22
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
confirmation of command via the
"F"
button you may navigate to the next
screen.
From this menu
you can set up and
adjust
DHW pump
activity
periods.
Use the arrow keys to set time
(HH:MM)
.
Use
“Enter”
button to checkmark desired
time period option.
If no option is check-marked,
the controller will maintain
DHW
temperature
as a priority. Only when
its preset value is reached, the
CH
circulation pump
will start.
9.2.3. Burner shut-down "Standby"
Pressing the “
F
”
button will take you
to the main menu
and by using the
navigation arrows
you can select the “
Standby
” menu and
confirm the selection by pressing “
F
”.
The burner goes into extinguishing mode.
9.3. Installer's menu (setting the
combustion parameters in the burner
controller)
CAUTION! We recommend that
this menu be used only by an
authorized
installer/service
shop in order to ensure efficient
and safe operation of the
equipment
To access the
s e t t i n g s
a d j u s t m e n t
m o d e ,
simultaneously
press the
“Enter”
and „
F
” buttons and
hold them pressed for
4
/
four
/ seconds.
This will display the controller hardware
and software version on the screen. Press
again button
“Enter”
and this will open
the initial page for the burner settings.
For access to service settings menu you
need a service menu code.
The service menu
comprises only
and uniquely
parameters with
direct impact on
boiler combustion
process, as well as
on
heating
installation management (depending on
the peripherals management capacity of
the boiler digital controller unit).
Fuel switching and / or change
the configuration of the heating
installation must be performed
by an authorized installer /
service. Some of these reasons
may affect the safe operation of
the facility.
9.3.1. Menu for automatic dose pellets
for maximum power
Calculation of feeding:
Power
- Enter the
maximum power of the
model of boiler.
Important: Please enter the
exact power. Setting of higher
or lower power than is written
on production label of the boiler
can cause boiler damage or
physical injury.
Fuel C
- Set the calorific value of used
fuel. The calorific value is marked on fuel