5.2.9 OccupancySensing-0x0406(client)
The attributes that can be received:
Attribute
Type
Description
5.2.8 Time-0x000A(server)
The Time cluster is a general cluster for time it is based on a UTC time in seconds since 0 hrs 0 mins 0 sec on
1st January 2000. Refer to [Z2] for ZigBee specification of the time cluster.
The metering device will use this clusters as a client – provided that a suitable Time Server is available on the
network (most likely on the Gateway/concentrator)
If the device has bound TIME cluster, then the device will acquire the value of Local Time (0x0007)
spontaneously.
0x00
Room air temperature over heat, not alarm code
CmdID
Description
CmdID
Description
0x00
Alarm:
The alarm code of Electrical Measurement is 0,
Proprietary command,
Manufacturer code=0x1224
2. Remove the display unit and backplate of the device from the packaging.
3. FIRST ENSURE THE POWER IS OFF at the main circuit breaker, and then test the wires with a probe or multimeter to verify.
Insert the power and heater wires to the correct device terminals by inserting a small Phillips-head screwdriver in the slot beneath
each terminal to open. Follow the connection diagram and instructions below:
• Power wires:
connect Line & Neutral wires to L & N terminals labeled “IN”
• Heater wires:
connect Line & Neutral wires to L & N terminals labeled with “heating element” graphic
WARNING: The wire size shall be in compliance with regulations, using wire with insufficient size for big load will cause
severe temperature rising.
This device should be installed by a licensed electrician in a manner that conforms to local regulations and building codes.
Provide these instructions to the licensed electrician who is installing the device.
WARNING: Electrical power must be switched off during installation.
1. Placement of the device is of utmost importance for proper operation and must be away from sunlight and sources of direct
heat. We recommend installing the device approximately 1.5 meters above the floor.
6.Wiring diagram
5.2.7 Alarm-0x0009(Server)
Please set a valid value for ACAlarmsMask of Electrical Measurement.
The Alarm Server cluster can generate the following commands
0x0802
int16S ,
reportable
read-only
ACCurrentOverload
Alarms when the current is over a certain value, 0, 10-16, unit is A, for the
unit please refer to RMSCurrent, ACCurrentMultiplier, ACCurrent Divisor
Proprietary Attributes:
Attribute
0x0000
Type
Int8u,
reportable
Manufacturer code
0x1224
Description
OverCurrent
Over current value set by the user, range is 0, 10-16,
ACCurrentOverload will change spontaneously if this
value is modified.
0x0019
Client
Ota complies to standard Zigbee protocol.
5.4 Application Endpoint #242 –GreenPower
OTA Upgrade
Pull-oriented firmware upgrade. Searches the network for mating servers and
allows the server to control all stages of the upgrade process, including which
image to download, when to download, at what rate and when to install the
downloaded image.
int16U,
ACAlarmsMask
Specifies which configurable alarms may be generated, only
Bit1: Current Overload is set, if set=0, then ACCurrentOverload=0, over
current will not be detected
0x0800
0x0605
int16U,
read-only
ACPowerDivisor
0x01
Used together with above attributes, the real displayed power = Active Power
* ACPowerMultiplie / ACPowerDivisor
0x0000
server
Basic
0x0003
server
Identify
5.3 Application Endpoint #2–OTA
Cluster
supported
Description
int16U,
read-only
ACPowerMultiplier
0x01
0x0602
int16U,
read-only
ACCurrentMultiplier
0x0603
int16U,
read-only
ACCurrentDivisor
Used together with above attributes, the real displayed current = RMSCurrent
* ACCurrentMultiplier
/ ACCurrentDivisor
0x0604
CmdID
Description
0x00
Identify
When the device receives above commands, the characters “ident” will flash slowly at upper left corner on
Home interface.
0x01
Identify query
0x0000
bitmap8 ,
Occupancy
Bit 0 specifies the sensed occupancy as follows: 1 = occupied, 0 = unoccupied.
This flag bit will affect the Occupancy attribute of HVAC cluster, and the
operation mode.
5.2.10 Thermostat User Interface Configuration-0x0204(Server)
Attributes supported:
Attribute
Type
Description
5.2.11 Identify-0x0003(Server)
Following commands can be received:
0x0001
Enum8,
reportable
KeypadLockout
0x00 No Lockout
0x01 - 0x05 lockout
0x0000
Enum8,
reportable
TemperatureDisplayMode
0x00 Temperature in
℃
,
0x01 emperature in
℉
,