Frequently Ordered Parts

 

 

The following is a list of parts that are frequently ordered for self replacement and repairs.  To 
aid you in ordering parts, please use the provided product numbers given below for each part.  
The replacement of some parts not listed here may require sending in the unit to the 
manufacturer for repairs.   
 
 
 
 
 
 
 

Product # 

95071 

 
 
 
 
 
 
 

Product # 

96065 

Black Connector

 – 

Connects from mattress 
to blower unit side panel.  
Allows air movement to 
inflate mattress.

Filters

 – Removes dust 

and other particles from 
the air as it is pulled into 
the blower unit. 

 

Product # 

96066 

 
 
 
 
 
 

Product # 

96064 

Male CPC (Chrome)

 –

Attached to blower unit 
side panel.  Connects to 
Female CPC to remove 
exhaust air from unit to 
mattress. 

Female CPC

 – Connects 

from mattress to Male 
CPC on blower unit.  
Removes exhaust air 
from unit to mattress. 

 
 

Product # 

95031 

 
 
 
 
 
 

Product # 

96055 

Power Cords 
(removable and fixed)

 – 

Grounded power cord for 
providing power to the 
blower unit. 

Hooks 

– Collapsible 

hooks that allow the unit 
to be hung on bed frame. 

 
 

Product # 

N/A 

 

Brackets 

– Attach the 

hooks to the bottom case 
of the unit. 

 
 
 
 
 
 
 
 

10 

Содержание SAPPHIRE 1100

Страница 1: ...USER INSTRUCTION MANUAL SAPPHIRE SERIES 1100 1100EC Read Entire Manual Before Operating Device OI S1100401 401 5 Uncontrolled Document Rev 6 0 06 23 2006 1 ...

Страница 2: ...ings and Precautions 3 Purposes of the Device 3 Description of the Device 4 Unpacking Parts Breakdown 4 Operating Instructions 5 Key Pad Quick Reference 7 Mattress and Blower Unit Cleaning 8 Maintenance 9 Storage 9 Troubleshooting 9 Frequently Ordered Parts 10 Return Exchange Goods Policy 11 Warranty Provisions 11 Technical Description of the Equipment The two principle components of the Sunflower...

Страница 3: ...tive component that has contact with the patient is a specialized multi cell air mattress sized to fit a standard medical bed frame The air mattress serves to replace the original mattress and is equipped with 4 air hoses with connectors that mate with the Air Blower Control Unit The Control Unit is a self contained totally enclosed module that hangs by retractable hooks on the bed frame at the fo...

Страница 4: ...ess Cover True Low Air Loss Mattress and Cover Tools Required NONE Unpacking instructions Remove the products from the packing material and examine for shipping damage If damage is detected in shipping contact the freight company and file a damage complaint immediately Directions for Mattress Placement Replace the existing bed mattress with True Low Air Loss Mattress Secure Air Mattress to the bed...

Страница 5: ...NOT lay control unit on its back Air Tubing Connection CPC 5 Attach the air tubing to the blower unit being sure it snaps in tight Be sure air tubing is not kinked and is unobstructed 6 Plug unit into grounded A C 110 volt outlet 7 Turn master power switch located on the side of the unit on 8 At this time the control unit will automatically go into static mode 9 Press the Autofirm button for quick...

Страница 6: ...inutes if there are no changes to the blower settings the lockout feature will activate b Press and hold the Lock out button for 5 seconds to disengage the lock out feature 15 For quick deflation or for CPR use a Turn power off b Twist CPR plug to open it c Remove the hoses from the control unit Notice The mattress is equipped with a 2 inch foam pad in the mattress base for patient support and tra...

Страница 7: ...L ILLUSTRATION Refer to this page as needed for quick reference to the control panel functions Shows control panel layout for the blower unit Provides individual button illustration and function description For more detailed directions refer back to the operating instructions starting on page 5 FOR INQUIRIES CALL 1 888 321 3382 Cycle Time Increases or decrease the time of cycle between 3 to 20 min...

Страница 8: ...ent with diluted bleach in cold water 10 minutes b Main wash for 15 minutes Time depending on soil level c Rinse Cycle 5 minutes minimum d Spin Drain Cycle 5 minutes minimum e Air dry or place in dryer at very low or no heat 8 After the cover interior sacs and base are dry store them in a sterilized bag and seal for next use Notice DO NOT use water temperatures greater than 150 F 65 C BLOWER CLEAN...

Страница 9: ...p mattress in a clean dry area away from heat or flames The filter is easily removed and reinserted through the gap in the back housing TROUBLE SHOOTING GUIDE If mattress is not inflating Make certain none of the hoses are punctured kinked or disconnected Check for proper connections from the hoses to the pump Make sure they are secure Check or clean intake filters Be sure CPR valve is closed If t...

Страница 10: ... movement to inflate mattress Filters Removes dust and other particles from the air as it is pulled into the blower unit Product 96066 Product 96064 Male CPC Chrome Attached to blower unit side panel Connects to Female CPC to remove exhaust air from unit to mattress Female CPC Connects from mattress to Male CPC on blower unit Removes exhaust air from unit to mattress Product 95031 Product 96055 Po...

Страница 11: ...be completed and then items will be replaced or repaired at no cost WARRANTY PROVISIONS Warranty Sunflower Medical LLC Warrants that all products provided under this agreement are free from defects in material and workmanship for the following stated warranty period from the date of delivery Sunflower Medical LLC guarantees all purchased equipment to be free from defects in material and workmanshi...

Отзывы: