Appendix B
Inverters sold in Australia will be set to the Default Australian standards
Appendix C
The Sunsynk inverter is compatible with the SolarMan app, via a Wifi or GSM data logger (See solarman
instruction manual).
Copy enclosed
Appendix D
If an external residual current device (RCD) is used, a device of type (A/AC, etc.) should be employed,
with a tripping current of 30mA or higher.
Use of RCDs
Residual current devices (RCDs): An RCD dedicated for an IES may be used to meet the mechanical
cable protection requirements and isolation requirements of AS/ NZS3000 for the cable from the
switchboard to the IES. If an RCD is used, the RCD shall
1. disconnect all live conductors (including the actives and neutral); and
2.
be of the type specified in the inverter manufacturer’s instructions or as labelled on the inverter.
We recommend the use of an RCD on all circuits and sub circuits connected to the Sunsynk inverter.
Residual current breaker with overcurrent protection (RCBO)
Earth-leakage protection class
Type A
Earth-leakage sensitivity
30mA
Curve code
C
Network type
AC
Poles description
2P
Earth-leakage protection time delay
Instantaneous
Appendix E