Specifications 

Model 

ET20 

ET30 

Number of Tubes 

20 

30 

Dimensions

L×W×H

 

2050×1400×153 

2050×2100×153 

Effectual Absorb Area 

1.62m

2

 

2.42m

2

 

Weight

Empty

 

63kgs 

94kgs 

Manifold’s Capacity 

1.15L 

1.7L 

Connections 

G3/4" male thread 

G3/4"male thread 

Components  

1.

 

Heat Pipe  

Transfers the thermal energy from within the vacuum tube to the condenser efficiently and 
rapidly

 

2.

 

Glass tube top holder 

The Part to hold the glass tubes to the manifold box

 

3.

 

Cover 

Stabilises the heat pipe and minimises the thermal energy loss from the glass tube

 

4.

 

Conductive Aluminium fins 

Transfer the thermal energy from the glass inner wall to the heat pipe more efficiently; 

5.

 

Vacuum layer between the glass skins; 

6.

 

Solar glass tube 

High efficiency solar glass tube with maximum radiation absorption, minimum thermal 
radiation losses and high insulation performance

 

7.

 

Base / tube seal 

This section has a mirror finish to minimise heat loss in the vacuum layer seal zone.   

 

 

 

 

Parameters

 

Solar collector tube parameters 

Absorptivity 

Emissivity 

Glass 

transmission 

Vacuum 

Tiptop temp. 

Low temp. 

durability 

Wind 

durability 

≥92

 

≤10

 

≥92

 

≤5×10

-2

Pa 

250

 

—35

 

30m/s 

 

Содержание Evacuated Tube Solar Water Heater

Страница 1: ...Tube Solar Water Heaters Sunshine Solar water heaters are AS NZ 2712 2007 certified Please read the following instructions carefully to ensure their correct installation for optimum results If you hav...

Страница 2: ...to the cylinder Contents Page 3 Section 1 Specifications and cautions 6 Section 2 General guidelines for roof mounting of the solar collectors 7 Section 3 Collector assembly 9 Section 4 Frame assembl...

Страница 3: ...Copyright 2013 0800 sunshine john sunshinesolar co nz www sunshinesolar co nz 3 Section 1 Specifications and cautions Dimensions of the solar collectors ET20 20 tube and ET30 30 tube ET20 ET30...

Страница 4: ...s to the manifold box 3 Cover Stabilises the heat pipe and minimises the thermal energy loss from the glass tube 4 Conductive Aluminium fins Transfer the thermal energy from the glass inner wall to th...

Страница 5: ...licable Health and Safety guidelines at all time 1 7 The solar collector should be installed within 22 500 angle 1 8 The weight bearing capacity of the roof MUST be calculated for the maximum collecto...

Страница 6: ...a frame to maximise the collector efficiency Clients will have a view on the use of a frame it is important to explain to them in writing that Sunshine Solar does recommend a frame in these circumsta...

Страница 7: ...g each other ET30 only For the central vertical frame piece ONLY place the top clip at this stage 1a Vertical tracks the manifold end has the holes for the brackets further apart picture showing manif...

Страница 8: ...cap has NOT clipped in securely as in the photo the manifold will have to be adjusted up to allow the end cap to click into place 8 Now the manifold clips can be tightened ON THIS SIDE ONLY because t...

Страница 9: ...on 3 should be cut to the desired length Both sections must be fitted to the collector frame using the stainless steel M8 bolts provided The bolt holes should be drilled carefully to avoid scarring th...

Страница 10: ...Copyright 2013 0800 sunshine john sunshinesolar co nz www sunshinesolar co nz 10 Section 5 Roof fixings...

Страница 11: ...er see diagram 7 Ensure the pump has enough support and is installed in a vertical position accessible for replacement and adjustment of settings 8 Connect Tempering valve if required to hot and cold...

Страница 12: ...e control 8 Connect power to controller relay is a switch do NOT connect an outside live to relay 9 Switch on and test 10 For overheat dump option connect pipe thermostat live comes from P1 connection...

Страница 13: ...irmly and completely into the manifold 3 Next slide the loose copper collar up 4 Slide up the black plastic tube mount which then screws firmly onto the manifold 5 Then ease the evacuated tube gently...

Страница 14: ...press SET and then to make this 0100 press set twice until it has a temperature 40 Press plus to increase this to 50 Press ESC then display should say TH1F change this to 0700 and 60C in the same way...

Страница 15: ...lted it Ensure that copper is used where this can occur NB heat can travel up the cold supply pipe when the whole cylinder is HOT May require thermal trap on the cold supply bare copper pipe in a loop...

Страница 16: ...el 1 and 2 frost protection if in areas of long term below zero temperatures a closed loop system is advised D Guards to the collectors may be required in areas of vandalism or large hail zones Sydney...

Страница 17: ...eview controller settings Clean up the site from boxes wires etc Important Paperwork Complete Code of Compliance for council Complete Council specific PS3 documentation Complete warranty details in Ow...

Отзывы: