CONTROL UNIT ADJUSTMENT
AUTOMATIC/MANUAL SWITCH:
Switch positioning in manual: the motor is moved using the buttons;
the red LED in the board flashes.
Switch positioning in automatic: permanent red LED, the motor cannot
be moved using the buttons.
Attention: the buttons are of “dead man” type, if kept pressed the mo-
tor moves, released it stops.
TEMPERATURES SETTING
The temperature is adjusted using Deep Switch SW1 with many combinations, to each corresponds
a temperature minimum and maximum with 20° offset, except one combination where the offset is
25°C (Max 110° Min 85°).
The control unit is by default set
on min 65° - max 85° range
N.B. The temperature range is chosen based on the probe location within the solar system (collector, boiler, etc...).
1
2
3
Min. (°C)
Max. (°C)
on
on
on
55
75
on
on
off
60
80
on
off
on
65
85
on
off
off
70
90
off
on
on
75
95
off
on
off
80
100
off
off
on
85
105
off
off
off
85
110