GEN/AUX
Connection for a generator
GRID
This works like a conventional grid-tied inverter. It is both an in and out
connection for non-essential load and supply
LOAD
Connection of essential loads such as lighting, security systems, and
internet
Please follow below steps to make the AC input/output connection:
1. Before making AC input/output connections, be sure to open DC protector or disconnector first.
2. Remove insulation sleeve 10mm length, unscrew the bolts, insert the AC input wires according to
polarities indicated on the terminal block and tighten the terminal screws.
3. Ensure that the connection was made properly.
Check that AC power source is isolated before attempting to wire it to the inverter Insert AC output wires
according to polarities indicated on the terminal block and tighten terminal. Be sure to connect
corresponding N wires and PE wires to related terminals and ensure the wires are securely connected.
Recommended AC Surge Protector