12X
2X
2X
F1000C / F1500C / F2000C
F600C & F700C
PATENT
PENDING
FILTER
SYSTEM
2X
DISTRIBUTED BY: POLYGROUP LIMITED (MCO)
Avenida Xian Xing Hai, Centro Golden Dragon, 11 Andar M, Macau
Customer Service: (888) 919-0070 • www.polygroup.com
SFS TYPE SWIMMING POOL FILTER SYSTEM OWNER’S MANUAL
FOR ABOVE GROUND QUICK SET® SWIMMING POOLS
IMPORTANT SAFETY INSTRUCTIONS
PRELIMINARY STEPS
POWER FILTER
FILTER CARTRIDGE CLEANING
POOL MAINTENANCE
POOL WATER CARE
TROUBLE SHOOTING GUIDE
DISASSEMBLY AND STORAGE
NOTES
2
2
2
5
6
7
8
8
9
WITH GFCI - 2012
084-120839
2
2
IMPORTANT SAFETY INSTRUCTIONS
PRELIMINARY STEPS
POWER FILTER
When installing and using this electrical equipment, basic safety precautions should always be followed,
including the following:
1.
READ AND FOLLOW ALL INSTRUCTIONS
2.
WARNING -
To reduce the risk of injury, do not permit children to use this product unless they are
closely supervised at all times by an adult who is capable of assisting a child in distress.
3.
WARNING -
Risk of electrical shock. Connect only to a grounding type receptacle. This product is
provided with a ground-fault circuit-interrupter. If replacement of the plug or cord is needed, use only
identical replacement parts.
4.
WARNING -
To reduce the risk of electrical shock, replace damaged cord (with pump body)
immediately. NEVER bury cord. Locate cord to eliminate abuse or contact from lawn mowers, hedge
trimmers, and other equipment. NEVER use an extension cord to connect unit to electric supply;
provide a properly located outlet.
5.
CAUTION -
The power filter is for use with storable pools only. DO NOT use with permanently
installed pools. A storable pool is constructed so that it may be readily disassembled for storage and
reassembled to its original integrity. A permanently installed pool is constructed in or on the ground or
in a building so that it cannot be readily disassembled for storage.
6. The unit is provided with a ground-fault circuit-interrupter (GFCI). To test the GFCI, push the test button.
The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to
operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test
button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not
se this pump. Disconnect the pump and have the problem corrected by a qualified service
representative before using.
7.
SAVE THESE INSTRUCTIONS.
1. READ ALL INSTRUCTIONS CAREFULLY and get a thorough understanding of what is required to
assemble your Type SFS Power Filter.
2. Before you begin to assemble the pool, identify, count, and check all parts needed for assembly. Refer to
the“PARTS LIST AND ACCESSORIES”, Page #9, under the quantity column for your size pool.
3. It is recommended that you have some PETROLEUM JELLY on hand for lubricating the gaskets.
1. Installer shall follow written instructions provided for operation of the circulation systems.
2. All electrical components shall be installed in accordance with Article 680 of the National Electrical
Code (NEC) “Swimming Pools, Fountains and Similar Installations” or its latest approved edition.
3. The Filter Cartridge (9) 3-3/4” will hold as many as 2 of the 1” diameter chlorine tablets and the 8” will
hold as many as 6 of the 1” diameter chlorine tablets. Check your chlorine levels to determine the
proper number of chlorine tablets to add. The filter cartridge will automatically dispense chlorine into
the pool as the pump runs. You must have the type of Filter Cartridge (9) with a central core mesh
divider (See page 3) to use the chlorine dispenser. DO NOT use this to dispense powdered chlo-
rine, shock treatment or any other type of chemicals as damage to the pump, filter cartridge, and
pool will occur.
4. These Skimmer Filter Systems are manufactured by Polygroup and ETL control number 4000608 -
double insulated and grounded - 115 V.A.C. - 60 Hz. (Unit must have a
minimum of 105 V.A.C. to start and run properly.) The units’ wattage and capacity is as follows:
IMPORTANT NOTES:
SFS600 Filter System with F600C Pump
46 watts
0.8 amps
580 G.P.H.
780 G.P.H.
780 G.P.H.
1075 G.P.H.
1500 G.P.H.
2000 G.P.H.
1.1 amps
1.1 amps
2.2 amps
2.0 amps
2.2 amps
57 watts
57 watts
80 watts
120 watts
210 watts
SFS600 Filter System with F700C Pump
SFS1000 Filter System with F700C Pump
SFS1000 Filter System with F1000C Pump
SFS1000 Filter System with F1500C Pump
SFS2000 Filter System with F2000C Pump
LIMITED WARRANTY
Polygroup Limited (Macao Commercial Offshore), (hereinafter “Polygroup”) warrants to the original purchaser only,
the SFS type Electric Filter Pump against defects in material and workmanship for 180 days from the date of
purchase. Original Purchaser must retain proof of such purchase in the form of an original store sales receipt and
must produce such upon request by Polygroup or its designated agents. Warranty claims cannot be processed
without a valid proof of purchase.
This Limited Warranty applies only to the original purchaser of the product and is limited solely to the repair or
replacement of the product, to be decided in Polygroup’s sole discretion. Consequential damages, including claims
for loss of water, pool chemicals, damage, or labor are not covered under this Limited Warranty.
This Warranty will be declared invalid should the Purchaser modify or repair the product themselves or by
unauthorized persons; use non-Polygroup parts or accessories with the product; use the product in contravention
of the Manufacturers Instructions; use improper voltage; abuse the product in any way; or through accident or
negligence. Normal wear-and-tear is not covered under this Warranty, nor are acts of God outside the control of
Polygroup.
IN NO EVENT SHALL POLYGROUP, THEIR AUTHORIZED AGENTS, RELATED ENTITIES, OR EMPLOYEES BE LIABLE TO THE
BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES. Some states or countries, or others
jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
Should you encounter a problem with your Polygroup Product, please do not return the product to the place or
purchase. All Warranty claims must be made directly to Polygroup. Prior to contacting Customer Service, please
first review the Troubleshooting Guide in the Installation Manual, or review the FAQ at www.polygroup.com . If you
are still unable to correct the problem, please contact Polygroup customer service at (888) 919-0070. Have the
product type and your purchase receipt ready. Our Customer Service Representative will assist you in resolving the
problem. You may be asked to return all or part of the product for inspection and/or repair. Do not return any
product to Polygroup without a Return Authorization number.