W A R N I N G S 

 

 
ANY  ALTERATION  TO  THE  ORIGINAL  DESIGN,  INSTALLED  OTHER  THAN  AS  SHOWN  IN  THESE 
INSTRUCTIONS, OR USED WITH A TYPE OF GAS NOT SHOWN ON THE RATING PLATE IS PROHIBITED 
AND VOIDS THE WARRANTY. 

 

The  installation  must  conform  to  local  codes.    In  the  absence  of  local  codes,  the  installation  must 
conform  to  the  National  Fuel  Gas  Code,  also  known  as  NFPA  54  and  ANSI  Z223.1  -  latest  edition. 
Installation and service must be performed by a qualified installer (i.e., a licensed heating contractor 
or gas company personnel). 
Read this Installation and Owners Guide carefully and completely before attempting to install, operate 
or service this heater. Improper use of this heater can result in serious bodily injury or death due to 
hazards of fire, explosion, electrical shock or carbon monoxide poisoning.  When used without fresh 
air, this heater may give off  CARBON MONOXIDE, an odorless, poisonous gas.   CARBON MONOXIDE 
POISONING MAY LEAD TO DEATH!  Early signs of carbon monoxide poisoning resemble the flue with 
headache, dizziness and/or nausea.  If you have these signs, the heater may not be working properly.  
Get fresh air at once, and have the heater serviced.  Some people such as pregnant women, persons 
with heart or lung disease, anemia, those under the influence of alcohol, and those at higher altitudes 
are more affected by carbon monoxide than others.  Retain this manual for future reference.  It is your 
guide to many years of a proper and safer operation of the heater. 
 
1.  This is a heating appliance any safety screen 

or guard removed for servicing an appliance 
must  be  replaced  prior  to  operating  the 
appliance. 

2.  Children and adults should be alerted to the 

hazard  of  high  surface  temperatures  and 
should stay away to avoid burns or clothing 
ignition. 

3.  Young 

children 

should 

be 

carefully 

supervised  when  they  are  in  the  room  with 
the heater. 

4.  Do not install this heater at altitudes above 

5000 ft. because shutdown of the heater by 
the  ODS  system  may  occur  due  to  reduced 
oxygen levels at these altitudes. 

5.  This  appliance  is  only  for  use  with  the  type 

of  gas  indicated  on  the  nameplate.    THIS 
APPLIANCE  IS  NOT  CONVERTIBLE  FOR  USE 
WITH OTHER GASES.  Please check the gas 
type shown on the heater nameplate prior to 
hooking the heater to the gas supply. 

6.  DO NOT install this heater in bathrooms. The 

maximum  input  for  use  in  bathrooms  in 
6,000  Btu/hr  and  10,000  Btu/hr  in 
bedrooms  where  not  prohibited  by  local 
codes. 

7.  LPG containers (Propane cylinders) must not 

be used or stored indoors. 

8.  DO  NOT  install  this  heater  directly  onto  an 

LPG  container  or  propane  cylinder  without 
directions  from  your  propane  company 
because high gas pressure can damage this 

heater. 

9.  Always  operate  the  heater  at  the  OFF,  P  or 

one  of  the  three  locked  positions.    Never 
operate  the  heater  at  any  setting  between 
these locked positions, as this may result in 
improper combustion. 

10.  DO  NOT  locate  this  heater  in  high  traffic 

areas or in windy or drafty locations. 

11.  Keep  the  area  near  the  heater  free  from 

combustible  materials,  gasoline,  and  other 
flammable vapors and liquids. 

12.  DO NOT use this heater if any part has been 

under  water.    Immediately  call  a  qualified 
service  person  to  inspect  the  room  heater 
and  to  replace  any  part  of  the  control 
system  and  any  gas  control  that  has  been 
under water. 

13.  This  heater  has  a  pilot  light  safety  system 

that turns off the heater if enough fresh air 
is  not  available.    The  pilot  light  safety 
section  on  this  unit  does  not  sense  the 
presence of carbon monoxide.  It senses the 
depletion  of  the  oxygen  supply  used  in  the 
combustion  process.  Combustion  of  gas 
with a depleted oxygen supply is one source 
of carbon monoxide. 

14.  If this heater is installed in a room having a 

high  vertical  dimension,  a  fan  to  circulate 
the  air  is  recommended  to  improve  the 
comfort  level  in  the  room.    When  a  fan  is 
used to circulate air, it should be located so 
that the airflow is not directed at the burner. 

Содержание SC10T-1-LP

Страница 1: ...ance CONSUMER Retain this manual for future reference This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to the section titled Combustion and ventilation air requirement This appliance may be installed in an aftermarket permanently located manufactured mobile home where not pro...

Страница 2: ...t install this heater at altitudes above 5000 ft because shutdown of the heater by the ODS system may occur due to reduced oxygen levels at these altitudes 5 This appliance is only for use with the type of gas indicated on the nameplate THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES Please check the gas type shown on the heater nameplate prior to hooking the heater to the gas supply 6 ...

Страница 3: ...tu hr of gas consumption for the total input rating of all gas equipment in the space 18 This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fuel Gas Code or applicable codes 19 WARNING If the area in which the heater may be operated does not...

Страница 4: ..._ x 20 Btu hr ____________________ Btu hr STEP 3 Add the Btu hr inputs of all fuel burning appliances in this space NOTE DO NOT include Direct Vent gas appliances because these have sealed combustion systems that draw combustion air from outdoors Examples of appliances to consider include gas ranges gas water heaters gas logs kerosene heaters etc Proposed Vent Free Heater _________________________...

Страница 5: ... odorant in escaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If ...

Страница 6: ...hen facing the front of the heater the clearance from any combustible materials must be a minimum of 10 from the left 10 from the right 36 from the top and 2 from the bottom Never install the heater in front of any flammable object especially do not place curtains furniture clothing or other flammable objects less than 36 from the front of the heater FLOOR MOUNT INSTALLATION This heater is designe...

Страница 7: ...according to the dimensions shown on the upper corner of Figure 2 1 3 Drill another 5 16 hole on the wall stud for the lower mounting point 4 Screw in the three 3 plastic expansion anchors furnished with the unit as shown in Figure 2 1 5 Screw in the furnished screws to the anchors for the upper mounting points and hang the heater on the screws as shown in Figure 2 1 6 Fasten the bottom of the hea...

Страница 8: ... gas supply line shall be sized and installed to provide a sufficient supply of gas to meet the minimum demand of the heater without undue loss of pressure Typical Installation Supply Line Up to 20 000 Btu hr 3 8 or greater Up to 30 000 Btu hr 1 2 or greater 5 The sealant used on the threaded pipe joints of the gas pipe must be the specific type resistant to the action of Liquid Petroleum Gas Appl...

Страница 9: ...ating season If your pilot will not stay lit try cleaning it Use a can of compressed air such as is used to clean a computer to blow dust out of the pilot assembly Sometimes just blowing air back through the pilot will get rid of the dirt If that fails to solve the problem remove the wire clip that holds the metal strip onto the pilot assembly Remove the cover and blow any dust out Reassemble and ...

Страница 10: ... and it will pop back up Pilot should remain Iit If it goes out repeat steps 3 through 7 If knob does not pop up when released stop and inmediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to the OFF position and call your service technician or gas supplier 8 Attention Gas control has an INTERLOCK device When the pilo...

Страница 11: ...gas valve BURNER DOES NOT LIGHT Pilot stays lit Burner orifice clogged Burner orifices not correct size Extremely low inlet gas pressure Gas valve is defective Clean or replace orifices Replace with correct size Contact gas supplier Replace gas valve IMPROPER BURNER PATTERN Slight smoke or odor during initial operation Residues from manufacturing process or dust Problem will be eliminated after a ...

Страница 12: ...ater so that the solid portion of the base is facing towards the front of the heater using four 4 No 10 x 1 screws provided 4 Attach a field supplied pipe elbow 3 8 NPT thread to the bottom of the heater for connection to the gas line as shown in the figure below and as instructed previously in these instructions WARNING This heater must be installed on a wall whenever it is installed in a bedroom...

Страница 13: ... the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury REPAIR PARTS LIST MODELS SC10T 1 LP Propane Gas SC10T 1 NG Natural Gas ...

Страница 14: ...LS SC10T 1 LP Propane Gas SC10T 1 NG Natural Gas WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury ...

Страница 15: ...590050 Connector 10 43596010 43596010 Control Valve 11 43590050 43590050 Connector 12 43585830 43585830 Tubing Regulator to Tap 13 43585850 43585850 Tubing Valve to Distributor T 14 43585880 Tubing Valve to Pilot 15 43591010 43591010 Distributor T 16 43585840 43585840 Tubing Distributor T to First Setting 17 43585840 43585840 Tubing Distributor T to First Setting 18 43601070 43601070 Shoulder Ther...

Страница 16: ...15 Manufactured for SUNSTAR HEATING PRODUCTS INC 306 West Tremont Avenue Charlotte NC 28203 4946 704 372 3486 ...

Отзывы: