background image

7

Unpacking

Carton Contents

•  Cordless air compressor
•  Air hose
•  Accessory pack
•  Wrench
•  40 V EcoSharp

®

 battery

•  EcoSharp

®

 battery charger

•  Manuals with registration card

1.  Carefully remove the cordless air compressor and check 

to see that all of the above items are supplied.

2.  Inspect the product carefully to make sure no breakage or 

damage occurred during shipping. If you find damaged or 

missing parts, DO NOT return the unit to the store. Please 

call the Snow Joe

®

 + Sun Joe

®

 customer service center at 

1-866-SNOWJOE (1-866-766-9563

).

  NOTE: Do not discard the shipping carton and packaging 

material until you are ready to use your new cordless 

air compressor. The packaging is made of recyclable 

materials. Properly dispose of these materials in 

accordance with local regulations.

IMPORTANT! The equipment and packaging material are  

not toys. Do not let children play with plastic bags, foils, 

or small parts. These items can be swallowed and pose a 

suffocation risk!

Assembly

m

WARNING!

 To avoid serious personal injury, read and 

understand all safety instructions provided.

Attaching the Air Hose

1.  Pull the air outlet coupler backwards, and insert the air 

hose in (Fig. 1).  

2.  Release the coupler, the air hose will be secured in the air 

outlet (Fig. 2).  

3.  To remove the air hose, pull the air outlet coupler 

backwards and pull out the air hose. 

Battery Pack Operation

The equipment is powered by a lithium-ion battery. The battery 

pack is completely sealed and maintenance free.

Battery Charge Level Indicator

The battery pack is equipped with a push button for checking 

the charge level. Simply press the push button to read off the 

battery charge level from the LEDs of the battery indicator:

•  All 3 level monitoring LEDs are lit: Battery charge level 

 

is high.

•  2 level monitoring LEDs are lit: Battery charge level is 

decreasing. Stop work as soon as possible.

•  1 level monitoring LED is lit: Battery is flat. Stop work 

IMMEDIATELY and charge the battery. Otherwise the 

battery’s service life will be greatly shortened.

NOTE: If the charge level button does not appear to be 

working, place the battery pack on the charger and charge as 

needed.
NOTE: Immediately after using the battery pack, the charge 

level button may display a lower charge than it will if checked 

a few minutes later. The battery cells “recover” some of their 

charge after resting.

Fig. 1

Air outlet

Air hose

Coupler

Fig. 2

Release the 

coupler

Charge level button 

The battery is at 30% capacity 

and requires charging

The battery is at 60% capacity 

and requires charging soon

The battery is at full capacity

Light Indicators

Lights

Содержание iONAIR

Страница 1: ...uding pets should be kept a safe distance away from the work area 4 Do not use the compressor if the switch doesn t turn it on or off any electric appliance that cannot be controlled with the ON OFF switch is dangerous and must be repaired 5 Do not force the tool It will perform better with less likelihood of personal or mechanical injury if it is used at the rate for which it is designed 6 Wear p...

Страница 2: ...rrect handling of the battery pack can cause cell damage IMPORTANT Analyses confirm that incorrect use and poor care of high performance batteries are the main factors responsible for personal and or product damage mWARNING Use only approved replacement batteries other batteries may damage the cordless air compressor and cause it to malfunction which can lead to serious personal injury mCAUTION To...

Страница 3: ...emperatures may exceed 104ºF 40ºC such as in direct sunlight or inside a vehicle or metal building during the summer Information about the battery 1 The battery pack supplied with your cordless air compressor is only partially charged The battery pack has to be charged completely before you use the tool for the first time 2 For optimum battery performance avoid low discharge cycles by charging the...

Страница 4: ...posed to heat during the charging process as the battery cells may have suffered dangerous damage 11 Do not use batteries that have suffered curvature or deformation during the charging process or those that exhibit other atypical symptoms gassing hissing cracking etc 12 Never fully discharge the battery pack maximum recommended depth of discharge is 80 A complete discharge of the battery pack wil...

Страница 5: ...not touch the pump the manifold or the transfer tube while the compressor is running Allow the parts to cool down before handling or servicing RISK OF FIRE OR EXPLOSION Do not spray a flammable or combustible liquid or paint near sparks flames pilot lights or in a confined area The spray area must be well ventilated Keep compressor at least 20 6 m away from spray area Never smoke when spraying Ind...

Страница 6: ...pacity 4 0 Ah Charging Time 2 5 3 hours for full charge Battery Run Time Max 65 min Working Pressure 85 115 PSI 6 8 Bar Air Flow 0 7 SCFM at 90 PSI Load Current Max 5 5 A Air Tank Volume 1 6 Gal 6 1 L Hose Length 25 ft 7 6 m Weight air compressor only 16 9 lbs 7 7 kg Weight air compressor with battery 19 6 lbs 8 9 kg FRONT BACK 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 19 20 21 22 23 24 25 13 Batt...

Страница 7: ...e air hose will be secured in the air outlet Fig 2 3 To remove the air hose pull the air outlet coupler backwards and pull out the air hose Battery Pack Operation The equipment is powered by a lithium ion battery The battery pack is completely sealed and maintenance free Battery Charge Level Indicator The battery pack is equipped with a push button for checking the charge level Simply press the pu...

Страница 8: ...ck You can top off your battery pack s charge before starting a big job or after a long day of use Charging the Battery 1 Pull the push lock button on the battery to pull the battery pack up and out of the equipment Fig 3 2 Check that the mains voltage is the same as that marked on the rating plate of the battery charger Then insert the charger s plug into the electrical wall outlet When you plug ...

Страница 9: ... the equipment s power IMPORTANT Never allow the battery pack to become fully discharged as this will cause irreversible damage to the battery Charging a Hot or Cold Battery Pack A red and green flashing indicator light on the charger indicates that the battery pack temperature is outside the charging range Once the pack is within the acceptable range normal charging will take place and the red li...

Страница 10: ...uild the tank air between 85 PSI and 115 PSI The unit cannot work properly with the tank pressure lower than 85 PSI If the tank pressure is higher than 130 PSI the safety valve will automatically trigger to release air mWARNING High temperatures are generated by the electric motor and the pump To prevent burns or other injuries DO NOT touch the air compressor while it is running Allow it to cool b...

Страница 11: ...sired pressure DO NOT exceed safety working pressure of the product that is being inflated NOTE The output air pressure cannot be set higher than the tank pressure 2 If the air blow gun is attached press down on the air blow gun switch to release the air Fig 16 Accessory Usage Teflon tape Use to wrap every screw on thread to ensure a proper seal Metal connection Connected with the air blow gun Use...

Страница 12: ...nk mWARNING Allow the unit to cool before draining the tank The air tank drain valve will become hot during operation 1 Press the On Off switch on the Off O side and remove the battery Turn the pressure regulator knob counter clockwise to set the outlet pressure to zero 2 Pull out the safety valve to release the air in the air tank until the air tank pressure reaches zero Fig 17 3 Place a suitable...

Страница 13: ...re or explosion mWARNING To reduce the risk of injury or explosion never burn or incinerate a battery pack even if it is damaged dead or completely discharged When burned toxic fumes and materials are emitted into the surrounding atmosphere 1 Batteries vary according to device Consult your manual for specific information 2 Install only new batteries of the same type in your product where applicabl...

Страница 14: ...frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to t...

Страница 15: ...urs for full charge Battery Run Time Max 65 min EcoSharp PRO 40 V 5 0 Ah Lithium Ion Battery Charging Time 3 3 5 hours for full charge Battery Run Time Max 80 min EcoSharp 40 V Lithium Ion Battery Charger iBAT40 iBAT40XR iCHRG40 Model Accessories Item 1 2 3 EcoSharp PRO 40 V 6 0 Ah Lithium Ion Battery Charging Time 4 5 hours for full charge Battery Run Time Max 95 min iBAT40XRP 4 5 EcoSharp 40 V L...

Страница 16: ...NOTES 16 ...

Страница 17: ...NOTES 17 ...

Страница 18: ...NOTES 18 ...

Страница 19: ... the owner s manual Snow Joe Sun Joe will not be responsible for the cost of any unauthorized warranty repairs This warranty does not cover any cost or expense incurred by the purchaser in providing substitute equipment or service during reasonable periods of malfunction or non use of this product while waiting for a replacement part or unit under this warranty Wearing parts like belts augers chai...

Страница 20: ... California to cause cancer birth defects or other reproductive harm Some examples of these chemicals are lead from lead based paints crystalline silica from bricks and cement and other masonry products and arsenic and chromium from chemically treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a we...

Отзывы: