background image

32

Sunstone Welders 

User Manual

:  

CDDP-A

Settings Screen Pop Ups

1. Restore all default settings pop up.

a. Click “Yes” to restore defaults and click “No” to not restore defaults and 
go back to the system settings screen.

1. Clear all memory pop up.

a. Click “Yes” to clear all memory and click “No” to not clear memory and 
go back to the system settings screen.

 

1. Missing update pop up.

a. The system cannot find the update file “*.apk” on the usb drive.  Please 
ensure the file is on the usb drive and is not in a folder.
b. Sometimes a little time is required between inserting the USB drive and 
pressing the update button. Press “Dismiss” and try again.

 

1.  After pressing “Update over Wi-Fi” and welder is not connected to a 
network this pop up will appear.
2. It will list the available networks and allow you to choose from one of 
them.
3. If you do not see your network/your network is hidden, you can choose 
“Other Network” to manually type in your network SSID.
4. You can cancel if you wish to not update over Wi-Fi.

 

1. This dialog box appears when user chooses to enter their own network 
SSID, by pressing “Other” network.

 

Содержание CD200DP-A

Страница 1: ...Sunstone Welders User Manual CDDP A Sunstone Welders Advanced Capacitive Discharge Dual Pulse Welder User Manual for Models CD200DP A CD400DP A CD600DP A...

Страница 2: ...ive Weld Terminal P 11 Fuse P 11 Power Inlet P 11 Welder to Weld Head Setup P 11 Configuration 1 P 11 Configuration 2 P 11 Configuration 3 P 12 Welder to Hand Held Attachment Setup P 12 Roll Spot Setu...

Страница 3: ...eeding with the welding process At Sunstone Engineering we are committed to producing quality products and ensuring complete owner satisfaction If you require assistance after reading this manual do n...

Страница 4: ...cuit Adjustable pulse width Energy storage adjustable from less than 1 to 100 capacity Up to 650 welds min using CD200DP A 110 or 220VAC input Simple user friendly interface Quick energy release for w...

Страница 5: ...weld nugget Formation of the weld nugget occurs during the first few milliseconds of the welding process Sunstone s proprietary technology allows the energy to be discharged with very high peak curren...

Страница 6: ...a lower contact resistance Tips WELD PRESSURE Several other factors play a part in the contact resistance The larger the contact resistance the hotter the resultant weld On the micro scale contact res...

Страница 7: ...ation can be found on p 14 of this manual FIGURE 4 Touch Screen Interface Chapter 3 Setup Pre Setup Information VOLTAGE AND POWER REQUIREMENTS Sunstone Advanced Capacitive Discharge Dual Pulse CDDP A...

Страница 8: ...t will turn off Warning DO NOT turn the welder off during boot up Allow enough time for unit to completely boot up before turning unit off WELD ON OFF A latching push button that enables welding when...

Страница 9: ...n action 5 Weld Ready Pull this pin up to 12V by connecting it with Pin 2 12V Signal will go low 0V when weld is ready 6 Alarm Pull this pin up to 12V by connecting it with Pin 2 12V Signal will go lo...

Страница 10: ...to actuate Pin 4 GND Shield FIGURE 11 WH Control Connector SD 40LS PRIMARY TRIGGER MATES TO SD 50LP Pin 1 Variable Foot Pedal Connect this to Pin5 12VDC with a 10Kohm potentiometer Pin 2 Primary Trigg...

Страница 11: ...Connect the female end of the power cord into the back of the welder and the male end into an AC power outlet 3 Attach weld head or hand attachment cables to negative and positive terminals 4 Ensure...

Страница 12: ...er outlet 3 Attach weld head to negative and positive terminals 4 Ensure either E STOP bypass plug in plugged in or an E STOP switch is plugged into the 6 DIN E STOP connector labeled E STOP on back p...

Страница 13: ...r cable to the back of the welder 3 Plug the welder power cable into an AC power outlet 4 Turn the welder on and set the desired energy settings 5 Roll Spot mode can be turned on or off in the Control...

Страница 14: ...like when using the dual pulse setting as outlined above SETTING Pulse 1 AND 2 The Pulse 1 energy setting should be chosen such that the parts adhere weakly To determine Pulse 1 turn off Pulse 2 and...

Страница 15: ...ypical time for this is between 1 and 50 milliseconds Pulse 1 The duration of this delay is dependent on the energy programmed on welder for Pulse 1 Cool The duration of delay is dependent on the time...

Страница 16: ...User can select between 1 and 100 milliseconds This time will be ignored if either pulse is disabled Pulse 2 The duration of this delay is dependent on the energy programmed on welder for pulse 2 Hold...

Страница 17: ...will depend on the time needed to charge to the desired energy but will typically be between 50 and 5000 milliseconds minus the length of the hold time Automation The CDDP A units will come with a bas...

Страница 18: ...ance Internal verifications can be performed but can only be accessed through a technical support screen This can be performed anytime the welder seems to be creating weak welds User will want to perf...

Страница 19: ...r a All or part of this energy can be divided into Pulse 1 and Pulse 2 b In order for Part Check to work as intended a Total Stored Energy must be set to a minimum of 25WS for CD600DPA 20WS for CD400D...

Страница 20: ...tor fails a User can choose to compare any or all of the different types 4 User can choose whether to use the comparator on the first or second pulse 5 Each pulse has an upper limit 6 Each pulse has a...

Страница 21: ...ill appear instead of the single previous weld result 2 A histogram of previous weld results a It shows the upper and lower limit b Shows the median line between upper and lower limit c Green dots are...

Страница 22: ...cess c Auto With Trigger i Squeeze Time is not used because weld head will trigger weld Hold Time is used ii Primary trigger starts the weld process 4 The time the weld head is given to squeeze weld p...

Страница 23: ...f chosen both inputs are used and user can choose which saved welds are associated with the Remote Schedule Select slots in the Remote Schedule Select sub tab within the PLC tab d User can select betw...

Страница 24: ...bit i Input PIN 1 high 0 and input PIN 2 high 0 will select schedule 0 ii Input PIN 1 high 0 and input PIN 2 low 1 will select schedule 1 iii Input PIN 1 low 1 and input PIN 2 high 0 will select sched...

Страница 25: ...clear your weld results history 5 This will save all your welder settings including saved settings to a USB stick 6 This will take your saved welder settings from a USB stick load all current setting...

Страница 26: ...latest files a Unit needs to be connected to Wi Fi b A dialog will display if you are up to date 4 Button can be pressed to delete all media videos and manuals 1 Download latest videos and manuals po...

Страница 27: ...ed to go back or forward in time b Video can be paused or resumed c Video can be adjusted to any time by using the scroll bar 3 If the user would like to load and use the settings shown in the video t...

Страница 28: ...mber and press done The PDF viewer will navigate to that page Save Load Screen 1 In this screen the user has the ability to save and or load weld settings a The waveform for current settings or select...

Страница 29: ...ave Load screen 1 If user chooses to save a weld with the same name then this pop up will appear to notify the user that a 1 was attached to the title before being saved a User can only acknowledge th...

Страница 30: ...ettings c The current lock state is listed on this screen 2 This button toggles between the screen being locked and unlocked 1 Lock Welder Pop up a User can choose a full or limited lock b User can ch...

Страница 31: ...coming soon 4 User can adjust the volume of the speaker for audible sounds 5 User can adjust screen brightness on screen for different lighting environments 1 System Settings tab a In this screen use...

Страница 32: ...re the file is on the usb drive and is not in a folder b Sometimes a little time is required between inserting the USB drive and pressing the update button Press Dismiss and try again 1 After pressing...

Страница 33: ...a status of the download a Once the progress is at 100 this dialog box disappears and starts updating the software 1 This dialog pops up after user has chosen to update over USB a Once the progress i...

Страница 34: ...p will automatically disappear if the electrode becomes unstuck If the emergency stop is active this pop up will appear Reasons for the pop up can include internal communication error voltage error on...

Страница 35: ...is having hardware issues this pop up will appear If this pop up persists contact support While saving a weld this pop up will appear This lets the users know that time is needed to store the saved we...

Страница 36: ...f the weld head doesn t send a response back to welder to weld this pop up will appear After overheating and once the welder is cooled this pop up will appear This error will appear if the capacitors...

Страница 37: ...r this pop up will appear If a trigger was received from a different source than specified this pop up will appear If you are trying to export data to a USB drive and the drive is out of memory this p...

Страница 38: ...ly seen when using hand held attachments CD200DP A CD400DP A CD600DP A 1 AWG4 Ft 6583 7625 8080 4 AWG 6Ft 5448 6310 6690 8 AWG 6 Ft 3038 3520 3730 Minimum Load 1mOhm using a smaller load may damage th...

Страница 39: ...15VAC AC Current typ 8 5A 115VAC 5A 230VAC 8 5A 115VAC 5A 230VAC 8 5A 115VAC 5A 230VAC TABLE 5 Weld Pulse Characteristics Model Min and Max Output Pulse Width Rise Time to max voltage Min Pulse Height...

Страница 40: ...40 Sunstone Welders User Manual CDDP A SUNSTONE ENGINEERING R D CORPORATION 1693 American Way Suite 5 Payson UT 84651 1 877 786 9353 toll free 1 801 658 0015 international SunstoneWelders com...