4.7 MONITOR SET
The function of monitor set is real time monitor of over current, over heat and freezing, on Home interface, short
press MONITOR SET to enter into monitor set interface as follows:
For configuration method and modification, please refer to Automatic Mode
(Energy Save Mode) Schedule:
4.6 Dry Mode Schedule
For example, in order to quickly dry the water on the floor of the bathroom, the device can be set to quickly heat
in a short time to dry the floor. Enter the configuration interface as follows:
Duration: set how long the dry mode lasts, can be configured through the proprietary attribute DryTime
(0x1006) of Thermostat Cluster (0x0201), the configurable range is 5-100 minutes.
After Mode: set the mode after the drying mode ends, can be configured through the proprietary attribute
ModeAfterDry (0x1007) of Thermostat Cluster (0x0201).
Remain: shows the remaining time of the drying mode
To enter into the setting interface and setting method, please refer to the 1.4
Auto Mode (Energy Save Mode) Schedule.
D means date, M means month, Y means year (2019-2099).
Start and end mean away time.
4.5 Away Mode Schedule
User can set time to leave home and time to go home according to the requirements of themselves, and set how
the device will control the temperature during this period.
1.If away mode has already been activated, the end time for away mode is valid, the device will execute Away
Mode Temperature Schedule before the end time.
2.If away mode has already been activated, the values of end time for away mode are set as 0, the device will
always execute current set temperature with no time limitation. The device will consider the mode as anti-
freeze mode, the recommended temperature setting is 4-10
℃,
and
factory
default
setting
is
6
℃.
Max floor temp (27°C by default)
This function is similar to the function of “Internal Over Heat Protection”
described in chapter 4.9. When the control type is configured as “Room+Floor
sensor”, this function will be valid:
The alarm will be triggered when the floor sensor temperature > Max floor temp,
the relay will be forced to off by the device, and the state will be reported to the
gateway. The following indication figure will prompt on the display.
Max Current (16A by default)
If current is over the set value, the relay will be forced to off by the device, and the state will be reported to the
gateway. The over current alarm function can be disabled, which can be set directly through the device. Or can
be configured through the ACAlarmsMask and ACCurrentOverload of Electrical Measurement (0X0B04), for
details please refer to the configuration value.
Note: When over current alarm is triggered, the beeper will beep, to cancel the alarm, just press and
hold button
for over 3 seconds or reset power of the device. After cancel manually, the relay will
show heating forbidden icon
within 120 seconds, but other operations are allowed.
Short press button
to select the item would like to modify, then short press
move up and move down buttons to modify value of selected item, then
short press button
to save and quit, short pressing button
only quits
without saving.
F
When
set
temperature
using
buttons
:
if
the
unit
is
degree
Celsius, the step value is 1
℃
, if the unit is degree
Fahrenheit, the step value is 1
℃ (
approximately equal to 2
℉
).
7:30,24
℃
~ 12:00,20
℃
18:00,16
℃
~ 22:30,18
℃
Saturday~Sunday
7:30,24
℃
~ 12:00,20
℃
18:00,18
℃
~ 22:30,18
℃
After the floor sensor temperature < (Max floor temp - Hysteresis), the alarm will be cancelled automatically
and the device will restore to previous operation mode.
To cancel the alarm manually, just press and hold button
for over 3 seconds, but the relay will show
heating forbidden icon
within 120 seconds and the alarm will not be triggered again, after 120 seconds
expire, the device will restore to previous operation mode and continue to detect alarm temperature.
This function can be disabled, which can be configured directly through the device,
or can be configured
through the attribute Max floor temp (0x2001) of Thermostat Cluster (0x0201), when this value is set as 0, this
function is disabled.
Hysterersis (0.5°C by default)
To prevent the undulation of sensor temperature when the sensor temperature is
approaching the set
temperature, which will cause that the controller may keep
switching on/off the relay. Here hysterersis enables the controller to control the
relay only when the sensor temperature is lower than the set temperature minus
the hysteresis value , this value can be set.
For instance, when hysterersis is set as 0.5 degree, then only when current
sensor temperature < (the set temperature - 0.5 degree), will the controller heat.
This value can also be configured through the proprietary attribute Hysterersis
(0x100A) of Thermostat Cluster (0x0201).
When
set
temperature
using
buttons
:
if
the
unit
is
degree
Celsius, the step value
is 0.5
℃
, if the unit is degree Fahrenheit, the step value is 0.5
℃ (
approximately
equal to 1
℉
).
Window Open Detect (disabled by default)
Once the device is powered on and stable, referring to the room temperature sensor, if the temperature
decreases to the threshold of this setting, the window open mark will be enabled, the relay will be forced to turn
off to save energy, then the icon will appear.
After window open mark is enabled, if the temperature increases to the threshold of this setting in 3 minutes,
the window open mark will be disabled.
Once the window open mark is enabled, it will be disabled after 10 minutes, and the device will keep current
working mode.
This value can also be configured through the proprietary attribute WindowOpenCheck (0x1009) of Thermostat
Cluster (0x0201), 0 means this function is disabled.
Note: this function will work better when the device is installed beside the window or door.
When set temperature using buttons: if the unit is degree Celsius, the step value is 0.5
℃
, if the unit is degree
Fahrenheit, the step value is 0.5
℃
(approximately equal to 1
℉
).
Short press button
to select the item would like to modify, then short
press move up and move down buttons
to modify value of selected
item, then short press button
to save and quit, short pressing button
only quits without saving.
F
4.8 TIME/DATE SET
Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as follow:
The device Time Cluster is client, if the bound device supports local time of Time Cluster, the device will
acquire local time from the bound device spontaneously under 3 situations: acquire after this device is added
to a network, acquire when the device already added to a network and power is reset, acquire every 24 hours .