30
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
i
Important: You use a burner
whose carbon footprint values
are approximately (СО = 100
ppm), which is 2.5 times lower
than the maximum allowed
limits for harmful emissions in
the EU Member States. Thus
you can reduce the amount of
harmful emission and contribute
to environment protection.
Important: For each of the
output modes the optimal fan
setting is tweaked by using gas
analyzer to control the oxygen
amount registered by the device
(within the range 8% ÷ 10%, and
for the lower modes up to 13%).
The specific setting depends
also on the internal resistance of
the boiler combustion chamber
on which the burner has been
installed as well as on the
chimney draught. Therefore it is
not possible to provide here the
exact value for the fan output
and it must be entered by a
competent installer or service
technician using gas analyzer
11. WARRANTY TERMS
The warranty terms are described in the
Service booklet included in the supply.
Содержание BURNiT Pell BIO Series