Содержание SCP series

Страница 1: ......

Страница 2: ...ring 3 5 Figure 2 Control Panel Figure 3 Dip Switch Settings Controller Settings 3 6 Auxiliary Control Circuits 3 7 Remote Switch Output Power Limit Circuit Low Power Shut Down Circuit Low Water Shut...

Страница 3: ...es controller or product damage and or personal injury may result Do not exceed the voltage rating of the controller Do not splash water on the controller especially when the cover is open Mount the c...

Страница 4: ...rless DC motors No other applications or DC power sources are recommended or warranted unless written approval is provided by the SunPumps factory 3 0 Installation and Operation The following sections...

Страница 5: ...he solar modules as specified by the National Electric Code Wire sized too small will cause a decreased output from the pump Keep the distance from the solar modules to the pump as short as possible R...

Страница 6: ...valves are open and strainer pot temperature is cool to the touch then with extreme caution you can open the strainer lid Do not open the strainer pot lid while the pump in in operation Strainer Clea...

Страница 7: ...ble or call your SunPumps dealer for assistance Wire gauge being too small will cause excessive voltage losses to the motor and will reduce the flow rate of the pump All other system equipment should...

Страница 8: ...Figure 2 Controller Wiring Diagram...

Страница 9: ...9 Connect the DC source supply positive the red conductor to one of the controller terminals labeled Positive on the Solar Array Input NOTE The power should be connected to a disconnect and it should...

Страница 10: ...ic Turns pump off when terminals connect OFF 2 ON Low Water Cutoff Logic Turns pump on when terminals connect OFF 3 ON 10 Minute Delay Increases turn on delay to 10 minutes OFF 4 ON 30 Minute Delay In...

Страница 11: ...tor speed control is for adjusting the flow rate of the pump There is also the low water cutoff low power shut down and over current protection circuits See each corresponding detailed description bel...

Страница 12: ...troller program This timeout applies to remote switch and low water cutoff Low Power Shut Down Sensorless Low Water Cut Off Circuit LPLW The Low Power Shut Down Low Water Cut Off Circuit LPLW turns th...

Страница 13: ...atch the flow rate of the pump to the production of the well 1 With the system installed and controller properly configured allow the pump to run at full power at mid day until the pump starts surging...

Страница 14: ...lay Screens NOTE Dip switch 7 will freeze the display on the current screen If the system is powered up with switch 7 on the display will only show the SUNPUMPS INC screen Turn off switch 7 to unfreez...

Страница 15: ...ote circuit or low water cutoff circuit is preventing the controller from running the pump Set the 1 and 2 dip switches to off and disconnect the remote switch and low water cutoff If the pump starts...

Страница 16: ...complete series string PUMP IS RUNNING BUT THE OUTPUT IS LOW 1 Make sure you have full sun light at midday that there are no clouds and no shadows on any part of the array Then verify power coming ou...

Страница 17: ...heet is a must Pump Model Number ____________________ Pump Serial Number ____________________ Motor Serial Number ____________________ Controller Model Number ____________________ Software Version ___...