Zigbee Heating Thermostat SR-ZG9092A

Function introduction

Important: 

Read All Instructions Prior to Installation

Front side

1. Product Data

F

TIME/SHIFT button, to set 

time schedule of the 

device quickly and move 

the cursor

Function button, to 
confirm, save setting

Mode button, to switch 

operation modes and quit

Move up and move down 
buttons

LED Display

59 mm

80 mm

5

9 m

m

8

0 m

m

10 mm 10 mm

31 mm

Back side

NTC

L    L   N   N

AC Power input

Floor temp sensor

Output

Home Interface

SR-ZG9092A

Power Consumption

Ambient Temperature

Set Temperature Range

Hysteresis

Max Load

Max Current

Input Voltage

Output Voltage

Radio Frequency

Floor sensor type

Control Type

Approvals

1. NTC/10K B(25/50

)=3950 (default)

2. NTC/15K B(25/50

)=3950

3. NTC/50K B(25/50

)=3950

4. NTC/100K B(25/50

)=3950

5. NTC/12K B(25/50

)=3950

Room sensor

: adjust temperature refers to room temperature 

(factory default type).

Floor sensor

: adjust temperature refers to floor temperature.

Room+Floor sensor

: adjust temperature refers to both room 

temperature and floor temperature.

Control type means which temperature sensor the device refers to 
when it adjust temperature.

LVD

: EN 60730-1:2016;A1, EN IEC 60730-2-9:2019;A1

EMC & RF

: EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019,

EN 60730-1:2016+A1:2019, EN 60730-2-
19:2019+A1:2019+A2:2020, EN 50663:2017;ETSI EN 301 489-
1V2.2.3, ETSI EN301 489-3V2.1.1
ETSI EN300 220-1 v3.1.1., ETSI EN300 220-2 V3.2.1

CE

,

RED certificate

: 2014/53/EU

• 

All setup is performed via supported IEEE 802.15.4-based control platforms and other Zigbee3.0 compatible 

control systems. Appropriate gateway control software allows for adjustment of control mode, control type, 
schedule etc.

• 

Sensors: Air temperature

• 

THERMOSTAT MODE: OFF, HEAT, ENERGY HEAT, AWAY, DRY

• 

WARNING: Electrical power must be switched off during installation

• 

The Zigbee HVAC controller is a wireless thermostat for heating system, which complies to Zigbee 3.0 

wireless protocol standards. The thermostat has 4 operation modes which can be controlled manually and 
locally or through remote controlled through Zigbee gateway controller.

• 

Measurement range: –10°C to +60°C

• 

Accuracy: ±0.1°C 

2.4GHz

EU: AC200-240V, 50/60Hz

EU: AC200-240V

3680W @ 230V (resistive load)

16A

<2W

0°C to 40°C (during operation)

0°C to 40°C

0.5°C to 2°C (default 0.5°C)

Control Mode

AWAY, AUTO, MANUAL, DRYING, OFF

Wiring Requirement

Current 

≤ 

13A - 1.5mm² wire

Current > 13A to 16A - 2.5mm² wire

 

IP Rating

Control Pollution Degree (Method D)

Rated Impulse Voltage (Method D)

Relative Humidity

Dimensions

IP21

pollution degree 2

4kV

8% to 80%

80x80x52mm

Revised 07.02.2022

Содержание SR-ZG9092A

Страница 1: ...C RF EN IEC 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 60730 1 2016 A1 2019 EN 60730 2 19 2019 A1 2019 A2 2020 EN 50663 2017 ETSI EN 301 489 1V2 2 3 ETSI EN301 489 3V2 1 1 ETSI EN300 220 1 v3 1 1 ETS...

Страница 2: ...Warnings 4 Basic Function Introduction 4 1 Switch Operation modes Short press button on Home interface to switch operation modes the icons of Away Manual Comfort Automatic Energy Save Drying OFF modes...

Страница 3: ...lsius the step value is 1 if the unit is degree Fahrenheit the step value is 1 approximately equal to 2 7 30 24 12 00 20 18 00 16 22 30 18 Saturday Sunday 7 30 24 12 00 20 18 00 18 22 30 18 After the...

Страница 4: ...tatus 0x1004 of Thermostat Cluster 0x0201 Display Temp type Home Temp by default This parameter defines which sensor temperature will be displayed on Home page Floor Temp floor temperature external se...

Страница 5: ...x0002 of Thermostat 0x0201 is 1 3 The proprietary attribute 0x2002 Manufacturer Code 0x1224 of the cluster 0x0201 can be modified to configure whether it is away mode or at home Note Away Mode uses at...

Страница 6: ...0 Heat State Proprietary Attributes Attribute Type Description Manufacturer code 0x0003 bool read only SceneValid If true the scene identified by CurrentGroup and CurrentScene is currently active i e...

Страница 7: ...de after reset power of the device Value 0 default mode Value 1 last status before power off Default 0x1224 0x100B ENUM8 reportable DisplayAutoOffEnable 0 disable Display Auto Off function 1 enable Di...

Страница 8: ...Mask of Electrical Measurement The Alarm Server cluster can generate the following commands 0x0802 int16S reportable read only ACCurrentOverload Alarms when the current is over a certain value 0 10 16...

Страница 9: ...t temperature when energy save mode is selected The temperature schedule of auto mode energy save mode is not configured correctly 3 Current temperature is not executed when away mode is selected Chec...

Отзывы: