SunStar SC10T-1-LP Скачать руководство пользователя страница 15

 

-14- 

HOW TO ORDER REPAIR PARTS …  

 

All parts listed in the Parts List have a Part Number.  When ordering parts, first obtain the Model Number from the nameplate on your equipment.  Next, 
determine the Part Number (not the Index Number) and the Description of each part from the following appropriate illustration and list.  Be sure to give 
all this information. 

 

Heater Model Number:

 

 

Part Description:

 

 

Heater Serial Number:

 

 

Kind of Gas:

 

 

Part Number:

 

 

(Propane or Natural) 

 

 

Do not order bolts, screws, washers or nuts.  They are standard hardware items and can be purchased at any local hardware store.  Order parts from your 
local dealer or through Gas-Fired Products, Inc.  Shipments of parts are contingent upon strikes, fires, and all other causes beyond our control. 

 

REPAIR PARTS 

Index 

Number 

MODEL 

SC10T-1–LP 

MODEL 

SC10T-1–NG 

DESCRIPTION 

Propane Gas

 

Natural Gas

 

PART NUMBERS 

435740

9

0

                     4

3574070 

                 B

urner  

43575

21

0

                     4

3575180 

                 I

njector 

43597080 

43597080 

Screw 

------------------ 

------------------ 

 

43597140 

43597140 

Screw 

43584160 

43584170 

ODS System 

43576100 

43576110 

Regulator 

43597110 

43597110 

Screw 

43590050 

43590050 

Connector 

10 

43596010 

43596010 

Control Valve 

11 

43590050 

43590050 

Connector 

12 

43585830 

43585830 

Tubing – Regulator to Tap 

13 

43585850 

43585850 

Tubing – Valve to Distributor T 

14 

43585880 

----------------- 

Tubing – Valve to Pilot 

15 

43591010 

43591010 

Distributor T 

16 

43585840 

43585840 

Tubing – Distributor T to First Setting 

17 

43585840 

43585840 

Tubing – Distributor T to First Setting 

18 

43601070 

43601070 

Shoulder – Thermostatic Bulb 

19 

43601090 

43601090 

Retention Clip – Thermostatic Bulb 

20 

43601110 

43601110 

Thermostatic Valve Support 

21 

43597160 

43597160 

Screw 

22 

43597170 

43597170 

Screw 

23 

43587050 

43587050 

Thermostatic Valve Rod Adaptor 

24 

43588010 

43588010 

Pin 

25 

43710070 

43710070 

Thermostatic Control Enclosure 

26 

43586030 

43586030 

Control Knob 

27 

43587040 

43587040 

Control Rod 

28 

43573020 

43573020 

Piezo Igniter 

29 

43573060 

43573060 

Contact Piezo Igniter 

30 

43598020 

43598020 

Nut M-18 

31 

----------------- 

43585870 

Tubing – Pilot Regulator to Pilot 

32 

----------------- 

43585860 

Tubing – Valve to Pilot Regulator 

33 

------------------ 

43590060 

Connector 

34 

----------------- 

43576010 

Pilot Regulator 3.5” 

35 

43580270 

43580270 

Casing 

36 

43578070 

43578070 

Deflector 

37 

43597040 

43597040 

Screw 

38 

43708020 

43708020 

Washer 

39 

43597150 

43597150 

Screw 

40 

43579240 

43579240 

Screen 

41 

43581110 

43581110 

Safety Guard 

42 

43756000 

43756000 

Retention Clip 

 
 
 
 
 
 
 
 
 

Содержание SC10T-1-LP

Страница 1: ...ance CONSUMER Retain this manual for future reference This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to the section titled Combustion and ventilation air requirement This appliance may be installed in an aftermarket permanently located manufactured mobile home where not pro...

Страница 2: ...t install this heater at altitudes above 5000 ft because shutdown of the heater by the ODS system may occur due to reduced oxygen levels at these altitudes 5 This appliance is only for use with the type of gas indicated on the nameplate THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES Please check the gas type shown on the heater nameplate prior to hooking the heater to the gas supply 6 ...

