Layout for rail mounting

 

 

 

Note: 

 

Please refer to appendix regarding Kliplok 406-like and Kliplok 700-like roof sheeting mounting. 

 

Please contact the local distributors if you are not sure whether your color steel roofing is suit for SMD 

Series or you have any question about this installation method. 

 

Please contact the local distributors if you want to remove SMD Series from your color steel roofing. 

 

Do not install using quick bonding method when rain is present 

 

Do not install using quick bonding method when wind speeds greater than 10m/s are present at the 

site within 24 hours 

 

Roof and ambient temperature during installation shall be between -15

 and 45

℃ 

during application 

 

If installation method is strictly adhered to, Sunman will provide a 10 year warranty for the Tonsan 1527 

 

Framed Installation 

For SMA Series   

SMAxxxM-6X12DW, SMAxxxM-6X10DW, SMAxxxM-4X12DW, SMAxxxM-4X09DW 

SMAxxxM-6X12UW, SMAxxxM-6X10UW, SMAxxxM-4X12UW, SMAxxxM-4X09UW 

 

Clamps  can  be  used  for  the  connection  of  SMA  series  components  and  support  system.  The 

installation must be completed according to the following example, otherwise the warranty will be 

invalid. 

 

Horizontal installation of SMA series components. 

Содержание eArc SMA160M-4X09DW

Страница 1: ...eArc PV System Installation Manual...

Страница 2: ...his guide Features Benefits Notices General safety Handling safety Installation safety Fire safety Production Identification Mechanical Installation Grounding Electrical installation Disclaimer of lia...

Страница 3: ...tion For any questions please contact SUNMAN s Customer Service Department or our local representatives for more detailed information Installers should follow all safety precautions described in this...

Страница 4: ...w sunman energy com version 2019A page 2 18 TM Features Benefits Flexible layouts eArcTM PV system can be installed at any shape roofs which has integrated appearance with buildings Maximization insta...

Страница 5: ...s required for eArcTM PV System PV arrays Copyright and Trademark Information Copyright 2019 by Sunman Zhenjiang Company Limited All rights reserved eArc and the SUNMAN logo are trademarks of Sunman Z...

Страница 6: ...d mounted mounted on rooftops vehicles or boats The proper design of support structures lies within the responsibility of the system designers and installers Do not use mirrors or other magnifiers to...

Страница 7: ...nections or unplug connectors while the circuit is under load Contact with electrically charged parts of the panels such as terminals can result in burns sparks and lethal shock whether or not the pan...

Страница 8: ...ated current rated voltage open circuit voltage short circuit current all as measured under standard test conditions weight dimensions etc the maximum system voltage is 1000 volts Barcode each individ...

Страница 9: ...ing eArc with a tilt angle of at least 10 degrees making it easier for dust to be washed off by rain Always keep the back sheet of the panel free from foreign objects plants and vegetation or structur...

Страница 10: ...steel roof sheeting Any other roof sheeting requires consolation with Sunman or its local importer b Size of color steel roofing c Preparation of bonding material Prepare silicone nozzle by cutting a...

Страница 11: ...n to clean cloth Wiping down the roof apply to the adhesion area Reapply until clean Leave to dry e Install chemical bonding material Apply the silicon with the nozzle perpendicular to the roof The le...

Страница 12: ...manual are subject to change without notice www sunman energy com version 2019A page 10 18 TM f Layout of SMD Series Layout For SMD Series SMDxxxM 6X12DW SMDxxxM 6X12UW SMDxxxM 6X10DW SMDxxxM 6X10UW...

Страница 13: ...o not install using quick bonding method when rain is present Do not install using quick bonding method when wind speeds greater than 10m s are present at the site within 24 hours Roof and ambient tem...

Страница 14: ...be properly secured to their supports so that they can withstand the pressure of the load including the rise and pressure of the wind It is the responsibility of the installer to ensure that the moun...

Страница 15: ...always grounded SUNMAN recommends always refer to local state and national code requirements for PV module grounding SUNMAN highly recommends negative grounding if it s allowed by local authorities W...

Страница 16: ...ding is achieved by bonding all conductors on the module frame and metal mounting structures continuously with a suitable grounding conductor Third party grounding solutions are acceptable These solut...

Страница 17: ...ort circuit current The recommended cable is PV wire temperature rating is 90 with a cross section of at least 2 5mm Please refer to local regulations to determine the system wires size type and tempe...

Страница 18: ...1 9 52 1662mm X 1019mm X 5 6mm 5 5kg 20A 20 SMD290M 6X10DW 290 32 6 8 90 39 9 9 43 1662mm X 1019mm X 5 6mm 5 5kg SMD285M 6X10DW 285 32 4 8 80 39 7 9 34 1662mm X 1019mm X 5 6mm 5 5kg SMD280M 6X10DW 280...

Страница 19: ...m X 995mm X 35mm 7 6kg 20A 20 SMA290M 6X10DW 290 32 6 8 90 39 9 9 43 1638mm X 995mm X 35mm 7 6kg SMA285M 6X10DW 285 32 4 8 80 39 7 9 34 1638mm X 995mm X 35mm 7 6kg SMA280M 6X10DW 280 32 2 8 70 39 5 9...

Страница 20: ...X 665mm X 35mm 6 4kg SMA225M 4X12UW 225 25 5 8 83 31 3 9 36 1983mm X 665mm X 35mm 6 4kg SMA220M 4X12UW 220 25 2 8 74 31 1 9 27 1983mm X 665mm X 35mm 6 4kg SMA215M 4X12UW 215 24 9 8 64 30 9 9 18 1983mm...

Страница 21: ......

Страница 22: ......

Отзывы: