Propane (LP-Gas) is a flammable gas that can cause
fires and explosions.  In its natural state, propane is
odorless and colorless.  You may not know all the
following safety precautions, which can protect both
you and your family from an accident.  Read them
carefully now, then review them point by point with

the members of your household. Someday when
there may not be a minute to lose, everyone's safety
will depend on knowing exactly what to do.  If, after
reading the following information, you feel you still
need more information, please contact your gas
supplier.

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas.

That’s your signal to go into immediate action!

¥

Do not operate electric switches, light matches, or
use your telephone.  Do not do anything that could
ignite the gas.

¥

Get everyone out of the building, vehicle, trailer or
area. Do that 

IMMEDIATELY.

¥

Close all gas tank or cylinder supply valves.

¥

LP-Gas is heavier than air and may settle in low
areas such as basements.  When you have reason
to suspect a gas leak, keep out of basements and
other low areas. Stay out until firefighters declare
them safe.

¥

Use your neighbor's telephone and call a trained
LP-Gas service person and the fire department.
Even though you may not continue to smell gas, do
not turn on the gas again.  Do not re-enter the
building, vehicle, trailer or area.

¥

Finally, let the service man and firefighters check for
escaped gas.  Have them air out the area before
you return.  Properly trained LP-Gas service people
should repair the leak, then check and relight the
gas appliance for you.

NO ODOR DETECTED - ODOR FADE

SOME POINTS TO REMEMBER

Some people cannot smell well.  Some people cannot
smell the odor of the chemical stench put into the gas.
You must find out if you can smell the odorant in propane.
 Smoking can decrease your ability to smell.  Being
around an odor for a time can affect your sensitivity or
ability to detect that odor.  Sometimes other odors in the
area mask the gas odor.  People may not smell the gas
odor or their minds are on something else.  Thinking
about smelling a gas odor can make it easier to smell.

The odorant in LP-Gas is colorless, and it can fade under
some circumstances.  For example, if there is an
underground leak, the movement of the gas through soil
can filter the odorant.

Odorants in LP-Gas also are subject to oxidation.  Odor
fading can occur if there is rust inside the storage tank
or in iron gas pipes.

The odorant in escaped gas can adsorb or absorb onto
or into walls, masonry and other materials and fabrics in
a room.  That will take some of the odorant out of the
gas, reducing its odor intensity.

LP-Gas may stratify in a closed area, and the odor intensity
could vary at different levels.  Since it is heavier than air,
there may be more odor at lower levels.  Always be
sensitive to the slightest gas odor.  If you detect any
odor, treat it as a serious leak.  Immediately go into action
as instructed above.

Learn to recognize the odor of LP-Gas.  Your local
LP-Gas Dealer can give you a "Scratch and Sniff"
pamphlet.  Use it to find out what the propane odor
smells like.  If you suspect that your LP-Gas has a
weak or abnormal odor, call your LP-Gas Dealer.

If you are not qualified, do not light pilot lights,
perform service, or make adjustments to appliances
on the LP-Gas system.  If you are qualified,
consciously think about the odor of LP-Gas prior to
and while lighting pilot lights or performing service
of making adjustments.

Sometimes a basement or a closed-up house has
a musty smell that can cover up the LP-Gas odor.
Do not try to light pilot lights in the area where the
conditions are such that you may not detect the odor
if there has been a leak of LP-Gas.

Odor fade, due to oxidation by rust or absorption on
walls of new cylinders and tanks, is possible.
Therefore, people should be particularly alert and
careful when new tanks or cylinders are placed in
service.  Odor fade can occur in new tanks, or
reinstalled old tanks, if they are filled and allowed
to sit too long before refilling. Cylinders and tanks

that have been out of service for a time may develop
internal rust, which will cause odor fade.  If such
conditions are suspected  to  exist,  a  periodic  sniff
test of the gas is advisable.  If you have any question
about the gas odor, call your LP-Gas dealer.  A
periodic sniff test of the LP-Gas is a good safety
measure under any condition.

If, at any time, you do not smell the LP-Gas odorant
and you think you should, assume you have a leak.
 Then take the same immediate action recommended
above for the occasion when you do detect the
odorized LP-Gas.

If you experience a complete "gas out" (the container
is under no vapor pressure), turn the tank valve off
immediately.  If the container valve is left on, the
container may draw in some air through openings
such as pilot light orifices.  If this occurs, some new
internal rusting could occur.  If the valve is left open,
then treat the container as a new tank.  Always be
sure your container is under vapor pressure by turning
it off at the container before it goes completely empty
or having it refilled before it is completely empty.

Содержание CK18M-4-LP

Страница 1: ...alified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean PN 43126170 INSTALLATION AND OWNER S GUIDE Effective Date June 2006 V...

Страница 2: ...e and other flammable vapors and liquids 11 This appliance may be installed in an aftermarket manufactured mobile home where not prohibited by state or local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer 12 DO NOT use this heater if any part has been under water Immediately call a qualified service person to inspect the room heater and to replace any part of ...

Страница 3: ...ine the volume of the space in which the heater is to be installed Include adjoining rooms with doorless passageways Example 24 long x 16 wide x 8 high 3072 ft3 LE NGTH x WI DTH x H E IG HT ___________________________ Ft3 STEP 2 Multiply the volume of the space calculated in Step 1 by 20 BTU hr to determine the maximum BTU hr that the space can support without additional combustion and ventilation...

Страница 4: ...nside the storage tank or in iron gas pipes The odorant in escaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Al...

Страница 5: ...eater The heater must be installed no less than 2 above the top surface of carpeting tile or other floor covering When facing the front of the heater the clearance from any combustible materials must be a minimum of 13 from the left 13 from the right 36 from the top and 2 from the bottom and 36 from the front The opening for combustion air located at the bottom of the heater must not be obstructed...

Страница 6: ...the unit See the following instructions in figure 2 2 to place the C angle to the wall stud 1 Select the elbow position as indicated in Figure 2 1 2 Use the template provided to mark out the hole locations 3 Drive two 2 5 16 holes according to the dimensions shown on the upper corner of Figure 2 1 4 Drill another 5 16 hole on the wall stud for the U hook as shown in Figure 2 1 5 Screw in the three...

Страница 7: ...e forced into the pipe and result in clogged gas valves 6 The supply system must include a manual shut off valve a union in the line and a plugged 1 8 NPT tap The tap should be accessible for test gauge connections upstream of the gas supply connection to heater 7 Include a drip leg trap in the supply line The purpose of the drip leg is to prevent moisture and contaminants in the gas supply from e...

Страница 8: ...f your pilot will not stay lit try cleaning it Use a can of compressed air such as is used to clean a computer to blow dust out of the pilot assembly Sometimes just blowing air back through the pilot will get rid of the dirt If that fails to solve the problem remove the wire clip that holds the metal strip onto the pilot assembly Remove the cover and blow any dust out Reassemble and check for prop...

Страница 9: ...ic switch do not use any telephone in your building Immediately call your gas supplier from a neighbor s telephone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it Call a qualified service person Force...

Страница 10: ...etting OFF OFF P 1 2 3 MODEL TYPES CK18M 4 NG CK18M 4 LP PIEZO IGNITOR PIEZO IGNITOR MODEL TYPES CK 30M 4 NG CK 30M 4 LP BURNER LIGHTING SEQUENCE one radiant Setting 1 O FF P 1 2 3 Setting 2 Three radiant O F F P 1 2 3 one radiant Setting 1 O FF P 1 2 3 one radiant Setting 2 O F F P 1 2 3 Setting 3 O F F P 1 2 3 two radiants Setting 3 Five radiants O F F P 1 2 3 ...

Страница 11: ...ction firmly Replace thermocouple Replace gas valve BURNER DOES NOT LIGHT Pilot stays lit Burner orifice clogged Burner orifices not correct size Extremely low inlet gas pressure Gas valve is defective Clean or replace orifices Replace with correct size Contact gas supplier Replace gas valve IMPROPERBURNERPATTERN Slight smoke or odor during initial operation Residues from manufacturing process or ...

Страница 12: ...sunstar corcho T Convertido 1 13 3 08 10 27 P gina 12 Composici n C M Y CM MY CY CMY K 12 MODELS CK18M 4 LP Propane Gas CK18M 4 NG Natural Gas 1 22 2 3 4 5 6 7 16 15 17 18 21 19 20 14 30 28 29 27 ...

Страница 13: ...r corcho T Convertido 1 13 3 08 10 27 P gina 13 Composici n C M Y CM MY CY CMY K 13 30 21 19 20 18 17 16 15 14 13 11 9 12 10 9 8 7 4 6 2 5 1 27 28 29 CK30M 4 LP Propane Gas CK30M 4 NG Natural Gas 23 24 25 26 ...

Страница 14: ...sunstar corcho T Convertido 1 13 3 08 10 27 P gina 14 Composici n C M Y CM MY CY CMY K 14 MODELS CK18M 4 LP and CK30M 4 LP Propane Gas CK18M 4 NG and CK30M 4 NG Natural Gas 32 33 34 35 36 37 38 39 40 41 ...

Страница 15: ...1 4359101 T Connector CK30M 11 4358559 4358559 Tubing Valve Third Setting 12 4358558 4358558 Tubing valve first setting 13 4358563 4358563 Tubing Third Setting Right 14 4358564 4358564 4358564 4358564 Tubing Regulator to Valve 15 4359601 4358900 4359601 4358900 Valve 16 4358560 4358505 Tubing Valve to ODS 17 4358800 4358800 4358800 4358800 Cotter Clip 18 4360001 4360001 4360001 4360001 Valve Suppo...

Страница 16: ...sunstar corcho T Convertido 1 13 3 08 10 27 P gina 16 Composici n C M Y CM MY CY CMY K 16 PN 43126170 22 130 177 Rev d ...