Remote Schedule Select
1. Remote Schedule Select sub tab
2. User can enable/disable remote schedule select
a. The two input PLC PINS will be automatically assigned to
Remote Schedule Select if it is enabled, and they will return
to an unassigned stated when it is disabled.
3. User can select saved welds by clicking on the drop down
menu and selecting the saved weld name.
a. User can choose 4 different schedules that are selectable
through the two PLC input PINS on the 8DIN connector
on the back panel. These will be passed in using a bit
mapping. (Keep in mind that the inputs are reverse logic,
so a low will actually be a ‘1’ and a high will be a ‘0’. Input
PIN 1 is the most significant bit.)
i. Input PIN 1 high(0) and input PIN 2 high(0) will select schedule 0.
ii. Input PIN 1 high(0) and input PIN 2 low(1) will select schedule 1.
iii. Input PIN 1 low(1) and input PIN 2 high(0) will select schedule 2.
iv. Input PIN 1 low(1) and input PIN 2 low(1) will select schedule 3.
Alarms
1. Alarms tab within communication screen
2. Displays current Temperature, Comparator Failures in a Row,
and Weld Count
3. Alarm Settings
a. User can enable or disable warnings and/or alarms
by touching the dot. Note that if a warning and it’s
corresponding alarm are both enabled and active, then only
the alarm will actually display. But the warning will be active
up until the alarm is also active.
b. Warning and Alarm limits can be input for Temperature,
Comparator Failures in a Row, and Weld Counter Preset
Limit.
c. Electrode Stuck, Part Check Failed, Trigger In No Weld
State, and Wrong Trigger Detected will be turned on by
default.