background image

 

 

PPC-F08B/F10B-BT Panel PC 

Page I 

User Manual 

PPC-F08B/F10B-BT Panel PC 

MODEL: 

PPC-F08B/F10B-BT 

Industrial Panel PC with Intel® Celeron® Processor J1900, 

Touchscreen, Dual PCIe Mini, USB 3.0,   

RS-232/422/485, Dual PCIe GbE, 9 V ~ 30 V DC-in 

IP 65 Compliant Front Panel and RoHS Compliant 

Rev. 1.03 – December 13, 2017 

Содержание F10B-BT

Страница 1: ...08B F10B BT Panel PC MODEL PPC F08B F10B BT Industrial Panel PC with Intel Celeron Processor J1900 Touchscreen Dual PCIe Mini USB 3 0 RS 232 422 485 Dual PCIe GbE 9 V 30 V DC in IP 65 Compliant Front...

Страница 2: ...Section 1 9 Specifications Updated Section 2 3 Optional Items Updated Section 3 11 2 Panel Mounting August 8 2016 1 02 Added Section 3 8 Wireless LAN Module Installation Optional June 27 2016 1 01 Add...

Страница 3: ...es arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All...

Страница 4: ...ION Cautionary messages should be heeded to help reduce the chance of losing data or damaging the product NOTE These messages inform the reader of essential but non critical information These messages...

Страница 5: ...NG LIST 13 2 3 OPTIONAL ITEMS 14 3 INSTALLATION 16 3 1 ANTI STATIC PRECAUTIONS 17 3 2 INSTALLATION PRECAUTIONS 17 3 3 PREINSTALLED COMPONENTS 18 3 4 INSTALLATION AND CONFIGURATION STEPS 18 3 5 REMOVIN...

Страница 6: ...SYSTEM 41 3 13 RESET THE SYSTEM 42 3 14 CLEAR CMOS 42 3 15 OS INSTALLATION 43 3 16 DRIVER INSTALLATION 44 3 16 1 Keypad AP 45 4 SYSTEM MAINTENANCE 46 4 1 SYSTEM MAINTENANCE OVERVIEW 47 4 2 SO DIMM REP...

Страница 7: ...TORS 84 6 2 INTERNAL PERIPHERAL CONNECTORS 85 6 2 1 Battery Connector BAT1 86 6 2 2 Digital I O Connector DIO1 86 6 2 3 Inverter Connector INV_CN1 87 6 2 4 LVDS Connector LVDS1 87 6 2 5 MCU Connector...

Страница 8: ...Voltage Selection Jumper J_BL1 96 6 4 2 Inverter Power Selection Jumper JP2 96 6 4 3 LVDS Panel Voltage Selection Jumper J_VLVDS1 96 6 4 4 Panel PWM Power Selection Jumper J_ADJ1 97 A REGULATORY COMP...

Страница 9: ...ion Screws 22 Figure 3 6 HDD Retention Screws 22 Figure 3 7 PPC F10B BT HDD Installation 23 Figure 3 8 Knockouts on Top Panel for Wireless Antennas 23 Figure 3 9 PCIe Mini Slot Location 24 Figure 3 10...

Страница 10: ...Figure 3 28 Install into a Rack Cabinet 38 Figure 3 29 Arm Mounting ARM 11 RS 40 Figure 3 30 Stand Mounting Stand B08 41 Figure 3 31 Powering On the System 41 Figure 3 32 Reset Button Location 42 Figu...

Страница 11: ...S1 Pinouts 87 Table 6 6 MCU Connector MCU_CN1 Pinouts 88 Table 6 7 Microphone Connector DMIC1 Pinouts 88 Table 6 8 PCIe Mini Connector M_PCIE1 Pinouts 89 Table 6 9 PCIe Mini Connector M_PCIE2 Pinouts...

Страница 12: ...erial Port COM2 Pinouts 95 Table 6 26 USB 3 0 Connectors USB_CON1 Pinouts 95 Table 6 27 Preconfigured Jumpers 96 Table 6 28 Backlight Voltage Selection Jumper J_BL1 Settings 96 Table 6 29 Inverter Pow...

Страница 13: ...7 RTC Wake Settings 64 BIOS Menu 8 Serial Port Console Redirection 65 BIOS Menu 9 iEi Feature 66 BIOS Menu 10 CPU Configuration 67 BIOS Menu 11 IDE Configuration 69 BIOS Menu 12 USB Configuration 70 B...

Страница 14: ......

Страница 15: ...PPC F08B F10B BT Panel PC Page 1 1 Introduction Chapter 1...

Страница 16: ...l environments and enriches aesthetic experience at the same time The Intel Celeron processor J1900 is a SoC System on Chip that ensures optimal memory graphics and peripheral I O support The major ex...

Страница 17: ...o Table 1 1 Model Variations 1 3 Features Some of the features of the PPC F08B F10B BT panel PC include Robust aluminum IP 65 compliant front bezel Aesthetic ultra thin bezel for seamless panel mount...

Страница 18: ...BT Figure 1 2 is a flat panel LCD screen surrounded by an aluminum frame Figure 1 2 Front View 1 5 Rear Panel The rear panel has a fan vent several VESA mounting holes and retention screws The VESA m...

Страница 19: ...PPC F08B F10B BT Panel PC Page 5 Figure 1 4 PPC F10B BT Rear View 1 6 Bottom Panel The bottom panel has the following interfaces Figure 1 5 PPC F08B BT Bottom Panel...

Страница 20: ...the user must enter the Boot BIOS menu first and choose which operating system will be installed Otherwise the USB 2 0 and USB 3 0 ports cannot be used for OS installation Please refer to Section 5 6...

Страница 21: ...PPC F08B F10B BT Panel PC Page 7 1 8 Dimensions 1 8 1 PPC F08B BT Dimensions Figure 1 8 PPC F08B BT Dimensions mm...

Страница 22: ...PPC F08B F10B BT Panel PC Page 8 1 8 2 PPC F10B BT Dimensions Figure 1 9 PPC F10B BT Dimensions mm...

Страница 23: ...core Intel Celeron processor J1900 Memory Preinstalled one 2 GB DDR3L SO DIMM system max 8 GB Touchscreen 5 wire resistive type Surface hardness 3H Touch controller PenMount DMC9000 Ethernet 2 x Realt...

Страница 24: ...2 485 DB 9 1 x Audio line out jack 1 x Power jack 1 x Power button 1 x Reset button 1 x AT ATX switch Power Input 9 V 30 V DC Power Adapter 36W power adapter Input 90V 264V AC 50 60Hz Output 12V DC Po...

Страница 25: ...PPC F08B F10B BT Panel PC Page 11 2 Unpacking Chapter 2...

Страница 26: ...e installation process Step 1 Use box cutters a knife or a sharp pair of scissors that seals the top side of the external second box Step 2 Open the external second box Step 3 Use box cutters a knife...

Страница 27: ...age 1 PPC F08B F10B BT panel PC 1 Power adapter 36 W 12 V DC input 1 Power cord part number varies by regions 1 RJ 45 to DB 9 COM port cable 4 Screws for VESA mounting 2 Screws for mSATA module instal...

Страница 28: ...iately 2 3 Optional Items The following are optional components which may be separately purchased Item and Part Number Image Arm P N ARM 11 RS Panel mount kit for PPC F08B BT P N FPK 07 R10 Panel moun...

Страница 29: ...PPC F08B F10B BT Panel PC Page 15 Item and Part Number Image VESA 75 wall mount kit P N AFLWK 12 Wi Fi kit P N EMB WIFI KIT01 R20 Table 2 2 Optional Items...

Страница 30: ...PPC F08B F10B BT Panel PC Page 16 3 Installation Chapter 3...

Страница 31: ...help to prevent ESD from damaging the board Self grounding Before handling the board touch any grounded conducting material During the time the board is handled frequently touch any conducting materi...

Страница 32: ...n anti static wristband 3 3 Preinstalled Components The following components are all preinstalled Motherboard TFT LCD Touchscreen DDR3L memory module Preinstalled OEM customizations may include the fo...

Страница 33: ...he back cover remove the back cover retention screws on the back cover Lift the cover up to remove The following diagrams show the back cover screw locations of each model Figure 3 1 PPC F08B BT Back...

Страница 34: ...e PCIe Mini card slot Remove the preinstalled retention screw on the screw pillar of the PCIe Mini card slot as shown in Figure 3 3 Figure 3 3 mSATA Module Slot Location Step 3 Line up the notch on th...

Страница 35: ...ly The PPC F10B BT has a 2 5 HDD bay inside the chassis To install an HDD into the PPC F10B BT please follow the steps below Step 1 Remove the back cover See Section 3 5 Step 2 Remove the HDD bracket...

Страница 36: ...to the bracket and secure the hard drive to the bracket with four retention screws Figure 3 6 Figure 3 6 HDD Retention Screws Step 4 Connect the SATA cable and the SATA power cable to the rear of the...

Страница 37: ...eless LAN Module Installation Optional To install the optional wireless LAN WLAN module please follow the steps below Step 1 Remove the back cover See Section 3 5 Step 2 Remove the two knockouts for a...

Страница 38: ...the PCIe Mini slot Figure 3 9 Figure 3 9 PCIe Mini Slot Location Step 4 Line up the notch on the WLAN module with the notch on the slot Slide the WLAN module into the slot at an angle of about 20 Fig...

Страница 39: ...PC Page 25 Step 5 Secure the WLAN module with two retention screws Figure 3 11 Securing WLAN Module Step 6 Connect the two RF cables to the antenna connectors on the WLAN module Figure 3 12 Figure 3 1...

Страница 40: ...and tightening it with nut Step 10 Install the external antenna Figure 3 13 Securing SMA Connector and External Antenna Installation 3 9 Serial Port Configuration and Connection The PPC F08B F10B BT s...

Страница 41: ...communication protocol used by the DB 9 serial communication port as RS 232 RS 422 or RS 485 Please note that when the DB 9 serial port is set to RS 422 485 the DB 9 port becomes COM3 The RS 232 422...

Страница 42: ...onfigures pin 9 on the DB 9 serial port Pin 9 on the COM2 DB 9 connector can be set as the ring RI signal 5 V or 12 V The jumper selection options are shown in Table 3 3 JP5 Description Short 1 2 COM2...

Страница 43: ...ption Pin No Description 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI Table 3 4 RS 232 Serial Port COM1 Pinouts 3 9 5 RS 232 Serial Port Connection The RS 232 port COM1 is a RJ 45 serial devic...

Страница 44: ...s on the port while the connectors for the serial cables don t Step 2 Insert the RJ 45 to D sub 9 cable Step 3 Insert the serial connector Insert the D sub 9 connector of a serial device into the D su...

Страница 45: ...its a production line to control multiple panel PCs from a central management center and other applications including ATM Self service kiosk Plant environment monitoring system Factory automation plat...

Страница 46: ...The methods of mounting the PPC F08B F10B BT are Wall mounting Panel mounting Rack mounting Arm mounting Stand mounting The mounting methods are described in the following sections 3 11 1 Wall Mountin...

Страница 47: ...PC F08B F10B BT Step 3 Hook the PPC F08B F10B BT into the mounting holes on the wall mounting kit Figure 3 20 Hook Onto Wall Mounting Kit WARNING Please use the M4 screws provided in the package for t...

Страница 48: ...ned the PPC F08B F10B BT should not be able to move S t e p 0 Figure 3 21 Tighten Retention Screw 3 11 2 Panel Mounting To mount the PPC F08B F10B BT panel PC into a panel please follow the steps belo...

Страница 49: ...that corresponds to the rear panel dimensions of the PPC F08B F10B BT The recommended cutout sizes are shown below Figure 3 23 and Figure 3 24 Figure 3 23 PPC F08B BT Panel Cutout Dimensions Figure 3...

Страница 50: ...ormed holes along the edges of the PPC F08B F10B BT behind the aluminum frame Figure 3 25 Step 6 Tighten the screws that pass through the mounting clamps until the plastic caps at the front of all the...

Страница 51: ...B BT flat panel PC and the rack cabinet into which the PPC F08B F10B BT is installed Step 1 PPC F10B BT Only Install two mounting brackets onto the rear panel of the PPC F10B BT Figure 3 22 Step 2 Sli...

Страница 52: ...ps until the plastic caps at the front of all the screws are firmly secured to the bracket Figure 3 27 Figure 3 27 Secure the Rack Cabinet Bracket Step 5 Slide the PPC F08B F10B BT with the attached r...

Страница 53: ...nstallation documentation that came with the mounting arm NOTE When purchasing the arm please ensure that it is VESA compliant and that the arm has a 75 mm or 100 mm interface pad If the mounting arm...

Страница 54: ...Step 1 Locate the screw holes on the rear of the PPC F08B F10B BT This is where the bracket will be attached The mounting screw holes of the PPC F08B F10B BT panel PC are shown in Figure 1 3 and Figur...

Страница 55: ...Step 1 Connect the power cord to the power adapter Connect the other end of the power cord to a power source Step 2 Connect the power adapter to the power connector of the PPC F08B F10B BT Step 3 Loc...

Страница 56: ...3 14 Clear CMOS If the PPC F08B F10B BT fails to boot due to improper BIOS settings the clear CMOS jumper clears the CMOS data and resets the system BIOS information To do this push the clear CMOS but...

Страница 57: ...ing the operating system the user must enter the Boot BIOS menu first and choose which operating system will be installed Otherwise the USB 2 0 and USB 3 0 ports cannot be used for OS installation Ple...

Страница 58: ...F08B F10B BT are on the utility CD that came with the system The utility CD contains drivers for Windows 7 and Windows 8 operating systems Please select the corresponding drivers for the system The f...

Страница 59: ...eypad AP Keypad AP is an OSD control tool developed by IEI After the installation the Keypad AP can be accessed by clicking the icon on the notification area It allows users to control screen brightne...

Страница 60: ...PPC F08B F10B BT Panel PC Page 46 Chapter 4 4 System Maintenance...

Страница 61: ...m damage To preserve the working integrity of the PPC F08B F10B BT the system must be properly maintained If internal components need replacement the proper maintenance procedures must be followed to...

Страница 62: ...ow the steps below Step 1 Remove the back cover by removing the retention screws See Section 3 5 Step 2 Locate the SO DIMM Figure 4 1 Figure 4 1 SO DIMM Location Step 3 Release the arms on the SO DIMM...

Страница 63: ...PPC F08B F10B BT Panel PC Page 49 Figure 4 2 SO DIMM Installation Step 6 Reinstall the back cover Step 0...

Страница 64: ...PPC F08B F10B BT Panel PC Page 50 5 BIOS Setup Chapter 5...

Страница 65: ...1 Press the DELETE or F2 key as soon as the system is turned on or 2 Press the DELETE or F2 key when the Press DELETE or F2 to enter SETUP message appears on the screen 0 If the message disappears be...

Страница 66: ...F2 Load previous values F3 Load optimized defaults F4 Save changes and Exit BIOS Table 5 1 BIOS Navigation Keys 5 1 3 Getting Help When F1 is pressed a small help window describing the appropriate key...

Страница 67: ...gives an overview of the basic system information Aptio Setup Utility Copyright C 2013 American Megatrends Inc Main Advanced Chipset Security Boot Save Exit BIOS Information BIOS Vendor American Megat...

Страница 68: ...e CPU The fields in CPU Information cannot be changed The items shown in the system overview include Microcode Patch Installed microcode patch BayTrail SoC CPU stepping level Memory Information The Me...

Страница 69: ...that the settings made are compatible with the hardware Aptio Setup Utility Copyright C 2013 American Megatrends Inc Main Advanced Chipset Security Boot Save Exit ACPI Settings F81866 Super IO Config...

Страница 70: ...END button is pressed Select Screen Select Item EnterSelect Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatr...

Страница 71: ...General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 4 F81866 Super IO Configuration 5 3 2 1 Serial Port n C...

Страница 72: ...tomatically detected IO 3F8h IRQ 4 Serial Port I O port address is 3F8h and the interrupt address is IRQ4 IO 3F8h IRQ 3 4 Serial Port I O port address is 3F8h and the interrupt address is IRQ3 4 IO 2F...

Страница 73: ...F8h and the interrupt address is IRQ3 4 IO 2F8h IRQ 3 4 Serial Port I O port address is 2F8h and the interrupt address is IRQ3 4 IO 3E8h IRQ 3 4 Serial Port I O port address is 3E8h and the interrupt...

Страница 74: ...10 11 IO 2E8h IRQ 10 11 Serial Port I O port address is 2E8h and the interrupt address is IRQ10 11 IO 2F0h IRQ 10 11 Serial Port I O port address is 2F0h and the interrupt address is IRQ10 11 IO 2E0h...

Страница 75: ...s is 3E8h and the interrupt address is IRQ3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port I O port address is 2E8h and the interrupt address is IRQ3 4 5 6 7 9 10 11 12 IO 2F0h IRQ 3...

Страница 76: ...4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port I O port address is 2F8h and the interrupt address is IRQ3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port I O port add...

Страница 77: ...V 12V 12 144 V DDR 1 372 V 5VSB 5 040 V 3 3V 3 344 V 3 3VSB 3 360 V Select Screen Select Item EnterSelect Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Ver...

Страница 78: ...enabled System will wake on the dat hr min sec specified Select Screen Select Item EnterSelect F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save ESC Exit Version 2 16 1242 Copyright C...

Страница 79: ...on allows users to maintain a system remotely by re directing keyboard input and text output through the serial port Aptio Setup Utility Copyright C 2013 American Megatrends Inc Advanced COM1 Console...

Страница 80: ...covery Function Disabled Auto Recovery Function Reboot and recover system automatically within 10 min when OS crashes Please install Auto Recovery API service before enabling this function Select Scre...

Страница 81: ...lities provided by Vanderpool Technology Select Screen Select Item EnterSelect Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2...

Страница 82: ...nable or disable virtualization on the system When combined with third party software Intel Virtualization technology allows several OSs to run on the same system at the same time Disabled DEFAULT Dis...

Страница 83: ...tem EnterSelect Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 11 IDE Configuration Seri...

Страница 84: ...l Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 12 USB Configuration USB Devices The USB Devices Enabled fiel...

Страница 85: ...ing the wrong values for the Chipset BIOS selections in the Chipset BIOS menu may cause the system to malfunction Aptio Setup Utility Copyright C 2013 American Megatrends Inc Main Advanced Chipset Sec...

Страница 86: ...2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 14 North Bridge Configuration 5 4 1 1 Internal IGD Configuration Use the Internal IGD Configuration BIOS Menu 15 menu to set the integrate...

Страница 87: ...d by internal graphics device 128M 128 MB of memory used by internal graphics device 256M DEFAULT 256 MB of memory used by internal graphics device 512M 512 MB of memory used by internal graphics devi...

Страница 88: ...lp F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 16 South Bridge Configuration Restore on AC Power Loss Last State...

Страница 89: ...figure the USB xHCI USB 3 0 controller Enabled Enable the xHCI controller USB 3 0 ports behave as USB 3 0 ports Smart Auto DEFAULT Allow the use of USB 3 0 devices prior to OS boot USB 3 0 ports funct...

Страница 90: ...Configuration PCI E Mini Card Full Size Speed Auto PCI E Mini Card Half Size Speed Auto Configure PCIe Port Speed Select Screen Select Item EnterSelect Change Opt F1 General Help F2 Previous Values F3...

Страница 91: ...ssword and must be entered to boot or enter Setup In Setup the User will have Administrator rights The password must be In the following range Maximum length 3 Minimum length 20 Administrator Password...

Страница 92: ...ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 19 Boot Bootup NumLock State On Use the Bootup NumLock State BIOS option to specify if the number lock setting must be mod...

Страница 93: ...e 1st boot device is a GPT HDD Disabled DEFAULT Disable UEFI boot OS Selection Windows 8 x Use the OS Selection BIOS option to select an operating system OS before installing OS Windows 8 x DEFAULT Th...

Страница 94: ...ble boot option for legacy network devices Disabled DEFAULT Ignore all PXE Option ROMs Enabled Load PXE Option ROMs Option ROM Messages Force BIOS Use the Option ROM Messages option to set the Option...

Страница 95: ...ect Item EnterSelect Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 20 Save Exit Save Ch...

Страница 96: ...age 82 Save as User Defaults Use the Save as User Defaults option to save the changes done so far as user defaults Restore User Defaults Use the Restore User Defaults option to restore the user defaul...

Страница 97: ...PPC F08B F10B BT Panel PC Page 83 6 Interface Connectors Chapter 6...

Страница 98: ...peripheral interface connectors and configuration jumpers The connector locations are shown in Figure 6 1 and Figure 6 2 The Pin 1 locations of the on board connectors are also indicated in the diagra...

Страница 99: ...interface connectors on the AFL3MB2 BT Pinouts of these connectors can be found in the following sections Connector Type Label Battery connector 2 pin wafer BAT1 Digital I O connector 10 pin header D...

Страница 100: ...B 2 0 connector 4 pin wafer HUB_USB2 USB connector 4 pin wafer CAM_USB2 VGA connector 10 pin header VGA_CON1 Webcam connector 4 pin wafer CAM_USB1 Table 6 1 Peripheral Interface Connectors 6 2 1 Batte...

Страница 101: ...INV_CN1 Pinouts 6 2 4 LVDS Connector LVDS1 PIN NO DESCRIPTION PIN NO DESCRIPTION 1 GND 2 GND 3 LVDSA0 4 LVDSA0 5 LVDSA1 6 LVDSA1 7 LVDSA2 8 LVDSA2 9 LVDSACLK 10 LVDSACLK 11 LVDSA3 12 LVDSA3 13 GND 14...

Страница 102: ...hone Connector DMIC1 Pinouts 6 2 7 PCIe Mini Connector Full Size M_PCIE1 PIN NO DESCRIPTION PIN NO DESCRIPTION 1 WAKE 2 VCC3 3 NC 4 GND 5 NC 6 VCC1 5 7 CLKREQ 8 NC 9 GND 10 NC 11 REFCLK0 12 NC 13 REFC...

Страница 103: ...outs 6 2 8 PCIe Mini Connector Half Size M_PCIE2 PIN NO DESCRIPTION PIN NO DESCRIPTION 1 WAKE 2 VCC3 3 Reserved 4 GND 5 Reserved 6 VCC1 5 7 CLKREQ 8 NC 9 GND 10 NC 11 REFCLK1 12 NC 13 REFCLK1 14 NC 15...

Страница 104: ...3 Table 6 9 PCIe Mini Connector M_PCIE2 Pinouts 6 2 9 Power LED Connector PW_LED1 PIN NO DESCRIPTION 1 PW_LED 5V 2 GND 3 SUS PW LED 5V Table 6 10 Power LED Connector PW_LED1 Pinouts 6 2 10 SATA Connec...

Страница 105: ...6 2 12 Speaker Connector CN3 PIN NO DESCRIPTION 1 AUD_OUTL 2 AUD_OUTL 3 AUD_OUTR 4 AUD_OUTR Table 6 13 Speaker Connector CN3 Pinouts 6 2 13 SPI Flash Connector JSPI1 PIN NO DESCRIPTION 1 1 8V 2 SPI_CS...

Страница 106: ...A4 4 GND Table 6 16 USB 2 0 Connector HUB_USB1 Pinouts 6 2 16 USB 2 0 Connector HUB_USB2 PIN NO DESCRIPTION 1 5V 2 DATA3 3 DATA3 4 GND Table 6 17 USB 2 0 Connector HUB_USB2 Pinouts 6 2 17 VGA Connecto...

Страница 107: ...s 6 3 External Interface Panel Connectors The table below lists the rear panel connectors on the AFL2MB 15A motherboard Pinouts of these connectors can be found in the following sections Connector Typ...

Страница 108: ...us 5 N A 14 LINNK1000 3 3sus 6 N A 15 GND 7 MDI2 16 GND 8 MDI2 17 N A 9 MDI3 18 N A Table 6 22 Ethernet Connectors LAN1 LAN2 Pinouts 6 3 2 Power Connector CN5 Table 6 23 Power Connector CN5 Pinouts 6...

Страница 109: ...5 USB 3 0 Connectors USB_CON1 PIN NO DESCRIPTION PIN NO DESCRIPTION 1 5Vsus 10 5Vsus 2 DATA1 11 DATA2 3 DATA1 12 DATA2 4 GND 13 GND 5 SSRX1 14 SSRX2 6 SSRX1 15 SSRX2 7 GND 16 GND 8 SSTX1 17 SSTX2 9 S...

Страница 110: ...Jumpers 6 4 1 Backlight Voltage Selection Jumper J_BL1 PIN DESCRIPTION Short 1 2 3 3 V Default Short 2 3 5 V Table 6 28 Backlight Voltage Selection Jumper J_BL1 Settings 6 4 2 Inverter Power Selectio...

Страница 111: ...PPC F08B F10B BT Panel PC Page 97 6 4 4 Panel PWM Power Selection Jumper J_ADJ1 PIN DESCRIPTION Short 1 2 3 3V Default Short 2 3 5V Table 6 31 Panel PWM Power Selection Jumper J_ADJ1 Settings...

Страница 112: ...PPC F08B F10B BT Panel PC Page 98 Appendix A A Regulatory Compliance...

Страница 113: ...ance with the essential requirements and other relevant provisions of Directive 2014 53 EU Bulgarian IEI Integration Corp 2014 53 EU esky Czech IEI Integration Corp t mto prohla uje e tento za zen je...

Страница 114: ...EU Lietuvi Lithuanian IEI Integration Corp deklaruoja kad is ranga atitinka esminius reikalavimus ir kitas 2014 53 EU Direktyvos nuostatas Nederlands Dutch IEI Integration Corp dat het toestel toeste...

Страница 115: ...o ili direktive 2014 53 EU Slovensky Slovak IEI Integration Corp t mto vyhlasuje e zariadenia sp a z kladn po iadavky a v etky pr slu n ustanovenia Smernice 2014 53 EU Suomi Finnish I I Integration Co...

Страница 116: ...terference at his own expense Federal Communication Commission Interference Statement This equipment has been assembled with components that comply with the limits for a Class B digital device pursuan...

Страница 117: ...mentally Friendly Use Period EFUP This is an estimate of the number of years that these substances would not leak out or undergo abrupt change This product may contain replaceable sub assemblies compo...

Страница 118: ...PPC F08B F10B BT Panel PC Page 104 B BIOS Configuration Options Appendix B...

Страница 119: ...Change Settings Auto 59 Serial Port Enabled 59 Change Settings Auto 59 Serial Port Enabled 60 Change Settings Auto 60 Serial Port Enabled 61 Change Settings Auto 62 Hardware Health Status 63 Wake Syst...

Страница 120: ...er Password 77 Bootup NumLock State On 78 Quiet Boot Enabled 79 UEFI Boot Disabled 79 OS Selection Windows 8 x 79 Launch PXE OpROM Disabled 80 Option ROM Messages Force BIOS 80 Save Changes and Reset...

Страница 121: ...PPC F08B F10B BT Panel PC Page 107 C Safety Precautions Appendix C...

Страница 122: ...event the risk of electric shock make sure power cord is unplugged from wall socket To fully disengage the power to the unit please disconnect the power cord from the AC outlet Refer servicing to qual...

Страница 123: ...ts including the PPC F08B F10B BT Dry climates are especially susceptible to ESD It is therefore critical that whenever the PPC F08B F10B BT is opened and any of the electrical components are handled...

Страница 124: ...e is classified as electronic device in terms of the European Directive 2012 19 EU WEEE and must not be disposed of as domestic garbage EU wide legislation as implemented in each Member State requires...

Страница 125: ...onto any other components To clean the LCD panel gently wipe it with a piece of soft dry cloth or a slightly moistened cloth The interior of the device does not require cleaning Keep fluids away from...

Страница 126: ...evice as they may damage the plastic parts Vacuum cleaner Using a vacuum specifically designed for computers is one of the best methods of cleaning the device Dust and dirt can restrict the airflow in...

Страница 127: ...PPC F08B F10B BT Panel PC Page 113 D Watchdog Timer Appendix D...

Страница 128: ...BIOS function call INT 15H is used to control the Watchdog Timer INT 15H AH 6FH Sub function AL 2 Sets the Watchdog Timer s period BL Time out value Its unit second is dependent on the item Watchdog T...

Страница 129: ...e system resets Example program INITIAL TIMER PERIOD COUNTER W_LOOP MOV AX 6F02H setting the time out value MOV BX 05 time out value is 5 seconds INT 15H ADD THE APPLICATION PROGRAM HERE CMP EXIT_AP 1...

Страница 130: ...PPC F08B F10B BT Panel PC Page 116 Appendix E E Hazardous Materials Disclosure...

Страница 131: ...amps These components will be separately marked Please refer to the following table Part Name Toxic or Hazardous Substances and Elements Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium CR VI Polybro...

Страница 132: ...Panel PC Page 118 RoHS RoHS Pb Hg Cd CR VI PBB PBDE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O SJ T 11363 2006 GB T 26572 2011 X SJ T 11363 2006...

Отзывы: