background image

5000 Watt Power Inverter 
Model 11155 

5000 Watt Power Inverter 

12V-DC to 110V-AC 

5000 Watt Continuous 

10 000 Watt High Surge 

 

Thank You for Purchasing the 5000W Power Inverter 

For the most beneficial, efficient operation, and long term use from your new inverter, please read carefully 

the information and explanation of features contained in this manual. You are also advised to keep this 

manual in a safe place for ready reference. 

 

These inverters lead the field in power inverters and set the pace in development and design. They have been 

meticulously assembled to provide reliable service, converting low voltage, direct current (DC) to 110-120 volt 

alternating household current (AC).  

 

 

CAUTION: WORKING WITH BATTERIES 

To reduce the risk of battery explosion, follow all instructions of the battery manufacturer and all 
manufacturer instructions of additional components.  
 
RISK OF EXPLOSIVE GAS – Working in the vicinity of a lead acid battery is dangerous.  Lead acid 
batteries contain hydrogen-oxygen gases that can cause explosion and sulfuric acid that can cause severe 
burns.  Always work in a well ventilated area.   
DO NOT SMOKE, OR ALLOW A SPARK OR A FLAME IN THE VICINITY OF A BATTERY! 
Remove personal metal items such as rings, necklaces, watches, and bracelets when working with a 
battery.  Be extra cautious to reduce risk of dropping a metal tool on to the battery.  The battery may spark 
or short circuit. 
NEVER CHARGE A FROZEN BATTERY  
 
If battery acid contacts skin or clothing, wash immediately with soap and water.  If acid enters the eye, 
IMMEDIATELY FLOOD EYE WITH RUNNING COLD WATER for at least 10 minutes.  GET MEDICAL 
ATTENTION IMMEDIATELY. 
 
Failure to comply with above warnings may lead to explosion, and or severe injury. 
 

  Do not expose the inverter to moisture, including rain, snow, spray mist, or excessive 

humidity. To reduce risk of fire hazard, do not cover or obstruct the ventilation openings. Do 
not install the inverter in a non ventilated space. Overheating may result. 

  Use appropriates cables and attachments.  To avoid a risk of fire and electric shock, make 

sure that existing wiring is in good electrical condition; and that wire size is not undersized.  
Do not use damaged or low grade wires.  To ensure adherence to proper electrical wiring 
regulations all wiring must be done by a certified technician or electrician.   

  Do not use inverter if it has been dropped or damaged. 

   Do not attempt to repair or disassemble the inverter.  Risk of shock and fire.  Any 

alterations to the inverter will render the warranty void. 

  Disconnect the inverter from all connections before performing any maintenance on any of 

the equipment, such as changing a fuse on the inverter. 

  The inverter must be grounded.   Grounding and all other wiring must comply with local 

codes and ordinances.  Grounding may be made to the chassis of most vehicles or to an 
earth ground.  Make sure the inverter is off before attempting to ground.  Operating an 
inverter that is not properly grounded may result in electrical shock. 

  Reverse polarity connection will result in a blown fuse and may cause permanent damage 

to the inverter and will void warranty 

  Making the connection between the Positive Terminals may cause a spark as a result of 

current flowing to charge capacitors within the inverter. This is a normal occurrence. Due to 

Содержание 5000 Watt POWER INVERTER

Страница 1: ...5000 Watt POWER INVERTER ONDULEUR DE PUISSANCE 5000 Watt INVERSOR de 5000 Watt User s Manual Notice D utilisation Manual del Usario...

Страница 2: ...FLOOD EYE WITH RUNNING COLD WATER for at least 10 minutes GET MEDICAL ATTENTION IMMEDIATELY Failure to comply with above warnings may lead to explosion and or severe injury Do not expose the inverter...

Страница 3: ...lculate most starting loads Starting Load 2 x WATTAGE In general the start up load of the appliance or power tool determines whether your inverter has the capability to power it To calculate the conti...

Страница 4: ...e of the power source When the voltage reading does not fall within this range check the connection of the wires to terminals on the power source and on the inverter Also check the voltage of the powe...

Страница 5: ...to Connect the Inverter 1 Make sure the ON OFF rocker switch see diagram part A is in the OFF 0 position 2 Connect the BLACK cable to the BLACK negative power input terminal see diagram part F of you...

Страница 6: ...hat the antenna cable is adequately shielded and of good quality 2 Try altering the positions of the inverter antenna cables and television power cord 3 Add an extension cord from the inverter to the...

Страница 7: ...conversion 5000 Watt Power Inverter The modified sine wave inverter has a root mean square RMS voltage of 110 volts but most AC voltmeters are calibrated to measure pure sine waves for their RMS volt...

Страница 8: ...ance Inverter is too hot causing thermal overload Shut off inverter to allow cooling Ensure proper ventilation Red LED on Inverter may be defective Contact tech hotline Electrical interference from th...

Страница 9: ...load Temperature Yes Short Circuit Protection Yes Physical Dimensions 16 x 8 4 x 7 8 40 5 cm x 21 3 cm x 20 cm Weight appro 23 15 lbs 10 5 kg LIMITED WARRANTY This product is covered by a one year lim...

Страница 10: ...e oxyg ne pouvant causer des explosions De plus elles contiennent de l acide sulfurique pouvant causer des br lures graves Assurez vous que l environnement dans lequel vous travaillez est bien a r NE...

Страница 11: ...eut g n rer des tincelles caus es par le courant de charge des condensateurs internes de l onduleur Ceci est normal Consid rant ce risque d tincelles il est extr mement important que l onduleur et la...

Страница 12: ...peut tre tr s dangereuse L utilisation incorrecte de votre onduleur peut r sulter en des dommages mat riaux des blessures personnelles et mortelles A Interrupteur bascule ON OFF MARCHE ARR T B C Voya...

Страница 13: ...nsion de la source d alimentation Finalement assurez vous que le voyant DEL Over Temperature Surchauffe et Over Load Surcharge n est pas allum D Quatre prises de courant de 110 VCA ordinaires Am rique...

Страница 14: ...la source de 12 volts Lorsqu une rallonge est utilis e entre l onduleur et un appareil assurez vous qu elle n exc de pas 50 pieds 15 2 m tres cette distance le risque de chute de tension est limit Ca...

Страница 15: ...ut r sulter en un incendie ou une explosion Mise la masse de l onduleur Localisez la borne de mise la masse de l onduleur Acheminez un fil de calibre 0 de la borne de la mise la masse un point de mass...

Страница 16: ...ternes exc de 165 F 74 C Attention L onduleur de puissance de 5 000 watts est quip d un ventilateur Si le ventilateur est incapable de maintenir la temp rature un niveau qui assure un fonctionnement s...

Страница 17: ...que l onduleur n est pas pr s de sources potentielles de vapeurs ou de gaz inflammables avant de raccorder l onduleur la source d nergie Assurez vous que la consommation lectrique de l appareil ou de...

Страница 18: ...l viseur Interf rence avec le t l viseur Le signal de la t l vision est trop faible Essayez un autre t l viseur Diff rentes marques et mod les op rent diff remment lorsque des interf rences existent T...

Страница 19: ...Dimensions 16 x 8 4 x 7 8 40 6 x 21 3 x 19 8 cm Poids Environ 23 15 lb 10 5 kg GARANTIE LIMIT E Ce produit est couvert par une garantie limit e d un an Sunforce Products Inc garantit l acheteur initi...

Страница 20: ...AL MEDICO INMEDIATAMENTE El no seguir las precauciones anteriores puede provocar una explosi n o da os muy importantes No exponga el inversor a humedad incluyendo lluvia nieve roc o o humedad excesiv...

Страница 21: ...apacidad de suministrar suficiente energ a Para calcular la carga continua igual que el vataje en la f rmula de m s arriba Carga continua A amperios x 110 tensi n CA Atenci n Realice siempre una prueb...

Страница 22: ...l inversor Da os causados por exceso de tensi n no est n cubiertos por la garant a Cuando encienda el inversor ON el gr fico de tensi n muestra entre 10 y 15 V dependiendo de la tensi n de la fuente d...

Страница 23: ...tilizar un cable de extensi n desde el inversor aseg rese que el cable de extensi n no es m s largo que 50 pies 15 m No deber a de haber riesgo de p rdida de energ a con esta longitud Di metro de los...

Страница 24: ...esta conexi n a Tierra tirando el cable a un suelo de tierra Antes de conectar la tierra aseg rese que el inversor est apagado Hacer funcionar el inversor sin conexi n adecuada a tierra puede provoca...

Страница 25: ...funcionar o cualquier otra superficie que pueda estar en contacto con cualquier fuente de energ a est n mojados El agua y muchos otros l quidos pueden ser conductores de electricidad lo que puede pro...

Страница 26: ...o en marcha durante aprox 20 minutos para recargar la bater a Si oye una alarma continua o apagado autom tico i Apague inmediatamente el inversor ii No vuelva a arrancar el inversor hasta que el orige...

Страница 27: ...no experimentar las mismas interferencias Tensi n de entrada inferior a 10 V Recargue o sustituya la bater a Puede que sea necesario el uso de dos bater as para hacer funcionar algunos aparatos Alarma...

Страница 28: ...tada Sunforce Products Inc garantiza al comprador original que este producto est libre de defectos de funcionamiento y de defectos en materiales y mano de obra durante un per odo de una a o a partir d...

Страница 29: ......