background image

Vite DIN 912 A2 M8 x 

l

3

Introduction of cover and motor on upper plate and backplate.

Fig. 6

Fig. 7 

 

 

 

Before the subsequent step, connect the control unit (see attachment A, 

page 8) and manually lower the cover against the lower end run (covered 

collector).

 
 

Don’t unroll solar cover by hand, in order to keep limit switches functionality  

 

which are set in factory.

 

Unroll solar cover only eletrically.

 

OK!

5

Содержание TENDAEVO 1T

Страница 1: ...lar collectors INSTALLATION MANUAL www sunergsolar com SUNERGSOLARS r l ViaDonini 51 Loc Cinquemiglia Citta diCastello PG Italy Tel 39075 8540018 Fax 390758648105 info sunergsolar com TENDAEVO_1T TENDAEVO_1TX TENDAEVO_2T TENDAEVO_2TX ...

Страница 2: ...e must be observed and all protections such as anti fall protections safety nets for scaffolding overalls with safety or restraining belts etc must be realised before assembling the structure The used equipment must also be conform with current standards Always wear protective goggles safety shoes cut resi stant gloves and helmet during work TENDAEVO_1T and TENDAEVO_1TX models ore not compatible w...

Страница 3: ... the collector s frame Fig 2 and Fig 3 Fig 1 INSTALLATION METHOD ATTENTION THE EVO SOLAR COVER CAN ONLY BE INSTALLED WITH SO LAR COLLECTORS H1T AND H1TX 2 1 Left upper backplate Right upper plate Left lower backplate Left lower backplate ...

Страница 4: ...Fig 2 Fig 3 3 ...

Страница 5: ...2 Roller spring introduction on lower plate and backplate C Fig 5 A B ATTENTION Insert the safety pin to lock the spring C Fig 4 4 ...

Страница 6: ... 7 Before the subsequent step connect the control unit see attachment A page 8 and manually lower the cover against the lower end run covered collector Don t unroll solar cover by hand in order to keep limit switches functionality which are set in factory Unroll solar cover only eletrically OK 5 ...

Страница 7: ...oning belts 6 Fig 9 Fig 8 MODEL H1T Make 5 6 rotations to perfectly load the roller spring MODEL H1TX Make 5 6 rotations to perfectly load the roller spring ATTENTION keep the loaded roller spring locked during fastening of the tensio ning belts OK x 5 6 ...

Страница 8: ...er lower fig 10d protective guards assembly Fig 10 a b c d OK The cover is now assembled Make the electric connection 7 If lateral guards holes don t metch with backplate and plate holes please drill guards and make a slot ...

Страница 9: ...NUAL The control unit has a pushbutton panel to manually control the system and a jumper for choosing automatic or manual mode 1 1 Connect the motor to specific terminal box see connection diagram 2 Choose the temperature range by setting the SW1 deep switch 3 Connect power supply without powering 4 Connect the probe 5 Select manual mode 6 Power the board 7 Adjust the end run points set in factory...

Страница 10: ...r closing motor BLACK wire 8 Switch input Cover opening OPTIONAL NOT INCLUDED 9 Switch input Cover closing OPTIONAL NOT INCLUDED 10 Common switch input OPTIONAL NOT INCLUDED 11 12 Manual Automatic switch input OPTIONAL NOT INCLUDED 13 14 Probe input 9 Not included and optional wiring Connect the electric motor earth cable directly to power supply earth cable ...

Страница 11: ...tch input Cover closing OPTIONAL NOT INCLUDED 10 Common switch input OPTIONAL NOT INCLUDED 11 12 Manual Automatic switch input OPTIONAL NOT INCLUDED 13 14 Probe input Clamps Description 1 4 7 10 Cover opening M1 M2 M3 M4 brown 2 5 8 11 Common motor M1 M2 M3 M4 blue 3 6 9 12 Cover closing M1 M2 M3 M4 black 13 14 15 Additional board wiring Already wired CONNECTION WITH 4 MOTOR CONTROL UNIT Not inclu...

Страница 12: ...Model Aut Man Switch Deep Switch SW1 Adjustment buttons Probe input 230V 50Hz Power Supply Cover motor inputs External adjustment switches 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Aut Man external switch Not included and optional wiring ...

Страница 13: ...ontrol Switch Probe Input 230V 50Hz Power Supply Motor 1 1 2 3 4 5 6 7 8 9 10 11 12 External adjustment switches Aut Man external switch GRAPHIC DESCRIPTION Centenda 4 Model 12 Motor 2 Motor 3 Motor 4 Not included and optional wiring ...

Страница 14: ...ATURES SETTING The temperature is adjusted using Deep Switch SW1 with many combinations to each corresponds a temperature minimum and maximum with 20 offset except one combination where the offset is 25 C Max 110 Min 85 The control unit is by default set on min 65 max 85 range N B The temperature range is chosen based on the probe location within the solar system collector boiler etc 1 2 3 Min C M...

Страница 15: ...heck the cover is effectively closed the control is given 3 times every 30 minutes The temperature must at least drop below 65 C for the processor to consider the alarm reset When below 65 C the processor considers the alarm reset and activates the relay output for the ascent and keeps it active for 2 minutes The processor will always control an ascent run ignoring the detected temperature when sw...

Страница 16: ...e must be implemented ONLY IF set adjustment is incorrect Lower end run regulator covered collector Upper end run regulator uncovered collector IT IS ESSENTIAL to be able to stop movement at any time during the end run adjustment to avoid damaging property persons animals and the device 15 ...

Страница 17: ...g button until it stops Check whether the stopping point is correct if not repeat the previous operations until it is PLACE THE AUT MAN DIVERTER ON MANUAL ROTATE THE REGULATOR ANTI CLOCKWISE THE COVER IS EXCESSIVELY UNROLLED Press the cover winding button for a few se conds If during covering the cover is excessively unrolled for ming bumps folds etc follow the instructions below Press the cover u...

Страница 18: ...ess the cover winding button until it stops Check whether the stopping point is correct if not repeat the previous operations until it is Place the AUT MAN diverter on Manual ROTATE THE REGULATOR ANTI CLOCKWISE THE COVER IS EXCESSIVELY ROLLED Press the cover unwinding button for a few seconds If the cover is excessively rolled forcing the motor follow the instructions below Press the cover winding...

Страница 19: ...__________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ _________________________...

Страница 20: ...www sunergsolar com SUNERGSOLARS r l ViaDonini 51 Loc Cinquemiglia Citta diCastello PG Italy Tel 39075 8540018 Fax 390758648105 info sunergsolar com Rev 18_00_05_IG ...