sunstar corcho T (Convertido)-1 13/3/08 10:27 P gina 5
Composici n
C
M
Y
CM
MY
CY CMY
K
5
MODEL
CK18M-4-NG
MODEL
CK 18M-4-LP
MODEL
CK30M-4-NG
MODEL
CK30M-4-LP
BTU/hr Input:
Type Gas:
Ignition Type:
Temp. Control:
Weight
Heater:
Shipping:
Inlet Gas Pressure
Maximum:
Minimum:
Regulator Setting:
Dimensions
(inches)
(W”
x
D”
x
H”)
Heater:
Carton:
18,000
Natural Gas
Piezo ignitor
Manual
20 lb.
24 lb.
14.0" W.C.
7.0" W.C.
6.0" W.C.
19-1/4x9-1/4x23-3/4
21-5/8x10-5/8x26
16,500
LP Gas
Piezo ignitor
Manual
20 lb.
24 lb.
14.0" W.C.
11.0" W.C.
10.0" W.C.
19-1/4x9-1/4x23-3/4
21-5/8x10-5/8x26
30,000
Natural Gas
Piezo ignitor
Manual
27 lb.
32 lb.
14.0" W.C.
7.0" W.C
6.0" W.C.
26-3/4x9-1/4x23-3/4
29-1/8x10-5/8x26
27,000
LP Gas
Piezo ignitor
Manual
27 lb.
32 lb,
14.0" W.C.
11.0" W.C.
10.0" W.C.
26-3/4x9-1/4x23-3/4
29-1/8x10-5/8x26
CLEARANCES
You must provide adequate clearance around air openings to the heater. You also must provide for an
adequate combustion and ventilation air supply to the space to be heated. The heater must be easily
accessible for servicing.Never install the heater in front of any flammable object, especially do not place
curtins, furniture, clothing or other flammable objects less thar 36” from the front of the heater.
The heater must be installed no less than 2” above the top surface of carpeting, tile or other floor covering.
When facing the front of the heater, the clearance from any combustible materials must be a minimum of 13”
from the left, 13” from the right, 36” from the top, and 2” from the bottom and 36” from the front. The opening
for combustion air located at the bottom of the heater must not be obstructed. The front must be free of
obstacles.
FLOOR MOUNT INSTALLATION
(When using the optional legs for models CK18M and CK30M)
This heater is designed to be installed on the floor with the leg set that is included with each heater.
Locate the leg set and attach the legs to the heater as noted on page 14. Screw in elbows A and B with
sealing tape as shown in Figure 1 below.
If this heater is to be installed directly on carpeting, light-colored tile or other combustible material other than
wood flooring, the heater shall be installed on a metal or wood panel extending the full width and depth of
the heater. All other clearances to combustible materials stated above must be maintained.Floor protection
panels ( 44058010) are available as an accessory.
This protective panel referred to above is not required as a fireproof base as used on wood stoves. The
protection is for rugs that are extremely thick and light-colored tile that may discolor and to make sure the
heater is level.
Figure 1
A
B