© 2019 Sunman (Zhenjiang) Co., Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
www.sunman-energy.com
version 2019A page 9 / 18
TM
•
If using Tonsan 1527, clean the roof with isopropyl alcohol and wait to dry.
•
If using Sika SG-20, apply the Sika Aktivator-205 on to clean cloth. Wiping down the roof, apply to the
adhesion area. Reapply until clean. Leave to dry.
e.
Install chemical bonding material
•
Apply the silicon with the nozzle perpendicular to the roof. The length of the chemical bonding material
shall not be less than the number corresponding to L in the following table.
eArc
SMDxxxM-4X12DW,
SMDxxxM-4X12UW,
SMDxxxM-4X09DW
SMDxxxM-4X09UW
SMDxxxM-6X12DW,
SMDxxxM-6X12UW,
SMDxxxM-6X10DW,
SMDxxxM-6X10UW
L
665mm
995mm
•
Please see below for proper bead application