Website: www.sunsynk.com E-mail: [email protected]
35
SS4074
CAN
To be used with V2 Logger
http://solarmd.co.za/inverter-
compatibility-solarmd/sunsynk-
and-solar-md/
SS202
CAN
Freedomwon
Freedom Lite
Commercial
52V and HV
Models
CAN
www.freedomwon.co.za/storage/2
019/09/freedom-lite-commercial-
installation-manual-rev-2-
september-2019.pdf
REVOV
1
st
and 2
nd
life
RS485
PINS 1&2 must be Swopped at
Battery side.
SHOTO
No
Voltage Base Charge settings
must be used.
HUBBLE
No
Voltage Base Charge settings
must be used.
CCGX
48Vxxxx
CAN
0
Need confirm CAN_H CAN_L
SACRED
SUN
48Vxxxx
RS485
1
Cut Line 3, 6, 8
SOLAX
48Vxxxx
CAN
0
KOK
48Vxxxx
RS485
2
UZ ENERGY
UZ-EB51.2-
100-A11
CAN
0
Topakpower
48Vxxxx
RS485
4
Hai Ying
HY48050
CAN
0
Re-Power
LS4850
CAN
0
IMPORTANT
When not using communications between battery and inverter, never overcharge your battery bank
concerning current and voltage. Many lithium batteries are limited to 100A, some are lower and
some are higher. Ensure that voltage and current specifications provided by the battery
manufacturer are followed.
If you're using lead-acid batteries then a good rule of thumb is C X 25, which means that the
maximum charge of discharge you can apply to the battery is a quarter of the AH rating of the
overall battery array. For example, for a 200AH battery array that could be composed of 4×200
power batteries in series has a maximum charge and discharge of only 50A.
Also, ensure the cable is thick enough to support the current and proper fuse following the
recommendations of the battery manufacturers.