5.2.9 OccupancySensing-0x0406(client) 

The attributes that can be received:

Attribute

Type

Description

5.2.8 Time-0x000A(server) 

The Time cluster is a general cluster for time it is based on a UTC time in seconds since 0 hrs 0 mins 0 sec on 

1st  January 2000. Refer to [Z2] for ZigBee specification of the time cluster.

The metering device will use this clusters as a client – provided that a suitable Time Server is available on the 

network (most likely on the Gateway/concentrator)

If the device has bound TIME cluster, then the device will acquire the value of Local Time (0x0007) 

spontaneously.

0x00

Room air temperature over heat, not alarm code

CmdID

Description

CmdID

Description

0x00

Alarm:

The alarm code of Electrical Measurement is 0, 

Proprietary command, 

Manufacturer code=0x1224

2. Remove the display unit and backplate of the device from the packaging.
3. FIRST ENSURE THE POWER IS OFF at the main circuit breaker, and then test the wires with a probe or multimeter to verify. 
Insert the power and heater wires to the correct device terminals by inserting a small Phillips-head screwdriver in the slot beneath 
each terminal to open. Follow the connection diagram and instructions below:

• Power wires:

 connect Line & Neutral wires to L & N terminals labeled “IN”

• Heater wires:

 connect Line & Neutral wires to L & N terminals labeled with “heating element” graphic

WARNING: The wire size shall be in compliance with regulations, using wire with insufficient size for big load will cause 
severe temperature rising.  

This device should be installed by a licensed electrician in a manner that conforms to local regulations and building codes. 
Provide these instructions to the licensed electrician who is installing the device.

WARNING: Electrical power must be switched off during installation.  

1. Placement of the device is of utmost importance for proper operation and must be away from sunlight and sources of direct 
heat. We recommend installing the device approximately 1.5 meters above the floor.

6.Wiring diagram

5.2.7 Alarm-0x0009(Server)

Please set a valid value for ACAlarmsMask of Electrical Measurement.

The Alarm Server cluster can generate the following commands

0x0802

int16S ,
reportable
read-only

ACCurrentOverload

Alarms when the current is over a certain value,  0, 10-16, unit is A, for the 
unit please refer to RMSCurrent, ACCurrentMultiplier, ACCurrent Divisor

Proprietary Attributes:

Attribute

0x0000

Type

Int8u,
reportable

Manufacturer code

0x1224

Description

OverCurrent 

Over current value set by the user, range is 0, 10-16, 
ACCurrentOverload will change spontaneously if this 
value is modified. 

0x0019

Client

Ota complies to standard Zigbee protocol.

5.4 Application Endpoint #242 –GreenPower

OTA Upgrade 

Pull-oriented firmware upgrade. Searches the network for mating servers and 
allows the server to control all stages of the upgrade process, including which 
image to download, when to download, at what rate and when to install the 
downloaded image. 

int16U,

ACAlarmsMask

Specifies which configurable alarms may be generated, only
Bit1: Current Overload is set, if set=0, then ACCurrentOverload=0, over 
current will not be detected

0x0800

0x0605

int16U,
read-only

ACPowerDivisor
0x01
Used together with above attributes, the real displayed power = Active Power 
* ACPowerMultiplie / ACPowerDivisor

0x0000

server

Basic

0x0003

server

Identify

5.3 Application Endpoint #2–OTA

Cluster

supported

Description

int16U,
read-only

ACPowerMultiplier

0x01

0x0602

int16U,
read-only

ACCurrentMultiplier

0x0603

int16U,
read-only

ACCurrentDivisor

Used together with above attributes, the real displayed current = RMSCurrent 
* ACCurrentMultiplier
/ ACCurrentDivisor

0x0604

CmdID

Description

0x00

Identify

When the device receives above commands, the characters “ident” will flash slowly at upper left corner on 

Home interface. 

0x01

Identify query

0x0000

bitmap8 , 

Occupancy

Bit 0 specifies the sensed occupancy as follows: 1 = occupied, 0 = unoccupied. 
This flag bit will affect the Occupancy attribute of HVAC cluster, and the 
operation  mode.

5.2.10 Thermostat User Interface Configuration-0x0204(Server) 

Attributes supported:

Attribute

Type

Description

5.2.11 Identify-0x0003(Server)

Following commands can be received:

0x0001

Enum8,
reportable 

KeypadLockout

0x00 No Lockout
0x01 - 0x05 lockout

0x0000

Enum8,
reportable 

TemperatureDisplayMode

0x00 Temperature in 

,

0x01 emperature in 

,

Содержание SR-ZG9092A

Страница 1: ...C RF EN IEC 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 60730 1 2016 A1 2019 EN 60730 2 19 2019 A1 2019 A2 2020 EN 50663 2017 ETSI EN 301 489 1V2 2 3 ETSI EN301 489 3V2 1 1 ETSI EN300 220 1 v3 1 1 ETS...

Страница 2: ...Warnings 4 Basic Function Introduction 4 1 Switch Operation modes Short press button on Home interface to switch operation modes the icons of Away Manual Comfort Automatic Energy Save Drying OFF modes...

Страница 3: ...lsius the step value is 1 if the unit is degree Fahrenheit the step value is 1 approximately equal to 2 7 30 24 12 00 20 18 00 16 22 30 18 Saturday Sunday 7 30 24 12 00 20 18 00 18 22 30 18 After the...

Страница 4: ...tatus 0x1004 of Thermostat Cluster 0x0201 Display Temp type Home Temp by default This parameter defines which sensor temperature will be displayed on Home page Floor Temp floor temperature external se...

Страница 5: ...x0002 of Thermostat 0x0201 is 1 3 The proprietary attribute 0x2002 Manufacturer Code 0x1224 of the cluster 0x0201 can be modified to configure whether it is away mode or at home Note Away Mode uses at...

Страница 6: ...0 Heat State Proprietary Attributes Attribute Type Description Manufacturer code 0x0003 bool read only SceneValid If true the scene identified by CurrentGroup and CurrentScene is currently active i e...

Страница 7: ...de after reset power of the device Value 0 default mode Value 1 last status before power off Default 0x1224 0x100B ENUM8 reportable DisplayAutoOffEnable 0 disable Display Auto Off function 1 enable Di...

Страница 8: ...Mask of Electrical Measurement The Alarm Server cluster can generate the following commands 0x0802 int16S reportable read only ACCurrentOverload Alarms when the current is over a certain value 0 10 16...

Страница 9: ...t temperature when energy save mode is selected The temperature schedule of auto mode energy save mode is not configured correctly 3 Current temperature is not executed when away mode is selected Chec...

Отзывы: