(fig. 10a-b-c) and upper-lower (fig. 10d) protective guards assembly.
CONTROL UNIT
The board is housed in a ip64 water-tight container; connect the motor and temperature probe to this
board.
A green LED (voltage present) and a red LED indicating the operating mode, light-up when the con-
trol unit is switched on:
√ Permanent red LED ------- AUTOMATIC
√ Flashing red LED ------- MANUAL
The control unit has a pushbutton panel to manually control the system and a jumper for choosing
automatic or manual mode.
1) 1) Connect the motor to specific terminal box (see connection diagram).
2) Choose the temperature range by setting the SW1 deep switch.
3) Connect power supply. (without powering)
4) Connect the probe.
5) Select manual mode.
6) Power the board.
7) Adjust the end run points (set in factory) ONLY IF REQUIRED.
8) Select automatic mode.
Probe type: Ntc 100 kohm a 25°C
ATTACHMENT