24
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
running time of the main fan
(FAN)
and
of the cleaning motor
(Cleaner)
.
Select the desired option using the
navigation arrows. Use the „
Enter
”
button to open the next parameter. Use
the
button to open the next page of
the menu.
In this submenu
you can activate or
deactivate
the
automatic cleaning
of the burner in
Ignition
(Start)
mode or extinguished
(Stop)
mode. The checkmark in the box
indicates that the automatic cleaning
system is active.
9.3.3. Ignition setup
In this submenu
you can set the
number of attempts
(
Retries
) to ignite
the burner and the
time of the initial feed portion of pellets
(
Feed
). Select the desired option using
the navigation arrows. Use the „
Enter
”
button to open the next parameter. Use
the
button to open the next page of
the menu.
9.3.4. Cycle setup
Use this submenu
to adjust the
running time of the
heater (
Heater
) and
the running time
and output of the main fan during the
ignition of the initial portion of pellets.
Principle of operation:
After feeding the initial portion of pellets,
the heater operates for
2
minutes , and
the main fan is turned on at
20%
of its
capacity and operates for
3
minutes (the
heater continues to work). If upon the
expiration of that period the photosensor
detects the presence of stable flame, the
burner enters into operating mode. If no
stable flame is present, the burner feeds
in pellets again and repeats the process.
NOTE! Fan B/E 20/1 is a set up
for the main fan at 20% and set
up for the fan for fume gases 1%
(if there is installed). Fan for the
fume gases must be connected
to termonal FSG (see shceme 6).
Select the desired option using the
navigation arrows. Use the „
Enter
”
button to open the next parameter. Use
the
button to open the next page of
the menu.
9.3.5. Burn Level
The burner has
three main levels of
burning
(three
main output modes
of operation). Use
this menu to set the temperature
differences at which the burner will shift
from higher output mode to lower (step
modulation).
Example:
We have set maximum
temperature of
85°С
. Upon reaching
73°С
, the burner will shift down to lower
mode of operation (
two flames
). Upon
reaching
82°С
, the burner enters into still
lower mode of operation (
one flame
).
Upon reaching
85°С
, the burner enters
into suspend mode (
Suspend
).
Select the desired option using the
navigation arrows. Use the „
Enter
”
button to open the next parameter. Use