34
(9) Testing Auxiliary Input
1. Run the Machine TEST and then press
and
to display “t-08.”
2. Press .
3. Relevant lamps will be turned on according to the 8
auxiliary input signals (J9 on the digital circuit board).
4. Press
to end the test.
◀
CAUTION
▶
Inputting air pressure reduction only applies to
pneumatic type.
SELECT
READY
–/BACK
+/FORWARD
Aux8 input
Aux7 input
Aux6 input
Aux5 input
Aux4 input
Aux3 input
Aux2 input
Inputting the
external convering
of function key
(10) Clamp motor motion test
1. Run the Machine TEST and then press
and
to display “t-09” .
2. Press .
3. Press
to set the delay times for clamp moving
up and down. Use
and
keys
to change the delay time.
4. Press
to end the test.
RESET
–/BACK
+/FORWARD
SELECT
READY
–/BACK
+/FORWARD
Press pedal
Delay setup when the clamp
ascends
Delay setup when the clamp
descends