E. How to set upper thread holder in operation box
a) In order to use upper thread holder, set the Parameter NO. 62 at ENABLE.
- Setting Method:After turning the power on, press MODE KEY immediately.
b) After returning to general work by pressing ESC key twice, work normally.
c) However, upon performing thread inserting function by pressing key number 5 on condition of stop,
the upper thread holder opens.
After turning the power on, press MODE
KEY immediately.
Select Parameter Set by pressing key number
2 and press ENTER key.
< < M a i n M e n u > >
0 . I n i t i a l i z e
1 . P a r a m e t e r S e t
2 . P r o g r a m
Input “062”and press ENTER key.
< < Parameter Se t > >
P A R A N O : 0 0 0
Select ENABLE by pressing key number 2,
input and press ENTER key.
0 6 2 . T h r d H o l d E N
1 ) D I S A B L E
2 ) E N A B L E