background image

119832Rev. G

26

Q UI C KI E   PU LS E

F.  PERFORMANCE CONTROL SETTINGS

NOTE– BEFORE attempting to check and/or adjust settings on your joy-

stick, be sure to see  your Dealer or Clinician and have them
make the adjustments if needed.

1. It is vital to match control settings to your level of function

and ability. 

2. Consult your health care professional and your Authorized

Dealer to select the best control settings for you. 

3. Check and adjust the settings every six to twelve months. 

WARNING

Adjust the control settings immediately if you notice any change in
your ability to: 

• Control the joystick. 
• Avoid running into objects.

G. ON BOARD PROGRAMMER (DIAGNOSTIC
TEST TOOL) OR RNET PC PROGRAMMER

(Optional)

WARNING

Program settings beyond the ability of the user can result in seri-
ous injury. Consult your health care advisor before you alter set-
tings.

The On-board Programmer or RNET PC Programmer lets you
adjust the control settings of the QM-710. Listed below are a few
of the many settings that can be adjust via the On-board
Programmer or RNET PC Programmer. (See RNET OBP Owners
Manual for full programmable parameters.)

acceleration rate

deceleration rate

turn acceleration

turn deceleration

forward speed (max & min)

reverse speed (max & min)

turn speed (max & min)

steer correct

Programming the Chair: 

a. Access via DTT (Diagnostic Test Tool), or the PC

Programmer require an inline 
connection to the communication cable.

b. Program  as needed. 
c. Remove Dongle or recycle power.

NOTE– 

Review the RNET OBP Owner’s Manual for more details on how

to program your chair.

H. CTRL+5 ASSIGNABLE BUTTONS

The Ctrl+5 (Canbus switch) is a device that plugs into the PG
Drives R-net system and allows for the set up of up to ten differ-
ent functions into the ten discrete buttons, (each toggle switch is
two buttons).  This device uses the Sunrise Medical patented
Assignable Buttons feature.  The Ctrl+5 switches are pre-pro-
grammed from the factory to default values for the actuators on
the chairs.  Using the Dealer PC Programmer and dongle, the but-
ton assignments can be changed to any of the Assignable Buttons
functions to suit the user just like the joystick buttons.

I.    JOYSTICK STATIONARY

Your chair has an available programming feature called “Joystick
Stationary” which can be set by your dealer. This feature senses
when the joystick is displaced from neutral, yet left in a steady posi-
tion for a predetermined period of time. The controller will auto-
matically turn off if the set time has been reached. This feature is
designed to protect the user, batteries and electronics if the joystick
is inadvertently displaced. There are two parameters that can be
adjusted:

1.

Joystick Stationary Time

:

This is the time the joystick has to remain within the sta-
tionary range before the unit will come to a stop. It can be
programmed from 0 to 60 minutes in steps of one minute.
Select 0 to disable the function. Default setting is 0
(Disabled).

2.

Joystick Stationary Range

:

This determines the size of a region around the present joy-
stick position. If the joystick remains within this region for the
stationary time the controller will stop. The range can be pro-
grammed from 1 to 50, in steps of 1. Default setting is 1.

WARNING

Before turning on or adjusting these parameters, carefully read
and understand the implications for use of these features, Joystick
Stationary Time and Joystick Stationary Range. When the “Joystick
Stationary Time” is reached within the “Joystick Stationary Range”,
the drive motors on the chair will shut off. As an example, this will
happen while driving in a straight line for extended periods of time
with no joystick movement. Once the drive motors turn off, the
user will need to turn the chair off and back on to drive.

J.   THERMAL ROLL-BACK 

Your chair has a thermal roll back circuit. This protects the con-
troller from damage due to overheating. In extreme conditions (such
as repetitive hill climbing) the circuit will decrease the power to your
motors. This allows the chair to operate at a reduced speed. When
the controller cools, the chair will return to normal speed.

K. RECLINE, TILT & LIFT OPERATION 

The tilt and lift features on your chair can all be operated using the
joystick on your chair. Follow the instructions below to operate:  

If the thru drive option was selected,

1. Make sure your controller is on.
2. From the Drive Mode, press the Mode button to enter

Power Seating Mode.

3. Move the joystick left or right selecting the power option

(recline, tilt, lift, legrests) you wish to control.

4. Move the joystick forward or backward to adjust the select-

ed power option to the desired position.

5. Press the Mode button to return to normal operation or

continue moving the joystick left or right to adjust the next
power option. Multiple Mode button presses will be neces-
sary if other modules, such as Output, are active.

53

53

A

IX. CONTROLLER, JOYSTICKS, & OPERATING GUIDE

Содержание Pulse 5BC

Страница 1: ...ble en formato PDF en nuestra p gina en Internet www SunriseMedical com Ingrese a la p gina del producto espec fico para descargar el manu al o comun quese con el proveedor autorizado de Sunrise Medic...

Страница 2: ...ecyclable The separate collection and recycling of your product at the time of disposal will help conserve natural resources and ensure that it is disposed in a manner that protects the environment En...

Страница 3: ...on 18 K Swing in Swing out Footrests 18 L Elevating Legrest 18 M Angle Adjustable Centermount Footrest 18 N Dual post Fixed height standard and Dual post Height Adjustable Armrests 19 O Single post He...

Страница 4: ...to operate chair Standard Group 22 Battery Charger Off board 8 AMP Shroud Colors Red Black Blue Silver Copper Green Apple Yellow Pearl Pink Candy Purple Matte Black Midnight Blue Pearl white Digital c...

Страница 5: ...see the icons listed below to identify warnings and potential haz ards WARNING These warnings must be followed failure to do so may cause personal injury or may dam age the wheelchair ESD Electrostat...

Страница 6: ...C2 21 have been installed WARNING If there is any doubt that the specialty control input device is not immune to 20V m extra care should be taken around known sources of EMI WARNING There is no way to...

Страница 7: ...afe use by your health care professional 2 Every wheelchair is different Take the time to learn the feel of this chair before you begin riding 3 Be aware that you must develop your own methods for the...

Страница 8: ...gs axles motors or loosen fasteners J STREET USE WARNING 1 This product is not intended for street use Avoid streets whenever possible 2 Obey and follow all legal pedestrian pathways and laws that app...

Страница 9: ...oystick and cause your chair to move when you do not expect it 2 Make sure motor brakes are engaged This keeps the chair from moving when you transfer 3 Work with your health care professional to lear...

Страница 10: ...G Wheelchair lifts are used in vans buses and buildings to help you move from one level to another 1 Always turn off all power to your chair when you are on a lift If you fail to do so you may touch t...

Страница 11: ...he seat Consult with the rider s doctor nurse or therapist to find out if the rider needs such a device 4 Use positioning belts only with a rider who can cooperate Make sure the rider can easily remov...

Страница 12: ...Department if you do not receive this information P POWER SEATING SC MPC WARNING 1 Operation While driving this wheelchair in the reclined elevated or tilted position use caution Do Not attempt to op...

Страница 13: ...occur WARNING To reduce the potential of injury to vehicle occupants wheelchair mounted accessories including but not limited to IV poles trays respiratory equipment backpacks and other personal items...

Страница 14: ...rement points B Pelvic Belt Securement point C Attach WTORS to the tie down brackets in accordance with the manu facturer s instructions and SAE j2249 SECURING THE WHEELCHAIR This wheelchair is to be...

Страница 15: ...air has been tested for seating in a motor vehicle with the factory installed seating system only Ensure that the factory installed seating system is secured to the wheelchair frame before operation R...

Страница 16: ...8 ISO 10542 compliant rear secure ment straps be used to anchor the power chair during motor vehicle transport For power chairs that exceed the weight threshold mentioned above It is further rec ommen...

Страница 17: ...chair before use 4 At least once a year have a complete safety check and service of your chair performed by a supplier B CLEANING 1 Paint Finish Clean the paint finish with mild soapy water monthly P...

Страница 18: ...From the side place the pivot D into the top of the frame tube which guides the hanger into the correct alignment with the locking plate C on front frame tube b Rotate the hanger to the front until i...

Страница 19: ...c Return lever to locked position d Push arm pad until upper armpost locks firmly into place 3 Removal a Press on the release lever and remove the armrest 4 Replacing Armrest a Slide armrest back int...

Страница 20: ...Lock R BATTERY REMOVAL 1 To remove the batteries before transporting or servicing a Carefully flip back the seat see Section XI T Seat removal b Remove the shroud see Section XI E Shroud removal c Un...

Страница 21: ...according to specifications turn your wheelchair OFF immediately and contact your authorized supplier to re program oper ational settings using the RNET or VR2 operating guide If you have any problems...

Страница 22: ...e PG Drives Technology RNET control system B CONNECTORS Mating Connectors To connect the communication cables A Holding the connector housing firmly push the connector into its mate until you can no l...

Страница 23: ...The available modes are dependent on programming and the range of auxil iary output devices connected to the control system Maximum Speed Profile Indicator This is a gauge that shows the maximum speed...

Страница 24: ...Name A text string that displays the name of the currently selected profile Clock Displays the current time in a numeric format Color Joystick Speed Display Gives a proportional display of the wheelc...

Страница 25: ...d If you operate the Joystick before or just after you switch the control system on the screen will flash the joystick displaced screen You must release and center the joystick to resume normal operat...

Страница 26: ...yet left in a steady posi tion for a predetermined period of time The controller will auto matically turn off if the set time has been reached This feature is designed to protect the user batteries a...

Страница 27: ...the batteries as soon as you can bars 1 7 If the battery gauge shows just red then you should charge the batteries immediately bars 1 3 3 On Off Button E Turning the chair on or off is accomplished by...

Страница 28: ...only a certain number of times before they will fail and no longer hold a charge For answers to questions about batteries consult your Authorized Dealer 2 Use Proper Batteries Your chair operates on...

Страница 29: ...r smoke or hold an open flame near batteries 2 Protect your skin and clothes a Always wear rubber gloves and safety glasses when you handle batteries 3 Corrosion Check battery terminals often for corr...

Страница 30: ...d be set at a minimum of 60 in lbs 2 Dealer Service and Adjustment Reference materials Go to www sunrisemedical com for parts manuals instruction sheets and instructional videos that will aid in the r...

Страница 31: ...Unplug the main power connect B d Lift the batteries out of the frame using the battery strap as a lifting handle 2 Battery installation See section X Batteries for installation WARNING Batteries may...

Страница 32: ...rmrest until it starts to height adjust the armrest again c When you reach desired height remember to level the armrest using screws D and E as shown in step 2 above NOTE The cantilever armrest has ab...

Страница 33: ...osen the clamp A move the joystick and then hand tighten the clamp handle b To move the joystick to the opposite side of the chair remove the hardware B and move the clamp and joystick receiver to the...

Страница 34: ...or lowered b Using a 5mm hex key loosen the two screws F at the top of the footrest bracket and move up or down to set the correct height c Re tighten the hardware to hold the adjustment in place Q P...

Страница 35: ...ed to replace modules or adjust the seat width of the chair a Remove the 4 screws E to detach the seat pan from the modules underneath The locations of the screws may vary depending on the size of the...

Страница 36: ...ioning depending on your specific configuration Seat to floor heights and Pre tilt positioning should only be altered by a trained medical professional For the correct Pre tilt settings and seat to fl...

Страница 37: ...Position 2 2 D Position 1 1 E and position 0 default F a Using a 5mm Hex key remove the M8 flat head screws 3 on each side b Position the backrest at the desired height The top screw should be mounte...

Страница 38: ...roller a Flip up the armrest so that it is perpendicular to the floor b Loosen the thumbscrew E on the controller bracket c Slide the controller in or out of the armrest to the desired position d Tigh...

Страница 39: ...r replace covered parts This is the exclusive remedy for consequential damages F WHAT YOU MUST DO 1 Obtain an authorized supplier while this warranty is in effect prior approval for return or repair o...

Страница 40: ...per instructions in this manual to insure electromagnetic emissions are at acceptable levels TABLE 2 Immunity Test IEC 60601 test level Compliance Level Electromagnetic Environment Guidance Electrost...

Страница 41: ...E 3 Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment Guidance Portable and mobile RF communications equipment should be used no closer to any part of the product includi...

Страница 42: ...o 80 MHz d 1 2 P 80 MHz to 80 MHz d 1 2 P 800 MHz to 2 5 GHz d 1 2 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 Recommended separation distances between portable...

Страница 43: ...119832 Rev G 43 QUICKIE PULSE NOTES...

Страница 44: ...2016 Sunrise Medical US LLC 7 16 119832 Rev G Customer Service 800 333 4000 www SunriseMedical com Sunrise Medical 2842 Business Park Ave Fresno CA 93727 USA In Canada 800 263 3390...

Отзывы: