33
(7) Testing Pedal Input
1. Run the Machine TEST and then press
and
to display “t-06” .
2. Press .
3. Press pedal to 1st step and No. lamp will turn on. Press
to 2nd step and you will see X-scale lamp be lit.
Pressing Aux 1 switch will turn on Y-scale lamp and
Aux 2 switch on speed lamp.
4. Press
to end the test.
SELECT
READY
–/BACK
+/FORWARD
(8) Testing Auxiliary Output
1. Run the Machine TEST and then press
and
to display “t-07” .
2. Press .
3. Press
to light on all of the 8 auxiliary output
(J11 on digital circuit board). Press
again to
turn off all of them.
4. Press
to end the test.
SELECT
READY
READY
READY
–/BACK
+/FORWARD
1st Step
2nd Step
Aux1 switch
Aux2 switch
Aux. output On/Off
End of test
(6) Testing Synchronizer
1. Run the Machine TEST and then press
and
to display “t-05” .
2. Press .
3. Rotate the pulley manually. The screen will display the
rotation number and the No. lamp will display synchro
signal.
◀
CAUTION
▶
No change in value after more than one rotation
means synchro-related errors including connector.
4. Press
to end the test.
SELECT
READY
–/BACK
+/FORWARD
No. of circulation