54
(2) Group B Parameter : All types of output, Full-on Time/PWM Duty, checking input/output operations, sewing
machine models and thread trimming sequence programming.
These are functions not used by general users and must be regulated by an A/S technician.
No.
Function
Step
Range
Initial value
[ Caution ]
If the specific items of the parameter are changed carelessly, they could break down or damage the machine, so the user must be
well-trained before using it.
Items No. 30~33 : These are the items that make the number of stitches match when back tack number of stitches do not match.
Solenoid Duty Ratio : The power that holds and maintains the solenoid.
Solenoid initial full on time : The time it takes to pull the solenoid to the maximum in the outset.
1
Back Tack Solenoid Initial Full On Time
1020ms
4~1020
4ms
2
Presser Foot-Lift Solenoid Initial Full On Time
200ms
4~1020
4ms
3
T/T Solenoid Initial Full On Time
100ms
4~1020
4ms
4
Wiper Solenoid Initial Full On Time
100ms
4~1020
4ms
5
Tension Release Solenoid Initial Full On Time
100ms
4~1020
4ms
6
Left Solenoid Initial Full On Time (For Twin Needle)
100ms
4~1020
4ms
7
Right Solenoid Initial Full On Time (For Twin Needle)
100ms
4~1020
4ms
8
Auxiliary Solenoid Initial Full On Time
100ms
4~1020
4ms
9
Left LED Initial Full On Time (For Twin Needle)
100ms
4~1020
4ms
10
Right LED Initial Full On Time (For Twin Needle)
100ms
4~1020
4ms
11
Needle plate up-stop signal Initial Full On Time
100ms
4~1020
4ms
12
Needle plate down-stop signal Initial Full On Time
100ms
4~1020
4ms
13
Signal notifying motor running Full On Time
100ms
4~1020
4ms
14
Signal notifying target speed achieved Full On Time
100ms
4~1020
4ms
15
Back Tack Solenoid Duty Ratio
50%
0~100
10%
16
Presser Foot-Lift Solenoid Duty Ratio
20%
0~100
10
17
Thread Trimming Solenoid Duty Ratio
100
0~100
10
18
Wiper Solenoid Duty Ratio
100
0~100
10
19
Tension Release Solenoid Duty Ratio
100
0~100
10
20
Left Solenoid Duty Ratio (For Twin Needle)
50
0~100
10
21
Right Solenoid Duty Ratio (For Twin Needle)
50
0~100
10
22
Aux Solenoid Duty Ratio
100
0~100
10
23
Left LED Duty Ratio (For Twin Needle)
100
0~100
10
24
Right LED Duty Ratio (For Twin Needle)
100
0~100
10
25
Signal for up stopping needle Duty Ratio
100
0~100
10
26
Signal for low stopping needle Duty Ratio
100
0~100
10
27
Signal notifying motor running Duty Ratio
100
0~100
10
28
Signal notifying target speed reached Duty Ratio
100
0~100
10
29
NOT USED
30
Start Back Tack A number of stitches correction value
00.30
6~6
0.05 Stitch
31
Start Back Tack B number of stitches correction value
00.30
6~6
0.05 Stitch
32
End Back Tack C stitch correction value
00.40
6~6
0.05 Stitch
33
End Back Tack D stitch correction value
00.40
6~6
0.05 Stitch
34
Selection for maintaining reverse solenoid movement when thread trimming (C Only B/T)
0
0/1
1=reverse direction maintained
35
Programming count condition
0
0/1
0=counter used
(program whether or not automatic counter will be operated)
1=automatic counter after thread trimming
36
When automatically counting, select Up/Down count after thread
1
0/1
1=Up COUNT
trimming (thread trimming function must be enabled)
0=DOWN COUNT
0=buzzer rings, sewing is allowed
37
When count in completeded, the next operation is programmed
0
0/1/2
1=buzzer rings, sewing is not allowed
(If you press the Prog Key, set up is cancelled)
2=No buzzer ring, sewing is allowed
38
When count is completed, select the counter auto clear/preset
0
0/1
1=AUTO
CLEAR/PRESET
39
Bobbin counter set-up
0
0/1
0=Bobbin counter Disable
1=Bobbin counter Enable