59: ...59 Diagrams Schemes Schémas 5 1 6 45o ...
Страница 61: ...61 Diagrams Schemes Schémas 9 10 CHPUMP RT room thermostat TTOP TBOTTOM CHPUMP ...
Страница 64: ...64 Diagrams Schemes Schémas 11 T TOP T BOTTOM CHPUMP DHW sensor CHPUMP DHWPUMP TTOP TBOTTOM 12 ...
Страница 65: ...65 Diagrams Schemes Schémas 23 23 1 U H D V W1 Z O Т F P M W2 D K W F P L J B L A N B ...
Страница 66: ...66 Diagrams Schemes Schémas 24 25 26 27 ...
Страница 67: ......