Model CK18M = (13-5/32 )    334mm
Model CK30M = (20-45/64 )  526mm

Min 15  380mm

Figure 2-1

BACK OF

HEATER

Min 22 5

5

5mm

20-

2/3

(5

12mm)

left side

Right side

Figure 2-2

Manual shut off valve

Gas line

Frank

U  Hook

opening for combustion air

WALL MOUNT INSTALLATION

IMPORTANT: 

 

Before installing this heater, make sure that a wall stud is located in the center of the

unit.  This wall stud will give better support to the unit

.  See the following instructions in

figure 2.2 to place the “C” angle to the wall stud:

1.

Select the elbow position as indicated in Figure 2-1.

2.

Use the template provided to mark out the hole locations.

3.

Drive two (2) 5/16” holes according to the dimensions shown on the upper corner of Figure 2-1.

4.

Drill another 5/16” hole on the wall stud for the “U” hook as shown in Figure 2-1.

5.

Screw in the three (3) plastic expansion anchors furnished with the unit, as shown in Figure 2-1.

6.

Screw in the furnished screws through the upper anchors as shown in Figure 2-1.

7.

Hang the appliance and screw the “U” hook to the wall with the furnished screw as shown in figure 2.2

8.

Connect the gas line.

Содержание CK18M-4-LP

Страница 1: ...alified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean PN 43126170 INSTALLATION AND OWNER S GUIDE Effective Date June 2006 V...

Страница 2: ...e and other flammable vapors and liquids 11 This appliance may be installed in an aftermarket manufactured mobile home where not prohibited by state or local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer 12 DO NOT use this heater if any part has been under water Immediately call a qualified service person to inspect the room heater and to replace any part of ...

Страница 3: ...ine the volume of the space in which the heater is to be installed Include adjoining rooms with doorless passageways Example 24 long x 16 wide x 8 high 3072 ft3 LE NGTH x WI DTH x H E IG HT ___________________________ Ft3 STEP 2 Multiply the volume of the space calculated in Step 1 by 20 BTU hr to determine the maximum BTU hr that the space can support without additional combustion and ventilation...

Страница 4: ...nside the storage tank or in iron gas pipes The odorant in escaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Al...

Страница 5: ...eater The heater must be installed no less than 2 above the top surface of carpeting tile or other floor covering When facing the front of the heater the clearance from any combustible materials must be a minimum of 13 from the left 13 from the right 36 from the top and 2 from the bottom and 36 from the front The opening for combustion air located at the bottom of the heater must not be obstructed...

Страница 6: ...the unit See the following instructions in figure 2 2 to place the C angle to the wall stud 1 Select the elbow position as indicated in Figure 2 1 2 Use the template provided to mark out the hole locations 3 Drive two 2 5 16 holes according to the dimensions shown on the upper corner of Figure 2 1 4 Drill another 5 16 hole on the wall stud for the U hook as shown in Figure 2 1 5 Screw in the three...

Страница 7: ...e forced into the pipe and result in clogged gas valves 6 The supply system must include a manual shut off valve a union in the line and a plugged 1 8 NPT tap The tap should be accessible for test gauge connections upstream of the gas supply connection to heater 7 Include a drip leg trap in the supply line The purpose of the drip leg is to prevent moisture and contaminants in the gas supply from e...

Страница 8: ...f your pilot will not stay lit try cleaning it Use a can of compressed air such as is used to clean a computer to blow dust out of the pilot assembly Sometimes just blowing air back through the pilot will get rid of the dirt If that fails to solve the problem remove the wire clip that holds the metal strip onto the pilot assembly Remove the cover and blow any dust out Reassemble and check for prop...

Страница 9: ...ic switch do not use any telephone in your building Immediately call your gas supplier from a neighbor s telephone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it Call a qualified service person Force...

Страница 10: ...etting OFF OFF P 1 2 3 MODEL TYPES CK18M 4 NG CK18M 4 LP PIEZO IGNITOR PIEZO IGNITOR MODEL TYPES CK 30M 4 NG CK 30M 4 LP BURNER LIGHTING SEQUENCE one radiant Setting 1 O FF P 1 2 3 Setting 2 Three radiant O F F P 1 2 3 one radiant Setting 1 O FF P 1 2 3 one radiant Setting 2 O F F P 1 2 3 Setting 3 O F F P 1 2 3 two radiants Setting 3 Five radiants O F F P 1 2 3 ...

Страница 11: ...ction firmly Replace thermocouple Replace gas valve BURNER DOES NOT LIGHT Pilot stays lit Burner orifice clogged Burner orifices not correct size Extremely low inlet gas pressure Gas valve is defective Clean or replace orifices Replace with correct size Contact gas supplier Replace gas valve IMPROPERBURNERPATTERN Slight smoke or odor during initial operation Residues from manufacturing process or ...

Страница 12: ...sunstar corcho T Convertido 1 13 3 08 10 27 P gina 12 Composici n C M Y CM MY CY CMY K 12 MODELS CK18M 4 LP Propane Gas CK18M 4 NG Natural Gas 1 22 2 3 4 5 6 7 16 15 17 18 21 19 20 14 30 28 29 27 ...

Страница 13: ...r corcho T Convertido 1 13 3 08 10 27 P gina 13 Composici n C M Y CM MY CY CMY K 13 30 21 19 20 18 17 16 15 14 13 11 9 12 10 9 8 7 4 6 2 5 1 27 28 29 CK30M 4 LP Propane Gas CK30M 4 NG Natural Gas 23 24 25 26 ...

Страница 14: ...sunstar corcho T Convertido 1 13 3 08 10 27 P gina 14 Composici n C M Y CM MY CY CMY K 14 MODELS CK18M 4 LP and CK30M 4 LP Propane Gas CK18M 4 NG and CK30M 4 NG Natural Gas 32 33 34 35 36 37 38 39 40 41 ...

Страница 15: ...1 4359101 T Connector CK30M 11 4358559 4358559 Tubing Valve Third Setting 12 4358558 4358558 Tubing valve first setting 13 4358563 4358563 Tubing Third Setting Right 14 4358564 4358564 4358564 4358564 Tubing Regulator to Valve 15 4359601 4358900 4359601 4358900 Valve 16 4358560 4358505 Tubing Valve to ODS 17 4358800 4358800 4358800 4358800 Cotter Clip 18 4360001 4360001 4360001 4360001 Valve Suppo...

Страница 16: ...sunstar corcho T Convertido 1 13 3 08 10 27 P gina 16 Composici n C M Y CM MY CY CMY K 16 PN 43126170 22 130 177 Rev d ...

Отзывы: