43
E. Press “P4” and the chosen folder is examined for pattern files.
■
Press “P4” once, and the initial position of the pattern file within
the chosen folder is displayed.
ⓐ
Folder name
ⓑ
Pattern file name
■
Press “P4” again, and the next pattern file position is displayed.
■
Choose the desired pattern file and then press
to store
the location of the pattern file. The screen displays “Mode”.
READY
F. Press “P6”, and the screen displays “r-33”.
G. Use
and change “r-33” to “r-40”.
H. If
is pressed, the screen displays “doUn”, and then the
standby mode.
I. When
is pressed, it is checked whether CF is
existing. If no error is found, pattern data are transferred. When the
transfer is completed, the screen displays “End”.
■
When an error occurs displaying “CF.Er” on screen, examine the
CF card and press “P1”. The screen displays “doUn”, and the
patterns are automatically transferred.
◀
CAUTION
▶
Whenever one package transfer is completed, a beep sound is issued.
J. Press
, and the screen displays “CF--”.
■
In order to continue to download other patterns, repeat the
procedures above from E to I.
■
If the pattern download is desired from other folder, repeat the
procedures above from D to I.
K. Press
, and the screen displays the sewing mode.
◀
CAUTION
▶
The screen displays the pattern number stored in the memory.
L. Use
or
to select the downloaded pattern
number.
M. Press
, and conduct sewing by stepping on the pedal.
READY
+/FORWARD
–/BACK
SELECT
RESET
CF Card Download
READY
+/FORWARD
0 5 . 1 0
r - 3 3
r - 4 0
d o U n
C F . O K
E n d
C F - -
4 0
ⓐ
ⓑ
How to create pattern files (in case of SSP-WE/2.0)
1) Up to 96 pattern files can be stored within a folder.
2) Create a folder name by entering a two-digit number followed by extension “.btk” such as
00.btk, 01.btk, 02.btk,
…
…
, 95.btk .
2)
If the naming rule is not followed, the folder name cannot be displayed on the screen.
3) If there are no patterns within a folder, “FL.Er” is displayed on the screen.
Caution