Страница 3: ...tu hr of gas consumption for the total input rating of all gas equipment in the space 18 This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fuel Gas Code or applicable codes 19 WARNING If the area in which the heater may be operated does not...

Страница 4: ..._ x 20 Btu hr ____________________ Btu hr STEP 3 Add the Btu hr inputs of all fuel burning appliances in this space NOTE DO NOT include Direct Vent gas appliances because these have sealed combustion systems that draw combustion air from outdoors Examples of appliances to consider include gas ranges gas water heaters gas logs kerosene heaters etc Proposed Vent Free Heater _________________________...

Страница 5: ... odorant in escaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If ...

Страница 6: ...hen facing the front of the heater the clearance from any combustible materials must be a minimum of 10 from the left 10 from the right 36 from the top and 2 from the bottom Never install the heater in front of any flammable object especially do not place curtains furniture clothing or other flammable objects less than 36 from the front of the heater FLOOR MOUNT INSTALLATION This heater is designe...

Страница 7: ...according to the dimensions shown on the upper corner of Figure 2 1 3 Drill another 5 16 hole on the wall stud for the lower mounting point 4 Screw in the three 3 plastic expansion anchors furnished with the unit as shown in Figure 2 1 5 Screw in the furnished screws to the anchors for the upper mounting points and hang the heater on the screws as shown in Figure 2 1 6 Fasten the bottom of the hea...

Страница 8: ... gas supply line shall be sized and installed to provide a sufficient supply of gas to meet the minimum demand of the heater without undue loss of pressure Typical Installation Supply Line Up to 20 000 Btu hr 3 8 or greater Up to 30 000 Btu hr 1 2 or greater 5 The sealant used on the threaded pipe joints of the gas pipe must be the specific type resistant to the action of Liquid Petroleum Gas Appl...

Страница 9: ...ating season If your pilot will not stay lit try cleaning it Use a can of compressed air such as is used to clean a computer to blow dust out of the pilot assembly Sometimes just blowing air back through the pilot will get rid of the dirt If that fails to solve the problem remove the wire clip that holds the metal strip onto the pilot assembly Remove the cover and blow any dust out Reassemble and ...

Страница 10: ... and it will pop back up Pilot should remain Iit If it goes out repeat steps 3 through 7 If knob does not pop up when released stop and inmediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to the OFF position and call your service technician or gas supplier 8 Attention Gas control has an INTERLOCK device When the pilo...

Страница 11: ...gas valve BURNER DOES NOT LIGHT Pilot stays lit Burner orifice clogged Burner orifices not correct size Extremely low inlet gas pressure Gas valve is defective Clean or replace orifices Replace with correct size Contact gas supplier Replace gas valve IMPROPER BURNER PATTERN Slight smoke or odor during initial operation Residues from manufacturing process or dust Problem will be eliminated after a ...

Страница 12: ...ater so that the solid portion of the base is facing towards the front of the heater using four 4 No 10 x 1 screws provided 4 Attach a field supplied pipe elbow 3 8 NPT thread to the bottom of the heater for connection to the gas line as shown in the figure below and as instructed previously in these instructions WARNING This heater must be installed on a wall whenever it is installed in a bedroom...

Страница 13: ... the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury REPAIR PARTS LIST MODELS SC10T 1 LP Propane Gas SC10T 1 NG Natural Gas ...

Страница 14: ...LS SC10T 1 LP Propane Gas SC10T 1 NG Natural Gas WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury ...

Страница 15: ...590050 Connector 10 43596010 43596010 Control Valve 11 43590050 43590050 Connector 12 43585830 43585830 Tubing Regulator to Tap 13 43585850 43585850 Tubing Valve to Distributor T 14 43585880 Tubing Valve to Pilot 15 43591010 43591010 Distributor T 16 43585840 43585840 Tubing Distributor T to First Setting 17 43585840 43585840 Tubing Distributor T to First Setting 18 43601070 43601070 Shoulder Ther...

Страница 16: ...15 Manufactured for SUNSTAR HEATING PRODUCTS INC 306 West Tremont Avenue Charlotte NC 28203 4946 704 372 3486 ...

Отзывы: