The fixed blade body
⒃
simultaneously moves to the
left with the moving fixed body
③
and stops after
contacting the stopper for fixed blade body
⒔
. At this
point, the fixed blade will slide under the needle plate
and begin to move.
(6) Position of fixed blade body
A. Unfasten the screw
⒕
.
B. Set a clearance of 1mm between the left end tip of the
thread trimming base
⒖
and the left end tip of the
stopper for fixed blade body
⒔
.
C. Adjust the screw
⒕
afterwards.
Before adjustments, always turn off the motor switch and check to make sure that the motor is in stop
mode.
Warning
Do not force the fixed blade body
⒃
to the left for the clamp spring
pressure can touch the looper.
Warning
[ Figure 88 ]
⒃
⒔
⒕
⒖
③
1mm