0x1007
ENUM8
reportable
ModeAfterDry
The mode after Dry Mode:
Value=0 : OFF
Value=1 : Manual mode
Value=2 : Auto mode –schedule (default)
Value=3 : Away mode
0x1224
0x1008
ENUM8
reportable
TemperatureDisplay :
Value=0 : Room Temp (Default)
Value=1 : Floor Temp
0x1224
0x1009
INT8U
reportable
WindowOpenCheck
The threshold to detect open window, range is 0.3-8, unit is
0.5ºC,
0 means disabled, default is 0
0x1224
0x100A
INT8U
reportable
Hysterersis
Hysterersis setting, range is 5-50, unit is 0.1ºC, default value
is 5
0x1224
0x2001
INT8U,
reportable
Max floor temp
Floor temperature over heating threshold, range is 0-35, unit
is 1ºC, 0 means this function is disabled, default value is 27.
0x1224
5.2.5 Simple Meter-0x0702 (Server)
Attributes supported:
0x0000
bitmap32 ,
read-only
MeasurementType
Indicates the physical entities that this devices is able to measure. Supports
only bit0: Active measurement (AC)
0x0505
int16U ,
read-only,
reportable
RMSVoltage
Single phase valid voltage, unit is V
0x0508
int16U ,
reportable,
read-only
RMSCurrent
Single phase valid current, unit is A
0x050B
int16S ,
reportable
read-only
ActivePower
Single phase valid power, unit is W
0x0600
int16U,
read-only
ACVoltageMultiplier
0x0601
int16U,
read-only
ACVoltageDivisor
Used together with above attributes, the real displayed voltage =
RMSVoltage* ACVoltageMultiplier
/ ACVoltageDivisor
0x1006
INT8U
reportable
DryTime
The duration of Dry Mode, range is 5-100, unit is min.
Default value is 5.
0x1224
0x1005
INT8S,
reportable
FloorSenserCalibration
The temp compensation for the external (floor) sensor, range
is -30-30, unit is 0.1°C. default value 0
0x1224
0x1004
ENUM8
reportable
PowerUpStatus
The mode after reset power of the device:
Value=0 : default mode
Value=1 : last status before power off (Default)
0x1224
0x100B
ENUM8
reportable
DisplayAutoOffEnable
0, disable Display Auto Off function
1, enable Display Auto Off function
0x1224
5.2.6 Electrical Measurement-0x0b04(Server)
Attributes supported:
Attribute
Type
Description
0x0306
bitmap8,
read-only
MeteringDeviceType
Metering data type, this is always Electric Metering (0x00)
0x0302
Int24U,
read-only
Divisor
0x0303
map8 ,
read-only
SummationFormatting
The decimal point on the left and right sides of the data, this is always 0x00
ENUM8
reportable
ControlType
The referring sensor for heat control:
Value=0 : Room sensor(Default)
Value=1 : floor sensor
Value=2 : Room+floor sensor
0x1002
ENUM8
reportable
FloorSenserType
Select external (Floor) sensor type:
Value=5 : NTC 12K/25
Value=4 : NTC 100K/25
Value=3 : NTC 50K/25
Value=2 : NTC 15K/25
Value=1 : NTC 10K/25 (Default)
0x1224
0x1003
0x1224
0x0301
Int24U,
read-only
Multiplier
0x0000
unsigned48 ,
read-only,
reportable
CurrentSummationDelivered
Indicates the current amount of electrical energy delivered to the load.
0x0200
bitmap8 ,
read-only
Status
Flags indicating current device status, always is 0x00
0x0300
enum8 ,
read-only
UnitOfMeasure
The unit of metering data, this is always kWh(0x00)
Attribute
Type
Description
ButtonVibrationLevel
Key beep volume & vibration level:
Value=0 : off(default)
Value=1 : Low Level
Value=2 : High Level
0x1000
ENUM8,
reportable
OperateDisplayLcdBrightnesss
OLED brightness when operate the buttons:
Value=0 : Low Level
Value=1 : Mid Level(default)
Value=2 : High Level
0x1224
0x1001
ENUM8
reportable
0x1224
Command supported:
Command
Description
0x0000
Setpoint Raise/Lower
Increase or decrease the set temperature according to current mode, unit is
0.1ºC
0x2002
ENUM8
reportable
Away Mode Set:
Value=0: not away (default)
Value=1: away
0x1224